Related papers: Development and characterization of the efficient …
Operation of semiconductor scintillators requires optically-tight integration of the photoreceiver system on the surface of the scintillator slab. We have implemented an efficient and fast quaternary InGaAsP pin photodiode, epitaxially…
In recent years, scientific CMOS (sCMOS) sensors have found increasing applications to X-ray detection, including X-ray astronomical observations. In order to examine the performance of sCMOS sensors, we have developed X-ray cameras based…
We developed an FPGA-based high-speed readout system for a complementary metal-oxide-semiconductor (CMOS) image sensor to observe soft X-ray transients in future satellite missions, such as HiZ-GUNDAM. Our previous research revealed that…
Gamma-ray polarization offers a unique probes into the geometry of the gamma-ray emission process in celestial objects. The Soft Gamma-ray Detector (SGD) onboard the X-ray observatory Hitomi is a Si/CdTe Compton camera and is expected to be…
Charge Coupled Devices (CCDs) have been successfully used in several low energy X-ray astronomical satellite over the past two decades. Their high energy resolution and high spatial resolution make them an perfect tool for low energy…
This paper discusses the latest progress in the development of GRAPE (Gamma-Ray Polarimeter Experiment), a hard X-ray Compton Polarimeter. The purpose of GRAPE is to measure the polarization of hard X-rays in the 50-300 keV energy range. We…
We demonstrate an experimental method for direct 2D and 3D imaging of magnetic radio-frequency (rf) field distribution in metal-dielectric structures based on traveling wave (TW) magnetic resonance imaging (MRI) at ultra-high field (> 7T).…
In recent years, the performance of Scientifc Complementary Metal Oxide Semiconductor (sCMOS) sensors has been improved signifcantly. Compared with CCD sensors, sCMOS sensors have various advantages, making them potentially better devices…
Based on grating diffraction principle, optical fiber transmission principle and optical interference principle, a multi-functional portable optical measuring instrument is constructed in this paper. The optical measurement visualization…
We propose an imaging system and methodology for mapping soft-tissue samples in three dimensions, with micron-scale and isotropic spatial resolution, with low-concentrations as well as in the absence of heavy metal staining. We used hard…
We have developed an improved method of time-resolved x-ray reflectivity (XRR) using monochromatic synchrotron radiation. Our method utilizes a polycapillary x-ray optic to create a range of incident angles and an area detector to collect…
Fabrication of X-ray gratings has surged in the last two decades thanks to their vast employment in X-ray Phase Contrast Imaging, an imaging technique able to boost X-ray sensitivity to detect otherwise invisible details. These high aspect…
The results obtained in laboratory tests, using scintillator bars read by silicon photomultipliers are reported. The present approach is the first step for designing a precision tracking system to be placed inside a free magnetized volume…
X-ray spectral fitting in high-energy astrophysics can be reliably accelerated using Machine Learning. In particular, Simulation-based Inference (SBI) produces accurate posterior distributions in the Gaussian and Poisson regime for…
Nowadays, commonly used Resistive Plate Chambers (RPCs) have counting rate capabilities of ~10E4Hz/cm2 and position resolutions of ~1cm. We have developed small prototypes of RPCs (5x5 and 10x10cm2) having rate capabilities of up to…
A beam imaging detector was developed by coupling a multi-strip anode with delay line readout to an E$\times$B microchannel plate (MCP) detector. This detector is capable of measuring the incident position of the beam particles in…
An X-ray Interferometer (XRI) has recently been proposed as a theme for ESA's Voyage 2050 planning cycle, with the eventual goal to observe the X-ray sky with an unprecedented angular resolution better than 1 micro arcsec (5 prad) [1]. A…
A rotational modulator (RM) gamma-ray imager is capable of obtaining significantly better angular resolution than the fundamental geometric resolution defined by the ratio of detector diameter to mask-detector separation. An RM imager…
Results from the simulations of a Compton gamma camera based on compact configuration of detectors consisting in two detection modules, each of them having two stages of high-resolution position- and energy-sensitive radiation detectors…
Organ-specific, targeted Field-of-View (FoV) Positron Emission Tomography (PET)/Magnetic Resonance Imaging (MRI) inserts are viable solutions for a number of imaging tasks where whole-body PET/MRI systems lack the necessary sensitivity and…