English
Related papers

Related papers: Design and Performance Simulation of the Electroma…

200 papers

The EIC Comprehensive Chromodynamics Experiment (ECCE) detector has been designed to address the full scope of the proposed Electron Ion Collider (EIC) physics program as presented by the National Academy of Science and provide a deeper…

Instrumentation and Detectors · Physics 2024-07-23 J. K. Adkins , Y. Akiba , A. Albataineh , M. Amaryan , I. C. Arsene , C. Ayerbe Gayoso , J. Bae , X. Bai , M. D. Baker , M. Bashkanov , R. Bellwied , F. Benmokhtar , V. Berdnikov , J. C. Bernauer , F. Bock , W. Boeglin , M. Borysova , E. Brash , P. Brindza , W. J. Briscoe , M. Brooks , S. Bueltmann , M. H. S. Bukhari , A. Bylinkin , R. Capobianco , W. -C. Chang , Y. Cheon , K. Chen , K. -F. Chen , K. -Y. Cheng , M. Chiu , T. Chujo , Z. Citron , E. Cline , E. Cohen , E. Conroy , T. Cormier , Y. Corrales Morales , C. Cotton , J. Crafts , C. Crawford , S. Creekmore , C. Cuevas , J. Cunningham , G. David , C. T. Dean , M. Demarteau , S. Diehl , N. Doshita , R. Dupré , J. M. Durham , R. Dzhygadlo , R. Ehlers , L. El Fassi , A. Emmert , R. Ent , C. Fanelli , R. Fatemi , S. Fegan , M. Finger , M. Finger , J. Frantz , M. Friedman , I. Friscic , D. Gangadharan , S. Gardner , K. Gates , F. Geurts , R. Gilman , D. Glazier , E. Glimos , Y. Goto , N. Grau , S. V. Greene , A. Q. Guo , L. Guo , C. Gwenian , S. K. Ha , J. Haggerty , T. Hayward , X. He , O. Hen , D. W. Higinbotham , M. Hoballah , T. Horn , A. Hoghmrtsyan , P. -h. J. Hsu , J. Huang , G. Huber , A. Hutson , K. Y. Hwang , C. E. Hyde , M. Inaba , T. Iwata , H. S. Jo , K. Joo , N. Kalantarians , G. Kalicy , K. Kawade , S. J. D. Kay , A. Kim , B. Kim , C. Kim , M. Kim , Y. Kim , Y. Kim , E. Kistenev , V. Klimenko , S. H. Ko , I. Korover , W. Korsch , G. Krintiras , S. Kuhn , C. -M. Kuo , T. Kutz , J. Lajoie , D. Lawrence , S. Lebedev , H. Lee , J. S. H. Lee , S. W. Lee , Y. -J. Lee , W. Li , W. Li , X. Li , X. Li , Y. T. Liang , S. Lim , C. -H. Lin , D. X. Lin , K. Liu , M. X. Liu , K. Livingston , N. Liyanage , W. J. Llope , C. Loizides , E. Long , R. -S. Lu , Z. Lu , W. Lynch , D. Marchand , M. Marcisovsky , C. Markert , P. Markowitz , H. Marukyan , P. McGaughey , M. Mihovilovic , R. G. Milner , A. Milov , Y. Miyachi , A. Mkrtchyan , P. Monaghan , R. Montgomery , D. Morrison , A. Movsisyan , H. Mkrtchyan , A. Mkrtchyan , C. Munoz Camacho , M. Murray , K. Nagai , J. Nagle , I. Nakagawa , C. Nattrass , D. Nguyen , S. Niccolai , R. Nouicer , G. Nukazuka , M. Nycz , V. A. Okorokov , S. Orešić , J. D. Osborn , C. O'Shaughnessy , S. Paganis , Z Papandreou , S. F. Pate , M. Patel , C. Paus , G. Penman , M. G. Perdekamp , D. V. Perepelitsa , H. Periera da Costa , K. Peters , W. Phelps , E. Piasetzky , C. Pinkenburg , I. Prochazka , T. Protzman , M. L. Purschke , J. Putschke , J. R. Pybus , R. Rajput-Ghoshal , J. Rasson , B. Raue , K. Read , K. Røed , R. Reed , J. Reinhold , E. L. Renner , J. Richards , C. Riedl , T. Rinn , J. Roche , G. M. Roland , G. Ron , M. Rosati , C. Royon , J. Ryu , S. Salur , N. Santiesteban , R. Santos , M. Sarsour , J. Schambach , A. Schmidt , N. Schmidt , C. Schwarz , J. Schwiening , R. Seidl , A. Sickles , P. Simmerling , S. Sirca , D. Sharma , Z. Shi , T. -A. Shibata , C. -W. Shih , S. Shimizu , U. Shrestha , K. Slifer , K. Smith , D. Sokhan , R. Soltz , W. Sondheim , J. Song , J. Song , I. I. Strakovsky , P. Steinberg , P. Stepanov , J. Stevens , J. Strube , P. Sun , X. Sun , K. Suresh , V. Tadevosyan , W. -C. Tang , S. Tapia Araya , S. Tarafdar , L. Teodorescu , D. Thomas , A. Timmins , L. Tomasek , N. Trotta , R. Trotta , T. S. Tveter , E. Umaka , A. Usman , H. W. van Hecke , C. Van Hulse , J. Velkovska , E. Voutier , P. K. Wang , Q. Wang , Y. Wang , Y. Wang , D. P. Watts , N. Wickramaarachchi , L. Weinstein , M. Williams , C. -P. Wong , L. Wood , M. H. Wood , C. Woody , B. Wyslouch , Z. Xiao , Y. Yamazaki , Y. Yang , Z. Ye , H. D. Yoo , M. Yurov , N. Zachariou , W. A. Zajc , J. Zhang , Y. Zhang , Y. X. Zhao , X. Zheng , P. Zhuang

