Related papers: Robust Lifetime Estimation from HPGe Radiation-Sen…
A study of signals originating near the lithium-diffused n+ contact of p-type point contact (PPC) high purity germanium detectors (HPGe) is presented. The transition region between the active germanium and the fully dead layer of the n+…
The v = 1 -> 0 radiative lifetime of NH (X triplet-Sigma-, v=1,N=0) is determined to be tau_rad,exp. = 37.0 +/- 0.5 stat +2.0 / -0.8 sys miliseconds, corresponding to a transition dipole moment of |mu_10| = 0.0540 + 0.0009 / -0.0018 Debye.…
Large, high-purity, germanium (HPGe) detectors are needed for neutrinoless double-beta decay and dark matter experiments. Currently, large (> 4 inches in diameter) HPGe crystals can be grown at the University of South Dakota (USD). We…
Radiation detectors constructed from large volume high purity Ge (HPGe) single crystals are widely used for gamma-ray spectroscopy. The detectors for this application can be simple in that they need only have two electrical contacts for…
High Purity Germanium (HPGe) detectors are powerful detectors for gamma-ray spectroscopy. The sensitivity to low-intensity gamma-ray peaks is often hindered by the presence of Compton continuum distributions, originated by gamma-rays…
A new type of radiation detector, a p-type modified electrode germanium diode, is presented. The prototype displays, for the first time, a combination of features (mass, energy threshold and background expectation) required for a…
The study of neutrinoless double beta decay has attracted much attention as it can provide valuable information about the mass and the nature of the neutrino. The double beta decay (DBD) itself is also of interest in nuclear physics. While…
A gamma counting station based on high-purity germanium (HPGe) detector was set up for the material screening of the PandaX dark matter experiments in the China Jinping Underground Laboratory. Low background gamma rate of 2.6 counts/min…
This paper describes the energy scale procedures and germanium detectors performance in the LEGEND-200 experiment, a critical component for the first unblinding in the search for neutrinoless double beta decay. We detail the digital signal…
Neutrinoless double-beta decay ($0\nu\beta\beta$) is a rare nuclear process that, if observed, will provide insight into the nature of neutrinos and help explain the matter-antimatter asymmetry in the universe. The Large Enriched Germanium…
Detection systems rely more and more on on-line or off-line comparison of detected signals with basis signals in order to determine the characteristics of the impinging particles. Unfortunately, these comparisons are very sensitive to the…
The aim of this study is to estimate the intrinsic efficiency and energy resolution of different types of solid-state gamma-ray detectors in order to generate a precise dual-energy x-ray beam from the conventional x-ray tube using external…
The DArk Matter Particle Explorer (DAMPE) is well suitable for searching for monochromatic and sharp $\gamma$-ray structures in the GeV$-$TeV range thanks to its unprecedented high energy resolution. In this work, we search for $\gamma$-ray…
In this paper, we present the design and preliminary performance evaluation of a new heavy-ion detector for direct measurements of heavy {\Lambda} hypernuclei lifetime. The detector employs the previously developed 10 picosecond resolution…
Following work done in the energy region above 100 keV, the high-precision calibration of a co-axial high-purity germanium detector has been continued in the energy region below 100 keV. Previous measurements or Monte-Carlo simulations have…
The half-life of $^{6}$He has been measured using a low energy radioactive beam implanted in a YAP scintillator and recording decay events in a 4$\pi$ geometry. Events were time-stamped with a digital data acquisition system enabling a…
A new, more precise measurement of the $\Lambda$ hyperon lifetime is performed using a large data sample of Pb$-$Pb collisions at $\sqrt{s_{\rm NN}} = 5.02$ TeV with ALICE. The $\Lambda$ and $\overline{\Lambda}$ hyperons are reconstructed…
Starting from June 2011, the activity of a 137Cs source has been measured by means of a HPGe detector installed deep underground in the Gran Sasso Laboratory. In total about 5100 energy spectra, one hour measuring time each, have been…
The Gamma-Ray Infrastructure For Fundamental Investigations of Nuclei, GRIFFIN, is a new experimental facility for radioactive decay studies at the TRIUMF-ISAC laboratory. The performance of the 16 high-purity germanium (HPGe) clover…
The full-energy-peak efficiency of HPGe detectors at $\gamma$-ray energies around 10 MeV is not easily accessible with experimental methods. Monte-Carlo simulations with Geant4 can provide these efficiencies. G4Horus is a ready-to-use…