English
Related papers

Related papers: Recent GasPM advances: photon-feedback mitigation …

200 papers

Silicon Photomultipliers (SiPMs) are state-of-the-art photon detectors used in particle physics, medical imaging, and beyond. They are sensitive to individual photons in the optical wavelength regime and achieve time resolutions of a few…

Silicon Photomultipliers (SiPMs) are the state-of-the-art technology in single-photon detection with solid-state detectors. Single Photon Avalanche Diodes (SPADs), the key element of SiPMs, can now be manufactured in CMOS processes,…

A novel concept for ion blocking in gas-avalanche detectors was developed, comprising cascaded micro-hole electron multipliers with patterned electrodes for ion defocusing. This leads to ion blocking at the 10^{-4} level, in DC mode, in…

Instrumentation and Detectors · Physics 2009-05-02 A. V. Lyashenko , A. Breskin , R. Chechik , J. M. F. Dos Santos , F. D. Amaro , J. F. C. A. Veloso

The application of silicon photomultiplier (SiPM) technology for weak-light detection at a single photon level has expanded thanks to its better photon detection efficiency in comparison to a conventional photomultiplier tube (PMT). SiPMs…

A large Time Projection Chamber is the main device for tracking and charged-particle identification in the ALICE experiment at the CERN LHC. After the second long shutdown in 2019/20, the LHC will deliver Pb beams colliding at an…

Instrumentation and Detectors · Physics 2018-07-16 M. M. Aggarwal , Z. Ahammed , S. Aiola , J. Alme , T. Alt , W. Amend , A. Andronic , V. Anguelov , H. Appelshäuser , M. Arslandok , R. Averbeck , M. Ball , G. G. Barnaföldi , E. Bartsch , R. Bellwied , G. Bencedi , M. Berger , N. Bialas , P. Bialas , L. Bianchi , S. Biswas , L. Boldizsár , L. Bratrud , P. Braun-Munzinger , M. Bregant , C. L. Britton , E. J. Brucken , H. Caines , A. J. Castro , S. Chattopadhyay , P. Christiansen , L. G. Clonts , T. M. Cormier , S. Das , S. Dash , A. Deisting , S. Dittrich , A. K. Dubey , R. Ehlers , M. Engel , F. Erhardt , N. B. Ezell , L. Fabbietti , U. Frankenfeld , J. J. Gaardhøje , C. Garabatos , P. Gasik , Á. Gera , P. Ghosh , S. K. Ghosh , P. Glässel , O. Grachov , A. Grein , T. Gunji , H. Hamagaki , G. Hamar , J. W. Harris , P. Hauer , J. Hehner , E. Hellbär , H. Helstrup , T. E. Hilden , B. Hohlweger , M. Ivanov , M. Jung , D. Just , E. Kangasaho , R. Keidel , B. Ketzer , S. A. Khan , S. Kirsch , T. Klemenz , S. Klewin , A. G. Knospe , M. Kowalski , L. Kumar , R. Lang , R. Langoy , L. Lautner , F. Liebske , J. Lien , C. Lippmann , H. M. Ljunggren , W. J. Llope , S. Mahmood , T. Mahmoud , R. Majka , P. Malzacher , A. Marín , C. Markert , S. Masciocchi , A. Mathis , A. Matyja , M. Meres , D. L. Mihaylov , D. Miskowiec , J. Mitra , T. Mittelstaedt , T. Morhardt , J. Mulligan , R. H. Munzer , K. Münning , M. G. Munhoz , S. Muhuri , H. Murakami , B. K. Nandi , H. Natal da Luz , C. Nattrass , T. K. Nayak , R. A. Negrao De Oliveira , M. Nicassio , B. S. Nielsen , L. Oláh , A. Oskarsson , J. Otwinowski , K. Oyama , G. Paić , R. N. Patra , V. Peskov , M. Pikna , L. Pinsky , M. Planinic , M. G. Poghosyan , N. Poljak , F. Pompei , S. K. Prasad , C. A. Pruneau , J. Putschke , S. Raha , J. Rak , J. Rasson , V. Ratza , K. F. Read , A. Rehman , R. Renfordt , T. Richert , K. Røed , D. Röhrich , T. Rudzki , R. Sahoo , S. Sahoo , P. K. Sahu , J. Saini , B. Schaefer , J. Schambach , S. Scheid , C. Schmidt , H. R. Schmidt , N. V Schmidt , H. Schulte , K. Schweda , I. Selyuzhenkov , N. Sharma , D. Silvermyr , R. N. Singaraju , B. Sitar , N. Smirnov , S. P. Sorensen , F. Sozzi , J. Stachel , E. Stenlund , P. Strmen , I. Szarka , G. Tambave , K. Terasaki , A. Timmins , K. Ullaland , A. Utrobicic , D. Varga , R. Varma , A. Velure , V. Vislavicius , S. Voloshin , B. Voss , D. Vranic , J. Wiechula , S. Winkler , J. Wikne , B. Windelband , C. Zhao

