The LArIAT liquid argon time projection chamber, placed in a tertiary beam of charged particles at the Fermilab Test Beam Facility, has collected large samples of pions, muons, electrons, protons, and kaons in the momentum range 300-1400…

Instrumentation and Detectors · Physics 2020-06-17 LArIAT Collaboration , R. Acciarri , C. J. Adams , J. Asaadi , M. Backfish , W. Badgett , B. Baller , O. Benevides Rodrigues , F. d. M. Blaszczyk , R. Bouabid , C. Bromberg , R. Carey , R. Castillo Fernandez , F. Cavanna , J. I. Cevallos Aleman , A. Chatterjee , P. Dedin Neto , M. V. Dos Santos , S. Dytman , D. Edmunds , M. Elkins , C. O. Escobar , J. Esquivel , J. Evans , A. Falcone , A. Farbin , W. Flanagan , B. Fleming , W. Foreman , D. Garcia-Gamez , D. Gastler , T. Ghosh , R. A. Gomes , E. Gramellini , R. Gran , P. Guzowski , A. Habig , A. Hahn , P. Hamilton , C. Hill , J. Ho , A. Holin , J. Hugon , E. Iwai , D. Jensen , R. A. Johnson , H. Jostlein , H. Kawai , E. Kearns , E. Kemp , M. Kirby , T. Kobilarcik , M. Kordosky , P. Kryczynski , K. Lang , R. Linehan , S. Lockwitz , X. Luo , A. A. B. Machado , A. Marchionni , T. Maruyama , L. Mendes Santos , W. Metcalf , C. A. Moura , R. Nichol , I. Nutini , A. Olivier , O. Palamara , J. Paley , I. Parmaksiz , B. Passarelli Gelli , L. Paulucci , D. Phan , G. Pulliam , J. L. Raaf , B. Rebel , M. Reggiani Guzzo , M. Ross-Lonergan , D. Schmitz , D. Sessumes , S. Shahsavarani , D. Shooltz , E. Segreto , D. Smith , M. Soares Nunes , M. Soderberg , B. Soubasis , F. Spagliardi , J. M. St. John , M. Stancari , D. Stefan , M. Stephens , R. Sulej , A. Szelc , M. Tabata , D. Totani , M. Tzanov , G. Valdiviesso , D. Walker , H. Wenzel , Z. Williams , T. Yang , J. Yu , G. Zeller , S. Zhang , J. Zhu

ArDM-1t is the prototype for a next generation WIMP detector measuring both the scintillation light and the ionization charge from nuclear recoils in a 1-ton liquid argon target. The goal is to reach a minimum recoil energy of 30\,keVr to…

Liquid argon technology is widely used by many previous and current neutrino experiments, and it is also promising for future large-scale neutrino experiments. When detecting neutrinos using liquid argon, many hadrons are involved, which…

Nuclear Experiment · Physics 2024-02-27 Yinrui Liu

Liquid nitrogen is commonly used in cryogenic applications and is a promising medium for the direct immersion cooling of sensors used for nuclear and particle physics experiments. The scintillation properties of gaseous nitrogen are…

Instrumentation and Detectors · Physics 2025-10-28 L. Pagani , R. Saldanha , B. M. Loer , G. S. Ortega , R. A. Bunker , B. T. Foust

The study of primary and secondary scintillations in noble gases and liquids is of paramount importance to rare-event experiments using noble gas media. In the present work, the scintillation yield in gaseous and liquid Ar has for the first…

Instrumentation and Detectors · Physics 2015-03-18 A. Buzulutskov , A. Bondar , A. Grebenuk

We report on the preparation of and calibration measurements with a $^{83\mathrm{m}}$Kr source for the CENNS-10 liquid argon detector. $^{83\mathrm{m}}$Kr atoms generated in the decay of a $^{83}$Rb source were introduced into the detector…

To increase the light yield of a liquid Ar (LAr) detector, we optimized the evaporation technique of tetraphenyl butadiene (TPB) on the detector surface and tested the operability of a silicon photomultiplier (SiPM), namely, the multi-pixel…

Instrumentation and Detectors · Physics 2022-05-04 Kazutaka Aoyama , Masashi Tanaka , Masato Kimura , Kohei Yorita

Future giant liquid argon (LAr) time projection chambers (TPCs) require a purity of better than 0.1 parts per billion (ppb) to allow the ionised electrons to drift without significant capture by any electronegative impurities. We present a…

