Related papers: Measuring high-precision luminosity at the CEPC
The International Linear Collider (ILC) is a proposed electron-positron collider with a center-of-mass energy of 500~GeV, and a peak luminosity of $2 \cdot 10^{34}~\mathrm{cm}^{-2}\mathrm{s}^{-1}$. The ILC will complement the Large Hadron…
The measurement of small-angle Bhabha scattering is used to determine the luminosity at the OPAL interaction point for the LEP I data recorded between 1993 and 1995. The measurement is based on the OPAL Silicon-Tungsten Luminometer which is…
In order to measure integrated luminosity with a required precision of $10^{-4}$ at the $Z^0$ pole, proposed CEPC $e^{+}e^{-}$ collider requires a luminometer, a specially designed calorimeter placed in the very forward region to identify…
LumiCal will be the luminosity calorimeter for the proposed International Large Detector of the International Linear Collider (ILC). The ILC physics program requires the integrated luminosity to be measured with a relative precision on the…
Two special calorimeters are foreseen for the instrumentation of the very forward region of an ILC or CLIC detector; a luminometer (LumiCal) designed to measure the rate of low angle Bhabha scattering events with a precision better than…
A pair of compact Silicon-Tungsten calorimeters was operated in the OPAL experiment at LEP to measure the integrated luminosity from detection of Bhabha electrons scattered at angles between 25 and 58 mrad from the beam line. In the eight…
Future electron-positron ($\ee$) colliders, operating as Higgs factories or Z factories, promise unprecedented precision electroweak measurements that are vital to testing the Standard Model (SM) and exploring physics beyond it. Here we…
For cross section measurements, an accurate knowledge of the integrated luminosity is required. The FCC-ee Z lineshape programme sets the ambitious precision goal of $10^{-4}$ on the \emph{absolute} luminosity measurement and one order of…
Elastic light-by-light scattering, $\gamma\gamma\to\gamma\gamma$, can be measured in electromagnetic interactions of lead (Pb) ions at the Large Hadron Collider (LHC) and Future Circular Collider (FCC), using the large (quasi)real photon…
The Circular Electron-Positron Collider (CEPC), a next-generation high-luminosity collider, employs a crab waist scheme to achieve ultrahigh $5 \times 10^{34} \, \text{cm}^{-2}\text{s}^{-1}$ luminosity at Higgs mode. Owing to the extremely…
The first part of the physics programme of the integrated FCC (Future Circular Colliders) proposal includes measurements of Standard Model processes in $e^+e^-$ collisions (FCC-ee) with an unprecedented precision. In particular, the…
Two special calorimeters are foreseen for the instrumentation of the very forward region of the ILC detector, a luminometer designed to measure the rate of low angle Bhabha scattering events with a precision better than 10-3 and a low polar…
Measurement of the integrated luminosity at the International Linear Collider (ILC) will be accomplished by counting the rate of small angle Bhabha scattering events. The physics requirements for ILC set the constraint on the relative…
Measurements of light-by-light scattering (LbL, $\gamma\gamma$ $\to$ $\gamma\gamma$) and the Breit-Wheeler process (BW, $\gamma\gamma$ $\to$ $\mathrm{e^+e^-}$) are reported in ultraperipheral PbPb collisions at a centre-of-mass energy per…
The very forward region is one of the most challenging regions to instrument at a future $e^+e^-$ collider. At CEPC, machine-detector interface includes, among others, a calorimeter dedicated for precision measurement of the integrated…
In this paper we describe a method of luminosity measurement at the future linear collider ILC that estimates and corrects for the impact of the dominant sources of systematic uncertainty originating from the beam-induced effects and the…
Two finely segmented and very compact calorimeters are foreseen for the instrumentation of the very forward region of the ILC and the CLIC detectors; a luminometer to measure the rate of low angle Bhabha scattering events with a precision…
Precision measurement of the integrated luminosity $\mathcal{L}$ at future Higgs factories, including ILC, is of crucial importance for the cross-section measurements, and in particular for the line-shape measurements at the Z-pole. Since…
Special calorimeters are needed to instrument the very forward region of an ILC detector. These devices will improve the hermeticity being important for new particle searches. A luminometer is foreseen to measure the rate of low angle…
We present a study of the measurement of the effective weak mixing angle parameter ($\sin^2\theta^{\ell}_\text{eff}$) at the Circular Electron Positron Collider (CEPC). As a fundamental physics parameter, $\sin^2\theta^{\ell}_\text{eff}$…