English
Related papers

Related papers: A SiPM-Based RICH Detector with Timing Capabilitie…

200 papers

The necessity to use Photo Multipliers (PM) as light detector limited in the past the use of crystals in radiation handled device preferring the Geiger approach. The Silicon Photomultipliers (SiPMs) are very small and cheap, solid photon…

Instrumentation and Detectors · Physics 2015-06-08 Valerio Bocci , Giacomo Chiodi , Francesco Iacoangeli , Massimo Nuccetelli , Luigi Recchia

Particle identification at high rates is an important challenge for many current and future high-energy physics experiments. The upgrade of the COMPASS RICH-1 detector requires a new technique for Cherenkov photon detection at count rates…

Instrumentation and Detectors · Physics 2019-08-15 F. Nerling

We present the final results from a novel Cherenkov imaging detector called the Focusing DIRC (FDIRC). This detector was designed as a full-scale prototype of the particle identification system for the SuperB experiment [1], and comprises…

Instrumentation and Detectors · Physics 2015-12-09 B. Dey , M. Borsato , N. Arnaud , D. W. G. S. Leith , K. Nishimura , D. A. Roberts , B. N. Ratcliff , G. Varner , J. Va'vra

Plastic scintillation detectors represent an efficient, cost-effective, customizable solution for assessment of gamma radiation fields in the context of nuclear security, environmental radiation survey, radiological and nuclear incidents…

Instrumentation and Detectors · Physics 2021-12-08 Paolo Tancioni , Ulisse Gendotti

Modeling the timing performance of light-based radiation detectors accurately is essential for optimizing time-of-flight positron emission tomography (TOF-PET). We present an analytic framework that combines existing models to predict the…

Instrumentation and Detectors · Physics 2025-10-08 Nicolaus Kratochwil , Emilie Roncali , Gerard Arino-Estrada

Radiation damage to a Silicon Photomultiplier (SiPM), as it occurs during the lifetime of the planned CMS high-granularity calorimeter detector, increases the dark current and degrades the signal-to-noise separation for minimum-ionizing…

Instrumentation and Detectors · Physics 2026-05-29 Katjana Neumann , Massimiliano Antonello , Lukas Brinkmann , Erika Garutti , Jörn Schwandt

A novel modular high-resolution charged-particle tracking detector design using $250\mu m$ diameter, round, scintillating fibers and SiPM arrays for readout is presented. The fiber modules consist of 8 layers of 128 fibers, mechanically sta…

Instrumentation and Detectors · Physics 2008-11-26 Henning Gast , Thomas Kirn , Gregorio Roper Yearwood , Stefan Schael

Gamma-ray observations in the very-high-energy domain (E > 30 GeV) can exploit the imaging of few-nanosecond Cherenkov flashes from atmospheric particle showers. Photomultipliers have been used as the primary photosensors to detect…

Instrumentation and Methods for Astrophysics · Physics 2019-08-14 Jonathan Biteau , David Chinn , Dennis Dang , Kevin Doyle , Caitlin A. Johnson , David A. Williams

A prototype of a position sensitive photo-detector with 5.6 x 5.6 cm2 detection area readout with 64 Hamamatsu MPPCs (S10931-100P) with 3 x 3 mm2 active area each has been built and tested. The photo-sensors are arranged in a 8 x 8 array…

Instrumentation and Detectors · Physics 2015-06-03 L. Gruber , G. S. M. Ahmed , S. E. Brunner , P. Bühler , J. Marton , K. Suzuki

Cherenkov imaging detectors will continue to play a central role for particle identification in future particle and nuclear physics experiments. Growing demands on momentum coverage, timing precision, radiation tolerance, and sustainability…

Instrumentation and Detectors · Physics 2026-03-27 Chandradoy Chatterjee

Silicon Photomultipliers (SiPMs) are considered as a solid-state sensor alternative to photomultiplier tubes in experiments using liquid xenon (LXe) as a radiation detection medium. The main requirements are single-photon detection of the…

Instrumentation and Detectors · Physics 2018-11-14 Laura Baudis , Michelle Galloway , Alexander Kish , Chris Marentini , Julien Wulf

With the emergence of advanced Silicon (Si) sensor technologies such as LGADs, it is now possible to achieve exceptional time measurement precision below 50 ps. As a result, the implementation of time-of-flight (TOF) particle identification…

High Energy Physics - Experiment · Physics 2023-11-09 Bohdan Dudar , Ulrich Einhaus , Jenny List , Konrad Helms , Frank Gaede

So far the current ground-based Imaging Atmospheric Cherenkov Telescopes (IACTs) have energy thresholds in the best case in the range of ~30 to 50 GeV (H.E.S.S. II and MAGIC telescopes). Lowest energy gamma-ray showers produce low light…

The ePIC detector is being designed as a general-purpose detector to deliver the full physics program of the Electron-Ion Collider (EIC) in BNL USA. Particle Identification (PID) plays a crucial role in the EIC physics program. Over a wide…

Instrumentation and Detectors · Physics 2025-01-07 Chandradoy Chatterjee

The TORCH time-of-flight detector is designed to provide a 15 ps timing resolution for charged particles, resulting in $\pi$/$K$ particle identification up to 10 GeV/c momentum over a 10 m flight path. Cherenkov photons, produced in a…

This paper describes the characterization of crystal matrices and silicon photomultiplier arrays for a novel Positron Emission Tomography (PET) detector, namely the external plate of the EndoTOFPET-US system. The EndoTOFPET-US collaboration…

The DIRC is a Cherenkov imaging detector based on total internal reflection for the BaBar detector at PEP-II. The principles of the DIRC ring imaging Cherenkov technique are explained and its choice for the BaBar detector particle…

High Energy Physics - Experiment · Physics 2009-10-30 J. Schwiening

Imaging Cherenkov detectors form the backbone of particle identification (PID) at the future Electron Ion Collider (EIC). Currently all the designs for the first EIC detector proposal use a dual Ring Imaging CHerenkov (dRICH) detector in…

Instrumentation and Detectors · Physics 2022-04-20 C. Fanelli , A. Mahmood

We report on the design, operation, and performance of a novel proximity-focusing Ring Imaging Cherenkov (RICH) detector equipped with a multilayer focusing aerogel radiator, developed for the forward region of the Belle II spectrometer at…

A combination Time Projection Chamber-Cherenkov prototype detector has been developed as part of the Detector R&D Program for a future Electron Ion Collider. The prototype was tested at the Fermilab test beam facility to provide a proof of…

Instrumentation and Detectors · Physics 2019-09-04 B. Azmoun , K. Dehmelt , T. K. Hemmick , R. Majka , H. N. Nguyen , M. Phipps , M. L. Purschke , N. Ram , W. Roh , D. Shangase , N. Smirnov , C. Woody , A. Zhang