Related papers: High-intensity LINACS: Dynamics, Instabilities and…
Radio-frequency linear accelerators are used as injectors for synchrotrons and as stand-alone accelerators for the production of intense particle beams, thanks to their ability to accelerate high beam currents at high repetition rates. This…
In this paper, we give some guidelines for the design of linear accelerators, with special emphasis on their use in a hadron therapy facility. We concentrate on two accelerator layouts, based on linacs. The conventional one based on a linac…
This paper gives a very brief summary of longitudinal beam dynamics for both linear and circular accelerators. After discussing synchronism conditions in linacs, it focuses on particle motion in synchrotrons. It summarizes the equations of…
The conception of High Power Linac developed in Russian accelerator centres is based on the use of independently phased SC resonators with quadrupole lenses between them. The type and parameters of the resonators as well as focusing…
The continue wave (CW) high current proton linac has wide applications as the front end of the high power proton machines. The low energy part is the most difficult one and there is no widely accepted solution yet. Both normal conducting…
An overview of various typical instruments used for high-intensity hadron beams is given. In addition, a few important diagnostic methods are discussed which are quite special for these kinds of beams.
The CLIC linear collider aims at accelerating multiple bunches of electrons and positrons and colliding them at a centre of mass energy of 3 TeV. These bunches will be accelerated through X-band linacs, operating at an accelerating…
Spallation source dedicated for neutron scattering experiments, as well as multi-purpose facilities serving several applications call for pulsed mode operation of a high intensity proton linac. There is general agreement on the…
In this paper, we give an overview of the different types of linac accelerators, with special emphasis on their use for a hadron-therapy facility.
Beam loss is a critical issue in high-intensity accelerators, and much effort is expended during both the design and operation phases to minimize the loss and to keep it to manageable levels. As new accelerators become ever more powerful,…
High-frequency hadron-therapy linacs have been studied for the last 20 years and are now being built for dedicated proton-therapy centres. The main reason for using high-frequency linacs, in spite of the small apertures and low-duty cycle,…
This lecture is an introduction to the design of a spallation neutron source and other high intensity proton sources. It discusses two different approaches: linac-based and synchrotron-based. The requirements and design concepts of each…
The main features of radio-frequency linear accelerators are introduced, reviewing the different types of accelerating structures and presenting the main characteristics aspects of linac beam dynamics.
We review known and discuss new signatures of high-intensity Compton scattering assuming a scenario where a high-power laser is brought into collision with an electron beam. At high intensities one expects to see a substantial red-shift of…
The HE-LHC study investigates the possibilities for upgrading the beam energy of the Large Hadron Collider CERN from 7 TeV to 16.5 TeV. This paper presents a preliminary investigation of intensity issues and machine protection for the…
The implications of long-range wakefields on the beam quality are investigated through a detailed beam dynamics study. Injection offsets are considered and the resulting emittance dilution recorded, including systematic sources of error.…
The CLIC study of a high-energy (0.5 - 5 TeV), high-luminosity (1034 - 1035 cm-2 sec-1) e+e- linear collider is presented. Beam acceleration using high frequency (30 GHz) normal-conducting structures operating at high accelerating fields…
One of the most severe limitations in high-intensity particle colliders is the beam-beam interaction, i.e. the perturbation of the beams as they cross the opposing beams. This introduction to beam-beam effects concentrates on a description…
The Drive Beam Linac of the Compact Linear Collider (CLIC) has to accelerate an electron beam with 4.2 A up to 2.4 GeV in almost fully-loaded structures. The pulse contains about 70000 bunches, one in every second rf bucket, and has a…
We report the results of observations of H- beam instabilities at the Fermilab Linac. By intentionally creating "high" background pressure with different gases in the 750 keV transport line we observed coherent transverse beam oscillations.…