Instrumentation and Detectors · Physics 2015-05-28 K. Mavrokoridis , R. G. Calland , J. Coleman , P. K. Lightfoot , N. McCauley , K. J. McCormick , C. Touramanis

The Liquid Argon Time Projection Chamber offers an innovative technology for a new class of massive detectors for rare-event detection. It is a precise tracking device that allows three-dimensional spatial reconstruction with mm-scale…

Instrumentation and Detectors · Physics 2015-06-15 A. Rubbia

Silicon photomultiplier (SiPM), a new type of photosensor, is considered a substitute for traditional photomultiplier tube (PMT) in the next generation of dark matter and neutrino detectors, especially in noble gas detectors like liquid…

Instrumentation and Detectors · Physics 2023-05-31 T. A. Wang , C. Guo , X. H. Liang , L. Wang , M. Y. Guan , C. G. Yang , J. C. Liu , F. Y. Lin

This is a brief review of liquid scintillators, an important technology for detection of ionizing radiation. We will first review the basic mechanisms of light production in most organic liquid scintillators. For most practical detector…

Instrumentation and Detectors · Physics 2024-08-06 Milind Vaman Diwan

The Deep Underground Neutrino Experiment (DUNE) is a leading-edge experiment for long-baseline neutrino oscillation studies, neutrino astrophysics and nucleon decay searches. ProtoDUNE-Dual Phase (DP) is a 6x6x6 m$^3$ liquid argon…

Instrumentation and Detectors · Physics 2022-01-19 I. Gil-Botella

Next generation multi-ton scale noble liquid experiments have the unique opportunity to discover dark matter particles at the TeV scale, reaching the sensitivity of 10^-48 cm2 in the WIMP nucleon scattering cross-section. A prerequisite…

Instrumentation and Detectors · Physics 2016-01-07 S. Catalanotti , A. G. Cocco , G. Covone , M. D Incecco , G. Fiorillo , G. Korga , B. Rossi , S. Walker

We describe a very compact (0.9 m high, 0.4 m diameter, 40 kg) battery operable neutron scatter camera designed for field deployment. Unlike most other systems, the configuration of the sixteen liquid-scintillator detection cells are…

Instrumentation and Detectors · Physics 2016-10-14 John E. M. Goldsmith , Mark D. Gerling , James S. Brennan

First observation of liquid xenon scintillation due to alpha-particles and gamma-rays with a large area avalanche photodiode immersed in the liquid is reported. An energy resolution of 10% (FWHM) and a coincidence time resolution of less…

Instrumentation and Detectors · Physics 2015-06-26 V. N. Solovov , A. Hitachi , V. Chepel , M. I. Lopes , R. Ferreira Marques , A. J. P. L. Policarpo

This paper reports on laser-induced multiphoton ionization at 266 nm of liquid argon in a time projection chamber (LAr TPC) detector. The electron signal produced by the laser beam is a formidable tool for the calibration and monitoring of…

Instrumentation and Detectors · Physics 2010-12-21 I. Badhrees , A. Ereditato , I. Kreslo , M. Messina , U. Moser , B. Rossi , M. S. Weber , M. Zeller , C. Altucci , S. Amoruso , R. Bruzzese , R. Velotta

This paper reports the results of an experiment to directly measure the time-resolved scintillation signal from the passage of cosmic-ray muons through liquid argon. Scintillation light from these muons is of value to studies of…

Instrumentation and Detectors · Physics 2016-05-24 Denver Whittington , Stuart Mufson , Bruce Howard

We demonstrate, for the time, the operation of a bubble-assisted Liquid Hole Multiplier (LHM) in liquid argon. The LHM, sensitive to both radiation-induced ionization electrons and primary scintillation photons, consists of a perforated…

Instrumentation and Detectors · Physics 2020-01-29 Eran Erdal , Andrea Tesi , Amos Breskin , David Vartsky , Shikma Bressler

The detection of primary scintillation light in combination with the charge or secondary scintillation signals is an efficient technique to determine the events t=0 as well as particle / photon separation in large mass TPC detectors filled…

Instrumentation and Detectors · Physics 2009-11-07 L. Periale , V. Peskov , P. Carlson , T. Francke , P. Pavlopoulos , P. Picchi , F. Pietropaolo

We report on a new measurement of the energy resolution that can be attained in liquid xenon when recording only the scintillation light. Our setup is optimized to maximize light collection, and uses state-of-the-art, high-PDE,…