Related papers: Recent GasPM advances: photon-feedback mitigation …
Recent developments in photo-detectors and photo-detector systems are reviewed. The main emphasis is made on Silicon Photo-Multipliers (SiPM) - novel and very attractive photo-detectors. Their main features are described. Properties of…
The barrel section of the novel MIP Timing Detector (MTD) will be constructed as part of the upgrade of the CMS experiment to provide a time resolution for single charged tracks in the range of $30-60$ ps using LYSO:Ce crystal arrays read…
Space missions require lightweight, low-power consuming, radiation-tolerant components. Silicon photomultipliers are increasingly used for detecting near-UV, optical, and infrared light in space due to their compact design, low cost, low…
PICOSEC Micromegas (MM) is a precise timing gaseous detector based on a Cherenkov radiator coupled with a semi-transparent photocathode and an MM amplifying structure. The detector conceprt was successfully demonstrated through a…
Gas Electron Multipliers (GEM) are an interesting technology under consideration for the future upgrade of the forward region of the CMS muon system, specifically in the $1.6<| \eta |<2.4$ endcap region. With a sufficiently fine…
We have developed a custom amplifier board coupled to a large-format 16-channel Hamamatsu silicon photomultiplier device for use as the light sensor for the electromagnetic calorimeters in the Muon g-2 experiment at Fermilab. The…
Currently the standard light sensors for imaging atmospheric Cherenkov telescopes are the classical photo multiplier tubes that are using bialkali photo cathodes. About eight years ago we initiated an improvement program with the Photo…
Balloon- and space-borne cosmic-ray experiments employ plastic scintillators read out by silicon photomultipliers (SiPMs) to achieve picosecond-level time resolutions for triggering and particle identification. The performance of these…
A real-time beam profile monitoring system is proposed for GeV photon beams at the BM4 beamline of the Mikamine site, Research Center for Accelerator and Radioisotope Science (RARiS; previously known as ELPH) at Tohoku University. This…
The $\upmu$RWELL-PICOSEC detector, which combines a $\upmu$RWELL gaseous amplification structure with a Cherenkov radiator and photocathode, is a novel approach to acheive fast and precise timing in gaseous detectors. With timing precision…
Among the main disadvantages of using silicon photomultipliers (SiPMs) in large experiments are their limited physical area (increasing the cost and the complexity of the readout of a camera) and their sensitivity to unwanted wavelengths.…
To meet the need for a high counting rate and high time resolution in future high-energy physics experiments, a prototype of a gas photodetector with an RPC structure was developed. Garfield++ simulated the detector's performance, and the…
Aiming to measure the difference in arrival times of two coincident gamma-photons with an accuracy in the order of 200 ps, time-of-flight positron emission tomography systems commonly employ silicon photomultipliers (SiPMs) and…
The advent of silicon photomultipliers has enabled big advances in high energy physics instrumentation, for example by allowing the construction of extremely granular hadronic calorimeters with photon sensors integrated into small…
We present a 'digital SiPM' photo-detection chip combining single photon sensitive avalanche photo diodes and CMOS readout electronics on a single die. The chip has a size of $8046\times9032\,\mu m^2$ with $72.5\%$ of photo sensitive area.…
The combination of plastic scintillators with Silicon Photo-Multipliers (SiPMs) is widely used for detecting radiation in high-energy astrophysics, particle physics, neutrino physics, or medical physics. An example of application for this…
Hyper-Kamiokande, the next generation large water Cherenkov detector in Japan, is planning to use approximately 80,000 20-inch photomultiplier tubes (PMTs). They are one of the major cost factors of the experiment. We propose a novel…
Silicon-based photosensors (SiPMs) working in the Geiger-mode represent an elegant solution for the readout of particle detectors working at low-light levels like Cherenkov detectors. Especially the insensitivity to magnetic fields makes…
The PICOSEC Micromegas detector is a~precise-timing gaseous detector based on a~Cherenkov radiator coupled with a~semi-transparent photocathode and a~Micromegas amplifying structure, targeting a~time resolution of tens of picoseconds for…
Photomultiplier tubes (PMTs) are widely used in astroparticle physics experiments to detect light flashes (e.g. fluorescence or Cherenkov light) from extensive air showers (EASs) initiated by statistically rare very high energy cosmic…