The NEXT-White detector, a high-pressure gaseous xenon time projection chamber, demonstrated the excellence of this technology for future neutrinoless double beta decay searches using photomultiplier tubes (PMTs) to measure energy and…

High Energy Physics - Experiment · Physics 2024-08-19 T. Contreras , B. Palmeiro , H. Almazán , A. Para , G. Martínez-Lema , R. Guenette , C. Adams , V. Álvarez , B. Aparicio , A. I. Aranburu , L. Arazi , I. J. Arnquist , F. Auria-Luna , S. Ayet , C. D. R. Azevedo , K. Bailey , F. Ballester , M. del Barrio-Torregrosa , A. Bayo , J. M. Benlloch-Rodríguez , F. I. G. M. Borges , A. Brodolin , N. Byrnes , S. Cárcel , A. Castillo , S. Cebrián , E. Church , L. Cid , C. A. N. Conde , F. P. Cossío , E. Dey , G. Díaz , T. Dickel , C. Echevarria , M. Elorza , J. Escada , R. Esteve , R. Felkai , L. M. P. Fernandes , P. Ferrario , A. L. Ferreira , F. W. Foss , Z. Freixa , J. García-Barrena , J. J. Gómez-Cadenas , R. González , J. W. R. Grocott , J. Hauptman , C. A. O. Henriques , J. A. Hernando Morata , P. Herrero-Gómez , V. Herrero , C. Hervés Carrete , Y. Ifergan , B. J. P. Jones , F. Kellerer , L. Larizgoitia , A. Larumbe , P. Lebrun , F. Lopez , N. López-March , R. Madigan , R. D. P. Mano , A. P. Marques , J. Martín-Albo , M. Martínez-Vara , R. L. Miller , K. Mistry , J. Molina-Canteras , F. Monrabal , C. M. B. Monteiro , F. J. Mora , K. E. Navarro , P. Novella , A. Nuñez , D. R. Nygren , E. Oblak , J. Palacio , I. Parmaksiz , A. Pazos , J. Pelegrin , M. Pérez Maneiro , M. Querol , A. B. Redwine , J. Renner , I. Rivilla , C. Rogero , L. Rogers , B. Romeo , C. Romo-Luque , F. P. Santos , J. M. F. dos Santos , M. Seemann , I. Shomroni , P. A. O. C. Silva , A. Simón , S. R. Soleti , M. Sorel , J. Soto-Oton , J. M. R. Teixeira , S. Teruel-Pardo , J. F. Toledo , C. Tonnelé , J. Torrent , A. Trettin , A. Usón , P. R. G. Valle , J. F. C. A. Veloso , J. Waiton , A. Yubero-Navarro

We report on the progress in the study of cascaded GEM and GEM/MHSP gas avalanche photomultipliers operating at atmospheric pressure, with CsI and bialkali photocathodes. They have single-photon sensitivity, ns time resolution and good…

Instrumentation and Detectors · Physics 2011-04-11 A. Breskin , D. Mormann , A. Lyashenko , R. Chechik , F. D. Amaro , J. M. Maia , J. F. C. A. Veloso , J. M. F. dos Santos

Dedicated R&D efforts are currently underway to couple a thin Cherenkov radiator to Silicon Photomultiplier (SiPM) arrays for precise charged particle Time-of-Flight (ToF) measurements. The prompt nature of Cherenkov radiation makes it an…

Instrumentation and Detectors · Physics 2026-01-22 M. N. Mazziotta , A. Di Mauro , M. Giliberti , A. Liguori , L. Lorusso , E. Nappi , N. Nicassio , G. Panzarini , R. Pillera , G. Volpe

Conventional silicon photomultipliers (SiPMs) are well established as light detectors with single-photon-detection capability and used throughout high energy physics, medical, and commercial applications. The possibility to produce single…

We present advances made in the Large Area Picosecond Photodetector (LAPPD), an 8" $\times$ 8" microchannel plate photomultiplier tube (MCP-PMT), since pilot production was initiated at Incom, Inc. in 2018. The Gen-I LAPPD utilizes a…

This publication focuses on the study of silicon photomultipliers (SiPMs) in view of a reconstruction of the incident photon flux in the regime of highly non-linear response. SiPMs are semiconductor based light detectors compiled of…

Instrumentation and Detectors · Physics 2020-10-29 T. Bretz , T. Hebbeker , J. Kemp

In this work, we present a novel compact particle identification (PID) detector concept based on Silicon Photomultipliers (SiPMs) optimized to perform combined Ring-Imaging Cherenkov (RICH) and Time-of-Flight (TOF) measurements using a…

Instrumentation and Detectors · Physics 2026-01-22 M. N. Mazziotta , L. Congedo , G. De Robertis , M. Giliberti , F. Licciulli , A. Liguori , L. Lorusso , N. Nicassio , G. Panzarini , R. Pillera

The experimental requirements in near future accelerators (e.g. High Luminosity-LHC) has stimulated intense interest in development of detectors with high precision timing capabilities. With this as a goal, a new detection concept called…

