Related papers: 3D space-variant modal deconvolution with computed…
The aberrations in an optical microscope are commonly measured and corrected at one location in the field of view, within the so-called isoplanatic patch. Full-field correction is desirable for high-resolution imaging of large specimens.…
This paper proposes a non-computational method of counteracting the effect of image degradation introduced by the diffraction phenomenon in lensless microscopy. All the optical images (whether focused by lenses or not) are diffraction…
Fluorescence microscopy images usually show severe anisotropy in axial versus lateral resolution. This hampers downstream processing, i.e. the automatic extraction of quantitative biological data. While deconvolution methods and other…
Inverse problems in image reconstruction are fundamentally complicated by unknown noise properties. Classical iterative deconvolution approaches amplify noise and require careful parameter selection for an optimal trade-off between…
We present a novel method for generating 3D garment deformations from given body poses, which is key to a wide range of applications, including virtual try-on and extended reality. To simplify the cloth dynamics, existing methods mostly…
We consider the problem of joint three-dimensional (3D) localization and material classification of unresolved space debris using a multispectral rotating point spread function (RPSF). The use of RPSF allows one to estimate the 3D locations…
Diffusion models generate images with an unprecedented level of quality, but how can we freely rearrange image layouts? Recent works generate controllable scenes via learning spatially disentangled latent codes, but these methods do not…
Self-supervised methods have recently proved to be nearly as effective as supervised ones in various imaging inverse problems, paving the way for learning-based approaches in scientific and medical imaging applications where ground truth…
Ultrasound is widely used in medical diagnostics allowing for accessible and powerful imaging but suffers from resolution limitations due to diffraction and the finite aperture of the imaging system, which restricts diagnostic use. The…
We introduce a superresolution technique that combines spatial mode demultiplexing (SPADE) with emitter blinking. We show that temporal fluctuations not only enhance the precision of SPADE imaging, but also drastically simplify the…
We have shown that the left side null space of the autoregression (AR) matrix operator is the lexicographical presentation of the point spread function (PSF) on condition the AR parameters are common for original and blurred images. The…
Recent years have witnessed the emergence and increasing popularity of 3D medical imaging techniques with the development of 3D sensors and technology. However, achieving geometric invariance in the processing of 3D medical images is…
In this paper we investigate the application of optimisation techniques in the deconvolution of mineral fractionation data obtained from a mathematical model for the operation of a fluidised bed with a set of inclined parallel channels…
Adaptive optics (AO) corrected ood imaging of the retina is a popular technique for studying the retinal structure and function in the living eye. However, the raw retinal images are usually of poor contrast and the interpretation of such…
We describe a "spatio-spectral" deconvolution algorithm for wide-band imaging in radio interferometry. In contrast with the existing multi-frequency reconstruction algorithms, the proposed method does not rely on a model of the…
In this paper, we present a novel deep method to reconstruct a point cloud of an object from a single still image. Prior arts in the field struggle to reconstruct an accurate and scalable 3D model due to either the inefficient and expensive…
In recent years, there has been a proliferation of wide-field sky surveys to search for a variety of transient objects. Using relatively short focal lengths, the optics of these systems produce undersampled stellar images often marred by a…
The spatial resolution of astronomical images is limited by atmospheric turbulence and diffraction in the telescope optics, resulting in blurred images. This makes it difficult to accurately measure the brightness of blended objects because…
Point-spread function (PSF) estimation in spatially undersampled images is challenging because large pixels average fine-scale spatial information. This is problematic when fine-resolution details are necessary, as in optimal photometry…
In this paper we propose a blind deconvolution method which applies to data perturbed by Poisson noise. The objective function is a generalized Kullback-Leibler divergence, depending on both the unknown object and unknown point spread…