Related papers: First Positronium Lifetime Imaging using $^{52}$Mn…
Surface Plasmon Resonance (SPR) is an important bio-sensing technique for real-time label-free detection. However, it is pivotal to optimize various parameters of the sensor configuration for efficient and highly sensitive sensing. To that…
We demonstrate the use of an optimized 5 core photonic lantern (PL) to simultaneously measure tip/tilt errors at the telescope focal plane, while also providing the input to an instrument. By replacing a single mode (SM) fiber with the PL…
The scattering of ortho-positronium (Ps) by hydrogen atoms has been investigated in a five-state coupled-channel model allowing for Ps(1s)H(2s,2p) and Ps(2s,2p)H(1s) excitations using a recently proposed electron-exchange model potential.…
The adapted DIRAC experiment at the CERN PS accelerator observed for the first time long-lived hydrogen-like $\pi^+\pi^-$ atoms, produced by protons hitting a beryllium target. A part of these atoms crossed the gap of 96~mm and got broken…
Time-Of-Flight (TOF) is a noble technique that is used in Positron Emission Tomography (PET) imaging worldwide. The scintillator based imaging system that is being used around the world for TOF-PET is very expensive. Multi-gap Resistive…
Photonic Lanterns (PLs) are tapered waveguides that gradually transition from a multi-mode fiber geometry to a bundle of single-mode fibers (SMFs). They can efficiently couple multi-mode telescope light into a multi-mode fiber entrance at…
Muon scattering tomography is a non-destructive technique used to image different materials by utilizing natural cosmic ray muons. Typically it requires position-sensitive detectors with a sub-millimeter resolution to effectively…
We characterize the practical receiver in a wide range of signal intensity for optical wireless communication, from discrete pulse regime to continuous waveform regime. We first propose a statistical non-linear model based on the…
The nucleus 54Zn has been observed for the first time in an experiment at the SISSI/LISE3 facility of GANIL in the quasi-fragmentation of a 58Ni beam at 74.5 MeV/nucleon in a natNi target. The fragments were analysed by means of the…
Scattering of positronium (Ps) by helium atom has been investigated in a three-Ps-state coupled-channel model including Ps(1s,2s,2p) states using a recently proposed time-reversal-symmetric regularized electron-exchange model potential.…
Ortho-positronium (o-Ps) formation and decay can replace the annihilation process, when positron interacts in liquid scintillator media. The delay induced by the positronium decay represents either a potential signature for anti-neutrino…
Plastic scintillator strips are considered as one of the promising solutions for the cost-effective construction of total-body positron emission tomography, (PET) system. The purpose of the performed measurements is to compare the…
We demonstrate an electro-optic wide-field method to enable fluorescence lifetime microscopy (FLIM) with high throughput and single-molecule sensitivity. Resonantly driven Pockels cells are used to efficiently gate images at 39 MHz,…
Photoluminesce (PL) spectroscopy offers excellent methods for mapping the PL decay on the nanosecond time scale. However, capturing maps of emission dynamics on the microsecond time scale can be highly time-consuming. We present a new…
Proton therapy is nowadays becoming a wide spread clinical practice in cancer therapy and sophisticated treatment planning systems are routinely used to exploit at best the ballistic properties of charged particles. The information on the…
The ``neutron lifetime puzzle'' arises from the discrepancy between neutron lifetime measurements obtained using the beam method, which measures decay products, and the bottle method, which measures the disappearance of neutrons. To resolve…
The NEXT-White detector, a high-pressure gaseous xenon time projection chamber, demonstrated the excellence of this technology for future neutrinoless double beta decay searches using photomultiplier tubes (PMTs) to measure energy and…
Modern PET systems reach a spatial resolution of 3-10 mm. A disadvantage of this technique is the diffusion of the positron before its decay with a typical range of ca. 1 mm (depending on its energy). This motion and Compton scattering of…
The Jagiellonian Positron Emission Tomograph (J-PET) is a novel de- vice being developed at Jagiellonian University in Krakow, Poland based on or- ganic scintillators. J-PET is an axially symmetric and high acceptance scanner that can be…
Scanning Microwave Impedance Microscopy (MIM) measurement of photoconductivity with 50 nm resolution is demonstrated using a modulated optical source. The use of a modulated source allows for measurement of photoconductivity in a single…