Related papers: Low performing pixel correction in computed tomogr…
Differential phase-contrast computed tomography (DPC-CT) is a powerful analysis tool for soft-tissue and low-atomic-number samples. Limited by the implementation conditions, DPC-CT with incomplete projections happens quite often.…
In recent years, the field of image inpainting has developed rapidly, learning based approaches show impressive results in the task of filling missing parts in an image. But most deep methods are strongly tied to the resolution of the…
Magnetic resonance imaging (MRI) motion artifacts can seriously affect clinical diagnostics, making it challenging to interpret images accurately. Existing methods for eliminating motion artifacts struggle to retain fine structural details…
For the task of metal artifact reduction (MAR), although deep learning (DL)-based methods have achieved promising performances, most of them suffer from two problems: 1) the CT imaging geometry constraint is not fully embedded into the…
Self-similarity learning has been recognized as a promising method for single image super-resolution (SR) to produce high-resolution (HR) image in recent years. The performance of learning based SR reconstruction, however, highly depends on…
The quality of the reconstructed photoacoustic image largely depends on the amount of photoacoustic (PA) boundary data available, which in turn is proportional to the number of detectors employed. In case of limited data (owing to less…
Metal objects pose a significant challenge in cone-beam computed tomography, as their strong and energy-dependent X-ray attenuation leads to inconsistent projections and severe streaking and shading artifacts in reconstructed images. These…
In this paper, we propose a novel deep convolutional neural network (CNN)-based algorithm for solving ill-posed inverse problems. Regularized iterative algorithms have emerged as the standard approach to ill-posed inverse problems in the…
Endoscopy is a routine imaging technique used for both diagnosis and minimally invasive surgical treatment. Artifacts such as motion blur, bubbles, specular reflections, floating objects and pixel saturation impede the visual interpretation…
Video compression artifact reduction aims to recover high-quality videos from low-quality compressed videos. Most existing approaches use a single neighboring frame or a pair of neighboring frames (preceding and/or following the target…
Computed tomography (CT) images containing metallic objects commonly show severe streaking and shadow artifacts. Metal artifacts are caused by nonlinear beam-hardening effects combined with other factors such as scatter and Poisson noise.…
We introduce a new, integrated approach to uncalibrated photometric stereo. We perform 3D reconstruction of Lambertian objects using multiple images produced by unknown, directional light sources. We show how to formulate a single…
Generating crisp, i.e., one-pixel-wide, edge maps remains one of the fundamental challenges in edge detection, affecting both traditional and learning-based methods. To obtain crisp edges, most existing approaches rely on two hand-crafted…
This paper deals with tomographic image reconstruction under the situation where some of projection data bins are contaminated with abnormal data. Such situations occur in various instances of tomography. We propose a new reconstruction…
Rigid-motion artifacts, such as cortical bone streaking and trabecular smearing, hinder in vivo assessment of bone microstructures in high-resolution peripheral quantitative computed tomography (HR-pQCT). Despite various motion grading…
A patch-based non-local restoration and reconstruction method for preprocessing degraded document images is introduced. The method collects relative data from the whole input image, while the image data are first represented by a…
We consider a Canonical Polyadic (CP) decomposition approach to low-rank tensor completion (LRTC) by incorporating external pairwise similarity relations through graph Laplacian regularization on the CP factor matrices. The usage of graph…
With the growing technology of photon-counting detectors (PCD), spectral CT is a widely concerned topic which has the potential of material differentiation. However, due to some non-ideal factors such as cross talk and pulse pile-up of the…
Long axial field-of-view PET scanners offer increased field-of-view and sensitivity compared to traditional PET scanners. However, a significant cost is associated with the densely packed photodetectors required for the extended-coverage…
Bias field, which is caused by imperfect MR devices or imaged objects, introduces intensity inhomogeneity into MR images and degrades the performance of MR image analysis methods. Many retrospective algorithms were developed to facilitate…