English
Related papers

Related papers: Simulation Study for Particle Identification with …

200 papers

This paper presents recent progress in the development and mass production of large-area hydrophobic silica aerogels for use as radiators in the aerogel-based ring-imaging Cherenkov (A-RICH) counter, which will be installed in the forward…

The DIRC is a new type of Cherenkov imaging device that will be used for the first time in the BABAR detector at the asymmetric B-factory, PEP-II. It is based on total internal reflection and uses long, rectangular bars made from synthetic…

High Energy Physics - Experiment · Physics 2015-06-25 DIRC Collaboration

The Electron-Ion Collider (EIC) will be the next frontier project of nuclear physics in the United States. It is planned to be built in the Brookhaven National Laboratory (BNL) in close collaboration with Jefferson Lab. One of the key…

Instrumentation and Detectors · Physics 2022-02-15 Greg Kalicy

The very high momentum particle identification detector proposed for the ALICE upgrade is a focusing RICH using a C4F10 gaseous radiator. For the detection of Cherenkov photons, one of the options currently under investigation is to use a…

Instrumentation and Detectors · Physics 2010-09-14 A. Breskin , V. Peskov , A. Di Mauro , P. Martineng , D. Mayani Paras , L. Molnar , E. Nappi , G. Paic , J. van Hoorne

The DIRC technology (Detection of Internally Reflected Cherenkov light) offers an excellent possibility to minimize the form factor of Cherenkov detectors in hermetic high energy detectors. The PANDA experiment at FAIR in Germany will…

We describe the particle identification capability of the CLEO RICH system. This system consists of a 1 cm thick LiF radiator coupled to a photon detector that uses wire proportional chambers filled with a mixture of CH$_4$ and TEA. We…

Instrumentation and Detectors · Physics 2019-08-14 R. Sia

The ePIC detector is being designed as a general-purpose detector to deliver the full physics program of the Electron-Ion Collider (EIC) in BNL USA. Particle Identification (PID) plays a crucial role in the EIC physics program. Over a wide…

Instrumentation and Detectors · Physics 2025-01-07 Chandradoy Chatterjee

The DIRC is a new type of Cherenkov detector that is successfully operating as the hadronic particle identification system for the BABAR experiment at SLAC. The fused silica bars that serve as the DIRC's Cherenkov radiators must transmit…

High Energy Physics - Experiment · Physics 2015-06-25 M. Convery , B. Ratcliff , X. Sarazin , J. Schwiening , J. Va'vra

The CLEO-III Detector upgrade for charged particle identification is discussed. The RICH design uses solid LiF crystal radiators coupled with multi-wire chamber photon detectors, using TEA as the photosensor, and low-noise Viking readout…

The GlueX experiment at Jefferson Laboratory aims to perform quantitative tests of non-perturbative QCD by studying the spectrum of light-quark mesons and baryons. A Detector of Internally Reflected Cherenkov light (DIRC) was installed to…

Cherenkov imaging detectors will continue to play a central role for particle identification in future particle and nuclear physics experiments. Growing demands on momentum coverage, timing precision, radiation tolerance, and sustainability…

Instrumentation and Detectors · Physics 2026-03-27 Chandradoy Chatterjee

The Aerogel Ring Imaging Cherenkov (ARICH) counter serves as a particle identification device in the forward end-cap region of the Belle II spectrometer. It is capable of identifying pions and kaons with momenta up to $4 \, {\rm GeV}/c$ by…

We describe the two major components of CLEO III: the Silicon Vertex Detector and the Ring Imaging Cherenkov Detector (RICH). The Silicon Vertex Detector is a four layer barrel-style device which spans the radial distance from 2.5 cm to…

High Energy Physics - Experiment · Physics 2007-05-23 Marina Artuso

Particle identification at the Belle II experiment will be provided by two ring imaging Cherenkov devices, the time of propagation counters in the central region and the proximity focusing RICH with aerogel radiator in the forward end-cap…

Instrumentation and Detectors · Physics 2017-06-28 S. Sandilya

We report on test results of a novel ring imaging Cherenkov (RICH) detection system consisting of a 3 meter long gaseous C4F8O radiator, a focusing mirror, and a photon detector array based on Hamamatsu multi-anode photomultiplier tubes.…

The use of a nonhomogeneous aerogel radiator, i.e. one consisting of layers with different refractive indices, has been shown to improve the resolution of the Cherenkov angle measured with a proximity focusing RICH detector. In order to…

Instrumentation and Detectors · Physics 2008-11-26 Peter Krizan , Samo Korpar , Toru Iijima

The DIRC, a novel type of Cherenkov ring imaging device, is the primary hadronic particle identification system for the BaBar detector at the asymmetric B-factory Pep-II at SLAC. It is based on total internal reflection and uses long,…

High Energy Physics - Experiment · Physics 2007-05-23 T. Hadig

The Electron-ion collider in China (EicC) is a proposed future electron-ion collider designed to achieve a high luminosity, with a center-of-mass energy ranging from 15 to 20 GeV. Excellent particle identification (PID) with extensive…

Instrumentation and Detectors · Physics 2026-05-25 Xin Li , Yuxiang Zhao , Yutie Liang , Xu Sun

Beam diagnostics are crucial for smooth accelerator operations. Many techniques rely on instrumentation in which the beam properties are significantly affected by the measurement. Novel approaches aim to use Cherenkov Diffraction Radiation…

We are constructing a Ring Imaging Cherenkov detector (RICH) for the CLEO III upgrade for precision charged hadron identification. The RICH uses plane and sawtooth LiF crystals as radiators, MWPCs as photon detectors with TEA as the…