Related papers: Cavity Ring-down Spectroscopy with behavior of Hyb…
Cavity ring-down spectroscopy is a ubiquitous optical method used to study light-matter interactions with high resolution, sensitivity and accuracy. However, it has never been performed with the multiplexing advantages of direct frequency…
Measuring low light absorption with combined uncertainty < 1 permille is crucial in a wide range of applications. Popular cavity ring-down spectroscopy can provide ultra-high precision, below 0.01 permille, but its accuracy is strongly…
Chiral molecules show differences in their chemical and optical properties due to different spatial arrangements of the atoms in the two enantiomers. A common way to optically differentiate them is to detect the disparity in the absorption…
Cavity ring-up spectroscopy (CRUS) provides an advanced technique to sense ultrafast phenomena, but there is no thorough discussion on its theory. Here we give a detailed theoretical analysis of CRUS with and without modal coupling, and…
Detection sensitivity is one of the most important attributes to consider during selection of spectroscopic techniques. However, high sensitivity alone is insufficient for spectroscopic measurements in spectrally congested regions.…
We report on a novel approach to cavity-ring-down spectroscopy with the sample gas in saturated-absorption regime. This technique allows to decouple and simultaneously retrieve empty-cavity background and absorption signal, by means of a…
Measurements of ultrahigh-fidelity absorption spectra can help validate quantum theory, engineer ultracold chemistry, and remotely sense atmospheres. Recent achievements in cavity-enhanced spectroscopy using either frequency-based…
Microresonators (MRs) are key components in integrated optics. As a result, the estimation of their energy storage capacity as measured by the quality factor (Q) is crucial. However, in MR with high/ultra-high Q, the surface-wall roughness…
We present a novel approach to cavity ring-down spectroscopy utilizing an optical frequency comb as the direct probe of the Fabry-Perot cavity, coupled with a time-resolved Fourier transform spectrometer for parallel retrieval of ring-down…
We demonstrate broadband and sensitive cavity ring-down spectroscopy using a near infrared frequency comb and a time-resolved Fourier transform spectrometer. The cavity decays are measured simultaneously and spectrally sorted, leading to…
A cavity ringdown system for probing the spatial variation of optical loss across high-reflectivity mirrors is described. This system is employed to examine substrate-transferred crystalline supermirrors and quantify the effect of…
Spectroscopy of whispering-gallery mode (WGM) microresonators has become a powerful scientific tool, enabling detection of single viruses, nanoparticles, and even single molecules. Yet the demonstrated timescale of these schemes has been…
We present a new cavity-based polarimetric scheme for highly sensitive and time-resolved measurements of birefringence and dichroism, linear and circular, that employs rapidly-pulsed single-frequency CW laser sources and extends current…
Monitoring of radiocarbon ($^{14}$C) in carbon dioxide is demonstrated using mid-infrared spectroscopy and a quantum cascade laser. The measurement is based on cavity ring-down spectroscopy, and a high sensitivity is achieved with a simple…
Radiocarbon's natural production, radiative decay, and isotopic rarity make it a unique tool to probe carbonaceous systems in the life and earth sciences. However, the difficulty of current radiocarbon ($^{14}$C) detection methods limits…
The Neutral Beam Injectors of the ITER experiment will rely on negative ion sources to produce 16.7 MW beams of H/D particles accelerated at 1 MeV. The prototype of these sources was built and is currently operated in the SPIDER experiment…
Cavity-enhanced direct frequency comb spectroscopy combines broad spectral bandwidth, high spectral resolution, precise frequency calibration, and ultrahigh detection sensitivity, all in one experimental platform based on an optical…
Liquid phase sensing applications at 1550~nm are highly desirable due to widely available off-the-shelf components. Generally, liquids at 1550~nm induce a high absorption loss that limits the overall sensor's sensitivity and detection…
Cavity ring-down is an essential test to measure ultra-high quality factor (UHQ) optical cavities, which is, however, frequently misinterpreted due to lacking of a specified analysis guideline. Here we clarify the basic property of cavity…
We present a modified approach to laser optical-feedback cavity-enhanced absorption spectroscopy. The technique involves continuously scanning the length of a high-finesse cavity to periodically lock a diode laser to the cavity resonance,…