Related papers: Strain sensitivity enhancement in a Grover-Michels…
We present a low-resource and robust optical implementation of the four-dimensional Grover coin, a four-port linear-optical scatterer that augments the low dimensionality of a regular beam-splitter. While prior realizations of the Grover…
Here we introduce interferometric devices by combining optical feedback (cavities) with unbiased multiports, which unlike traditional beam dividers, allow light to reflect back out of the port from which it originated. By replacing the…
Interferometric gravitational wave detectors are expected to be limited by shot noise at some frequencies. We experimentally demonstrate that a power recycled Michelson with squeezed light injected into the dark port can overcome this…
We report on the experimental combination of three advanced interferometer techniques for gravitational wave detection, namely power-recycling, detuned signal-recycling and squeezed field injection. For the first time we experimentally…
We propose a possible approach to achieve an 1/N sensitivity of Michelson interferometer by using a properly designed random phase modulation. Different from other approaches, the sensitivity improvement does not depend on increasing…
Gravitational waves reaching a Michelson interferometer are expected to induce a very small change in the length of its arms causing a phase shift between them, but it is very difficult to observe the extremely small phase shift signals…
Ground-based gravitational wave detectors use laser interferometry to detect the minuscule distance change between test masses caused by gravitational waves. Stray light that scatters back into the interferometer causes transient signals…
We calculate the response of an ideal Michelson interferometer incorporating both dual recycling and squeezed light to gravitational waves. The photon counting noise has contributions from the light which is sent in through the input ports…
Application of the large scale gravitational wave interferometers for measurement of geophysical signals at very low frequencies is considered. Analysis is concentrated on the mechanism of penetration of quasistatic geophysical perturbation…
We propose a new interferometer technique for high precision phase measurements such as those in gravitational wave detection. The technique utilizes a pair of optically coupled resonators that provides identical resonance conditions for…
An extension of the input-output relation for a conventional Michelson interferometric gravitational-wave detector is carried out to treat an arbitrary coherent state for the injected optical beam. This extension is one of necessary…
Grover multiports are higher-dimensional generalizations of beam splitters, in which input to any one of the four ports has equal probability of exiting at any of the same four ports, including the input port. In this paper, we demonstrate…
High-precision measurements are crucial for testing the fundamental laws of nature and for advancing the technological frontier. Clock interferometry, where particles with an internal clock are coherently split and recombined along two…
We present an approach to experimentally evaluate gravity gradient noise, a potentially limiting noise source in advanced interferometric gravitational wave (GW) detectors. In addition, the method can be used to provide sub-percent…
The binary neutron star coalescence GW170817 was observed by gravitational wave detectors during the inspiral phase but sensitivity in the 1-5 kHz band was insufficient to observe the expected nuclear matter signature of the merger itself,…
We present an overview of quantum noise in gravitational wave interferometers. Gravitational wave detectors are extensively modified variants of a Michelson interferometer and the quantum noise couplings are strongly influenced by the…
The sensitivity of next-generation gravitational-wave detectors such as Advanced LIGO and LCGT should be limited mostly by quantum noise with an expected technical progress to reduce seismic noise and thermal noise. Those detectors will…
We examined the output of a quantum Michelson interferometer incorporating the combined effects of nonlinear optomechanical interaction and time-varying gravitational fields. Our findings indicate a deviation from the standard relationship…
We present a Michelson-type microwave interferometer for use in ferromagnetic resonance experiments. The interferometer is capable of broadband operation without manual adjustment of phase delay or amplitude attenuation. A prototype of the…
We demonstrate a nontraditional design of the Sagnac interferometer by replacing the commonly used beam splitter with a linear-optical Grover multiport. This substitution creates a pole at the origin of the device parameter space with an…