English
Related papers

Related papers: Conceptual Design of Highly-Constrained Splitters …

200 papers

This white paper summarizes the scientific opportunities for utilization of the upgraded 12 GeV Continuous Electron Beam Accelerator Facility (CEBAF) and associated experimental equipment at Jefferson Lab. It is based on the 52 proposals…

The project to upgrade the CEBAF accelerator at Jefferson Lab to 12 GeV is presented. Most of the research program supporting that upgrade, will require a highly polarized beam, as will be illustrated by a few selected examples. To carry…

Nuclear Experiment · Physics 2014-11-18 Kees de Jager

Construction of the 12 GeV upgrade to the Continuous Electron Beam Accelerator Facility (CEBAF) at the Thomas Jefferson National Accelerator Facility is presently underway. This upgrade includes doubling the energy of the electron beam to…

Instrumentation and Detectors · Physics 2011-09-30 R. D. McKeown

The Continuous Electron Beam Accelerator Facility (CEBAF) and associated experimental equipment at Jefferson Lab comprise a unique facility for experimental nuclear physics. This facility is presently being upgraded, which will enable a new…

Nuclear Experiment · Physics 2015-06-23 R. D. McKeown

This review paper describes the energy-upgraded CEBAF accelerator. This superconducting linac has achieved 12 GeV beam energy by adding 11 new high-performance cryomodules containing eighty-eight superconducting cavities that have operated…

Accelerator Physics · Physics 2024-09-02 P. A. Adderley , S. Ahmed , T. Allison , R. Bachimanchi , K. Baggett , M. BastaniNejad , B. Bevins , M. Bevins , M. Bickley , R. M. Bodenstein , S. A. Bogacz , M. Bruker , A. Burrill , L. Cardman , J. Creel , Y. -C. Chao , G. Cheng , G. Ciovati , S. Chattopadhyay , J. Clark , W. A. Clemens , G. Croke , E. Daly , G. K. Davis , J. Delayen , S. U. De Silva , R. Dickson , M. Diaz , M. Drury , L. Doolittle , D. Douglas , E. Feldl , J. Fischer , A. Freyberger , V. Ganni , R. L. Geng , C. Ginsburg , J. Gomez , J. Grames , J. Gubeli , J. Guo , F. Hannon , J. Hansknecht , L. Harwood , J. Henry , C. Hernandez-Garcia , S. Higgins , D. Higinbotham , A. S. Hofler , T. Hiatt , J. Hogan , C. Hovater , A. Hutton , C. Jones , K. Jordan , M. Joyce , R. Kazimi , M. Keesee , M. J. Kelley , C. Keppel , A. Kimber , L. King , P. Kjeldsen , P. Kneisel , J. Koval , G. A. Krafft , G. Lahti , T. Larrieu , R. Lauze , C. Leemann , R. Legg , R. Li , F. Lin , D. Machie , J. Mammosser , K. Macha , K. Mahoney , F. Marhauser , B. Mastracci , J. Matalevich , J. McCarter , M. McCaughan , L. Merminga , R. Michaud , V. Morozov , C. Mounts , J. Musson , R. Nelson , W. Oren , R. B. Overton , G. Palacios-Serrano , H. -K. Park , L. Phillips , S. Philip , F. Pilat , T. Plawski , M. Poelker , P. Powers , T. Powers , J. Preble , T. Reilly , R. Rimmer , C. Reece , H. Robertson , Y. Roblin , C. Rode , T. Satogata , D. J. Seidman , A. Seryi , A. Shabalina , I. Shin , R. Slominski , C. Slominski , M. Spata , D. Spell , J. Spradlin , M. Stirbet , M. L. Stutzman , S. Suhring , K. Surles-Law , R. Suleiman , C. Tennant , H. Tian , D. Turner , M. Tiefenback , O. Trofimova , A. -M. Valente , H. Wang , Y. Wang , K. White , C. Whitlatch , T. Whitlatch , M. Wiseman , M. J. Wissman , G. Wu , S. Yang , B. Yunn , S. Zhang , Y. Zhang

The Continuous Electron Beam Accelerator Facility (CEBAF) and associated experimental equipment at Jefferson Lab comprise a unique facility for experimental nuclear physics. This facility is presently being upgraded, which will enable a new…

