English
Related papers

Related papers: Light-tight skipper-CCDs for X-ray detection in sp…

200 papers

The readout noise for Charge-Coupled Devices (CCDs) has been the main limitation when using these detectors for measuring small amplitude signals. A readout system for a new scientific, low noise CCD is presented in this paper. The Skipper…

Instrumentation and Methods for Astrophysics · Physics 2015-05-28 Guillermo Fernandez Moroni , Juan Estrada , Eduardo E. Paolini , Gustavo Cancelo , Stephen E. Holland , H. Thomas Diehl

A charge-coupled device (CCD) is a standard imager in optical region in which the image quality is limited by its pixel size. CCDs also function in X-ray region but with substantial differences in performance. An optical photon generates…

Astrophysics · Physics 2009-11-07 E. Miyata , M. Miki , H. Tsunemi , J. Hiraga , H. Kouno , K. Miyaguchi

The purpose of this project is to investigate the use of charge couple devices (CCDs) to detect electrons directly. This can be done in transmission electron microscopy (TEM) for electrons over 100 KeV, but for space plasma instruments,…

Instrumentation and Detectors · Physics 2015-10-28 S. R. Mirfayzi

X-ray Charge Coupled Devices (CCDs) have been the workhorse for soft X-ray astronomical instruments for the past quarter century. They provide broad energy response, extremely low electronic read noise, and good energy resolution in soft…

X-ray detectors made of crystalline silicon have several advantages including low dark currents, fast charge collection and high energy resolution. For high-energy x-rays, however, silicon suffers from its low atomic number, which might…

Instrumentation and Detectors · Physics 2021-01-26 Moa Yveborg , Cheng Xu , Erik Fredenberg , Mats Danielsson

We present the first direct-detection search for eV-to-GeV dark matter using a new ~2-gram high-resistivity Skipper-CCD from a dedicated fabrication batch that was optimized for dark-matter searches. Using 24 days of data acquired in the…

We propose to search for millicharged particles produced in high-intensity electron beam dumps using small ultralow-threshold sensors. As a concrete example, we consider a Skipper-CCD placed behind the beam dump in Hall A at Jefferson Lab.…

High Energy Physics - Phenomenology · Physics 2025-03-04 Rouven Essig , Peiran Li , Zhen Liu , Megan McDuffie , Ryan Plestid , Hailin Xu

We present new direct-detection constraints on eV-to-GeV dark matter interacting with electrons using a prototype detector of the Sub-Electron-Noise Skipper-CCD Experimental Instrument. The results are based on data taken in the MINOS…

The soft X-ray imager (SXI) on the SMILE mission uses two large 4510x4510 back illuminated CCD370s to detect X-rays in the 0.2-2 keV range. These devices take heritage from the optical imaging PLATO mission CCD270s and have been optimised…

Instrumentation and Detectors · Physics 2022-10-26 S. Parsons , D. Hall , T. Buggey , A. Holland , P. Verhoeve

We introduce a charge coupled device (CCD) camera based detection scheme in dynamic light scattering that provides information on the single-scattered auto-correlation function even for fairly turbid samples. It is based on the single…

Soft Condensed Matter · Physics 2009-11-11 Pavel Zakharov , Suresh Bhat , Peter Schurtenberger , Frank Scheffold

The Soft X-ray Imager (SXI) is an imaging spectrometer using charge-coupled devices (CCDs) aboard the Hitomi X-ray observatory. The SXI sensor has four CCDs with an imaging area size of $31~{\rm mm} \times 31~{\rm mm}$ arranged in a $2…

We present experimental results using a single-electron resolution Skipper-CCD running above ground level to demonstrate the potential of this technology for its use in reactor neutrino observations and other low-energy particle interaction…

We report on a new photon-counting detector possessing unprecedented spatial resolution, moderate spectral resolution and high background-rejection capability for 0.1-100 keV X-rays. It consists of an X-ray charge-coupled device (CCD) and…

Astrophysics · Physics 2009-11-10 E. Miyata , K. Tamura

The Dark matter Nanosatellite Equipped with Skipper Sensors (DarkNESS) deploys a recently developed skipper-CCD architecture with sub-electron readout noise in low Earth orbit (LEO) to investigate potential signatures of dark matter (DM).…

Existing Charge-Coupled Devices (CCDs) operate by detecting either the electrons or holes created in an ionization event. We propose a new type of imager, the Dual-Sided CCD, which collects and measures both charge carriers on opposite…

We lay the foundations for a new fast method to reconstruct the electron density in x-ray scanning applications using measurements in the dark field. This approach is applied to a type of machine configuration with fixed energy sensitive…

Numerical Analysis · Mathematics 2015-05-08 James Webber

Silicon's bandgap inherently restricts its photodetection to wavelengths below 1100 nm, necessitating the integration of costly III-V semiconductors for short-wave infrared applications. Hyperdoping silicon beyond the solid solubility limit…

We present the development of a Skipper Charge-Coupled Device (CCD) focal plane prototype for the SOAR Telescope Integral Field Spectrograph (SIFS). This mosaic focal plane consists of four 6k $\times$ 1k, 15 $\mu$m pixel Skipper CCDs…