The CMS electromagnetic calorimeter (ECAL) is a high-resolution, hermetic, and homogeneous calorimeter made of 75,848 scintillating lead tungstate crystals. Following the discovery of the Higgs boson, the CMS ECAL is at the forefront of…

Instrumentation and Detectors · Physics 2015-10-12 Andrea Massironi

The Electron-Ion Collider (EIC) is a next-generation particle accelerator facility designed to probe the fundamental structure of matter such as the origins of nucleon mass, spin, and the dynamic behavior of quarks and gluons within nucleon…

Instrumentation and Detectors · Physics 2026-05-18 Jeongsu Bok

The electromagnetic calorimeter (ECAL) of the AMS-02 experiment is a 3-dimensional sampling calorimeter, made of lead and scintillating fibers. The detector allows for a high granularity, with 18 samplings in the longitudinal direction, and…

The Multi-Purpose Detector (MPD) is designed to study a hot and dense baryonic matter formed in heavy-ion collisions at SQRT(sNN)=4-11 GeV at the NICA accelerator complex (Dubna, Russia). Large-sized electromagnetic calorimeter (ECal) of…

A highly granular silicon-tungsten electromagnetic calorimeter (SiW-ECAL) is the reference design of the ECAL of the International Large Detector (ILD) concept, one of the two detector concepts for the detector(s) at the future…

Instrumentation and Detectors · Physics 2020-06-17 D. Breton , A. Irles , J. Jeglot , J. Maalmi , R. Pöschl , D. Zerwas

Lepton scattering is an established ideal tool for studying inner structure of small particles such as nucleons as well as nuclei. As a future high energy nuclear physics project, an Electron-ion collider in China (EicC) has been proposed.…

The next generation experiment in high energy particle physics will be International Linear Collider of electron and positron at the TeV scale. The experiment is aim to search the Higgs particle and to measure its properties. The physics…

Instrumentation and Detectors · Physics 2015-03-13 Elmaddin Guliyev

The ALICE detector at the LHC (A Large Ion Collider Experiment) will carry out comprehensive measurements of high energy nucleus-nucleus collisions, in order to study QCD matter under extreme conditions and the phase transtion between…

Instrumentation and Detectors · Physics 2019-08-14 Rene Bellwied

High precision physics at future colliders as the International Linear Collider (ILC) require unprecedented high precision in the determination of the energy of final state particles. The needed precision will be achieved thanks to the…

Instrumentation and Detectors · Physics 2018-02-27 Adrián Irles

Studies of the response of the SiD silicon-tungsten electromagnetic calorimeter (ECal) are presented. Layers of highly granular (13 mm^2 pixels) silicon detectors embedded in thin gaps (~ 1 mm) between tungsten alloy plates give the SiD…

Instrumentation and Detectors · Physics 2017-03-28 Amanda Steinhebel , James Brau

We present a design for a high-granularity calorimeter insert for future experiments at the Electron-Ion Collider (EIC). The sampling-calorimeter design uses scintillator tiles read out with silicon photomultipliers. It maximizes coverage…

The highly granular silicon-tungsten electromagnetic calorimeter (SiW ECAL) is the reference design of the ECAL for the International Large Detector (ILD) concept, one of the two detector concepts proposed for the future International…

Instrumentation and Detectors · Physics 2020-06-24 Adrian Irles

Calorimeters are a crucial component in modern particle detectors. They are responsible for providing accurate energy measurements of particles produced in high-energy collisions. The demanding requirements set for next-generation collider…

Instrumentation and Detectors · Physics 2025-12-15 Bruno Rodrigues , Inês Ochoa , Agostinho Gomes

The performance of the Baby Barrel Electromagnetic Calorimeter (Baby BCAL) - a small-scale lead-scintillating-fiber (Pb/ScFi) prototype of the GlueX Barrel Electromagnetic Calorimeter (BCAL) - was tested in a dedicated beam campaign at the…

Shashlyk-type electromagnetic calorimeter (ECal) of the Multi-Purpose Detector at heavy-ion NICA collider is optimized to provide precise spatial and energy measurements for photons and electrons in the energy range from about 40 MeV to 2-3…

Instrumentation and Detectors · Physics 2020-06-24 A. Yu. Semenov , I. A. Semenova , M. Bhattacharjee , A. Durum , Yu. Krechetov , V. Kulikov , I. Mamonov , M. Martemianov

This paper presents mechanical R&D for the CALICE Silicon-tungsten electromagnetic calorimeter. After the physics ECAL prototype, tested in 2006 (DESY-CERN), 2007 (CERN), 2008 (FNAL) and before the design of different "modules 0" (barrel…

Instrumentation and Detectors · Physics 2010-06-23 Denis Grondin , Daniel Jeans

The International Large Detector (ILD) is a proposed detector for the International Linear Collider (ILC). It has been designed to achieve an excellent jet energy resolution by using Particle Flow Algorithms (PFA), which rely on the ability…

The CALICE collaboration has constructed highly granular electromagnetic and hadronic calorimeter prototypes to evaluate technologies for the use in detector systems at the future International Linear Collider. These calorimeters have been…

Instrumentation and Detectors · Physics 2019-08-13 Frank Simon