Accelerator Physics · Physics 2013-03-27 R. D. McKeown

The upgrade of the CEBAF Accelerator at Jefferson Lab to 12 GeV will deliver high luminosity and high quality beams, which will open unique opportunities for studies of the quark and gluon structure of hadrons in the valence region. Such…

Nuclear Experiment · Physics 2010-02-25 Elton S. Smith

The Continuous Electron Beam Accelerator Facility (CEBAF) at the Thomas Jefferson National Accelerator Facility provides CW electron beams with high intensity, remarkable stability, and a high degree of polarization. These capabilities…

High Energy Physics - Experiment · Physics 2015-05-30 R. D. McKeown

One of the major upcoming challenges in particle physics is achieving precise measurements of the Z, W, and H bosons, as well as the top quark. To meet these targets, the next e\textsuperscript{+}e\textsuperscript{-} collider complex,…

In this paper, a novel concept combining a fixed field alternating gradient accelerator with time-varying quadrupoles is presented which solves some of the major problems of conventional fixed field accelerators. This concept combines a…

Accelerator Physics · Physics 2019-05-15 Malek Haj Tahar , David J. Brenner , Gerhard Randers-Pehrson

Precise and accurate measurements of the beam energy delivered to the experimental halls at the Thomas Jefferson Accelerator Facility (Jefferson Lab) is required by many experiments for proper data analysis and physics event reconstruction.…

Accelerator Physics · Physics 2021-10-15 S. N. Santiesteban , L. Tracy , D. Flay , D. W. Higinbotham , D. Marchand , P. Vernin , A Saha

We summarize the ongoing scientific program of the 12 GeV Continuous Electron Beam Accelerator Facility (CEBAF) and give an outlook into future scientific opportunities. The program addresses important topics in nuclear, hadronic, and…

Laser plasma accelerators have the potential to reduce the size of future linacs for high energy physics by more than an order of magnitude, due to their high gradient. Research is in progress at current facilities, including the BELLA…

Accelerator Physics · Physics 2013-10-01 C. G. R. Geddes , J. -L. Vay , C. B. Schroeder , E. Esarey , W. P. Leemans

Crystal electromagnetic calorimeters (ECALs) are essential for high-precision measurements of electrons and photons in particle physics experiments. However, the conventional design, in which long crystal bars point radially toward the…

Instrumentation and Detectors · Physics 2026-02-26 Weizheng Song , Yang Zhang , Shengsen Sun , Fangyi Guo , Yuanzhan Wang , Linghui Wu , Jie Guo , Shaojing Hou , Yong Liu , Quan Ji , Jinfan Chang , Yifang Wang

As compared to electron storage rings, one advantage of recirculating linear accelerators is that the beam properties at target are no longer dominated by the equilibrium between quantum radiative diffusion and radiation damping because new…

Accelerator Physics · Physics 2014-11-18 G. A. Krafft , J. -C. Denard , R. W. Dickson , R. Kazimi , V. A. Lebedev , M. G. Tiefenback

The CEBAF recirculating linear accelerator uses 26 septa: 8 thin, 17 thick and one Lambertson. We report here on detailed FEM models of one thick current-sheet septum, the Lambertson, and a new thick-septum concept which contains features…

Accelerator Physics · Physics 2018-12-05 J. Benesch

A technical note is given regarding our previous laboratory plasma-astrophysical studies [C.-S. Jao et al., High Energy Density Physics 32, 31-43 (2019) and Y. Chen et al., Nucl. Instrum. Methods Phys. Res., Sect. A 903, 119 (2018)]. In…

Instrumentation and Detectors · Physics 2019-11-04 Ye Chen , Chun-Sung Jao

Plasma wakefield acceleration (PWFA) holds much promise for advancing the energy frontier because it can potentially provide a 1000-fold or more increase in acceleration gradient with excellent power efficiency in respect with standard…

This work describes first commissioning results from the Cornell Brookhaven Energy Recovery Test Accelerator Fractional Arc Test. These include the recommissioning of the Cornell photo-injector, the first full energy operation of the main…

The Elastic Analysis Facility (EAF) hosted at Fermi National Accelerator Laboratory (Fermilab) is a platform being developed with the goal of providing a fast and efficient facility for physics analysis. As high-energy physics moves towards…

Data Analysis, Statistics and Probability · Physics 2025-06-11 Elise Chavez , Maria Acosta-Flechas , Christophe Bonnaud , Burt Holzman , Tulika Bose
‹ Prev 1 2 3 10 Next ›