Future tonne-scale liquefied noble gas detectors depend on efficient light detection in the VUV range. In the past years Silicon Photomultipliers (SiPMs) have emerged as a valid alternative to standard photomultiplier tubes or large area…

Instrumentation and Detectors · Physics 2019-03-14 A. Jamil , T. Ziegler , P. Hufschmidt , G. Li , L. Lupin-Jimenez , T. Michel , I. Ostrovskiy , F. Retière , J. Schneider , M. Wagenpfeil , J. B. Albert , G. Anton , I. J. Arnquist , I. Badhrees , P. Barbeau , D. Beck , V. Belov , J. P. Brodsky , E. Brown , T. Brunner , A. Burenkov , G. F. Cao , L. Cao , W. R. Cen , C. Chambers , S. A. Charlebois , M. Chiu , B. Cleveland , M. Coon , A. Craycraft , W. Cree , M. Côté , J. Dalmasson , T. Daniels , S. J. Daugherty , J. Daughhetee , S. Delaquis , A. Der Mesrobian-Kabakian , R. DeVoe , T. Didberidze , J. Dilling , Y. Y. Ding , M. J. Dolinski , A. Dragone , J. Echevers , L. Fabris , D. Fairbank , W. Fairbank , J. Farine , S. Feyzbakhsh , R. Fontaine , D. Fudenberg , G. Gallina , G. Giacomini , R. Gornea , G. Gratta , E. V. Hansen , D. Harris , M. Hasan , M. Heffner , E. W. Hoppe , A. House , M. Hughes , J. Hößl , Y. Ito , A. Iverson , M. Jewell , X. S. Jiang , A. Karelin , L. J. Kaufman , T. Koffas , S. Kravitz , R. Krücken , A. Kuchenkov , K. S. Kumar , Y. Lan , D. S. Leonard , S. Li , Z. Li , C. Licciardi , Y. H. Lin , R. MacLellan , B. Mong , D. Moore , K. Murray , R. J. Newby , Z. Ning , O. Njoya , F. Nolet , K. Odgers , A. Odian , M. Oriunno , J. L. Orrell , C. T. Overman , G. S. Ortega , S. Parent , A. Piepke , A. Pocar , J. -F. Pratte , D. Qiu , V. Radeka , E. Raguzin , T. Rao , S. Rescia , A. Robinson , T. Rossignol , P. C. Rowson , N. Roy , R. Saldanha , S. Sangiorgio , S. Schmidt , A. Schubert , D. Sinclair , K. Skarpaas , A. K. Soma , G. St-Hilaire , V. Stekhanov , T. Stiegler , X. L. Sun , M. Tarka , J. Todd , T. Tolba , R. Tsang , T. Tsang , F. Vachon , V. Veeraraghavan , G. Visser , J. -L. Vuilleumier , Q. Wang , M. Weber , W. Wei , L. J. Wen , U. Wichoski , G. Wrede , S. X. Wu , W. H. Wu , Q. Xia , L. Yang , Y. -R. Yen , O. Zeldovich , X. Zhang , J. Zhao , Y. Zhou

The concept and subsequent experimental verification of the proportionality between pulse amplitude and detector transit time for microchannel plate detectors is presented. This discovery has led to considerable improvement in the overall…

Quantum Physics · Physics 2009-11-13 Victor D. Irby

In the Energy Frontier we suggest developing high rate (100 MHz) finely segmented forward calorimetry preradiators with time resolution <50 ps which will survive the first 1-2 Lint of incident high radiation doses, protecting forward…

Instrumentation and Detectors · Physics 2022-03-21 David R Winn , Yasar Onel

Advances in the technologies associated with position sensitive gaseous detectors especially featuring CsI as reflective photoconverters will be reviewed. These photodetectors represent the most effective solution for what concerns cost and…

Instrumentation and Detectors · Physics 2010-08-10 P. Martinengo , E. Nappi , V. Peskov

Particle beam microscopy (PBM) performs nanoscale imaging by pixelwise capture of scalar values representing noisy measurements of the response from secondary electrons (SEs) integrated over a dwell time. Extended to metrology, goals…

Data Analysis, Statistics and Probability · Physics 2023-08-15 Akshay Agarwal , Minxu Peng , Vivek K. Goyal

Silicon photomultipliers (SiPMs) have a few advantages over conventional photomultiplier tubes (PMTs) used in imaging atmospheric Cherenkov telescopes. The first notable characteristic is their higher photon detection efficiency (PDE) of up…

Instrumentation and Methods for Astrophysics · Physics 2023-09-19 Akira Okumura , Junya Haga , Chiaki Inoue , Keiji Nishimoto , Kazuhiro Furuta , Hiroyasu Tajima

The ALICE Collaboration is proposing a completely new apparatus, ALICE~3, for the LHC Runs~5 and beyond. In this context, a key subsystem for high-energy charged particle identification will be a proximity-focusing ring-imaging Cherenkov…