English
Related papers

Related papers: MPGD with a 3D-printed Thick-GEM as sole gain elem…

200 papers

Multiple-GEM detectors are considered to be good candidates for tracking devices in experiments with high hadronic background. We present the results of the triple-GEM detectors beam test in a high intensity pion beam. The detectors had an…

Instrumentation and Detectors · Physics 2007-05-23 A. Bondar , A. Buzulutskov , L. Shekhtman , A. Sokolov , A. Vasiljev

A study has been carried out to evaluate the performance stability of Gas Electron Multiplier (GEM) chamber prototypes in the laboratory using $^{55}$Fe radiation source with Argon and CO$_2$ gas mixture. This research focuses on the…

Instrumentation and Detectors · Physics 2026-04-10 S. Mandal , S. Gope , S. Das , S. Biswas

In recent years important progress in micropattern gaseous detectors has been achieved in the use of resistive material to build compact spark-protected devices. The novel idea presented here consists of the polarisation of WELL structures…

Instrumentation and Detectors · Physics 2015-03-19 Rui De Oliveira , Marcello Maggi , Archana Sharma

We present results on THGEM operation at low gas pressures, in the range 0.5-50 Torr. Gaseous gain up to 100000 was recorded at 10 Torr of Isobutane in a single multiplier element, with pulses rise-time in the few ns range. Cascaded…

Instrumentation and Detectors · Physics 2019-08-15 C. K. Shalem , R. Chechik , A. Breskin , K. Michaeli , N. Ben-Haim

We further study the performance of single, double and triple Gas Electron Multiplier (GEM) detectors in pure noble gases at high pressures, in the range of 1-10 atm. We confirm that light noble gases, in particular He and its mixtures with…

Instrumentation and Detectors · Physics 2015-06-26 V. Aulchenko , A. Bondar , A. Buzulutskov , L. Shekhtman , R. Snopkov , Yu. Tikhonov

We present an original design for large area gaseous detectors based on the MICROMEGAS technology. This technology incorporates an insulating grid, sandwiched between the micro-mesh and the anode-pad plane, which provides an uniform 200…

Instrumentation and Detectors · Physics 2016-08-16 D. Bernard , H. Delagrange , D. G. d'Enterria , M. Le Guay , G. Martínez , M. J. Mora , P. Pichot , D. Roy , Y. Schutz , A. Gandi , R. de Oliveira

A new family of spark-protected micropattern gaseous detectors is introduced: a 2-D sensitive restive microstrip counter and hybrid detectors, which combine in one design a resistive GEM with a microstrip detector. These novel detectors…

Instrumentation and Detectors · Physics 2011-08-31 P. Martinengo , E. Nappi , R. Oliveira , V. Peskov , P. Pietropaolo , P. Picchi

The Thick Gas Electron Multiplier (THGEM) is a robust high-gain gas-avalanche electron multiplier - a building block of a variety of radiation detectors. It can be manufactured economically by standard printed-circuit drilling and etching…

Instrumentation and Detectors · Physics 2023-03-03 Shikma Bressler , Luca Moleri , Abhik Jash , Andrea Tesi , Darina Zavazieva

Three Gas-Electron-Multiplier tracking detectors with an active area of 10 cm x 10 cm and a two-dimensional, laser-etched orthogonal strip readout have been tested extensively in particle beams at the Meson Test Beam Facility at Fermilab.…

Low pressure gaseous Negative Ion Time Projection Chambers (NITPCs) have been used previously by the DRIFT experiment to search for a directional Dark Matter (DM) signature. The main challenge with using a Negative Ion Drift (NID) gas…

Instrumentation and Detectors · Physics 2026-02-16 A. G. McLean , S. Higashino , R. R. Marcelo Gregorio , K. Miuchi , N. J. C. Spooner

We have developed microstrip gas counters manufactured on standard printed circuit board and having the following features: resistive cathode strips, thin (10 micron) metallic anode strips and electrodes protected against surface discharges…

Instrumentation and Detectors · Physics 2011-07-28 R. Oliveira , V. Peskov , F. Pietropaolo , P. Picchi

In view of a possible application as a charge-particle track readout for an Active Target Time Projection Chamber (AT-TPC), the operating properties of THick Gaseous Electron Multipliers (THGEM) in pure low-pressure Helium were…

Instrumentation and Detectors · Physics 2015-06-23 Marco Cortesi , John Yurkon , Andreas Stolz

A wire GEM (WGEM) detector with a gas gap between meshes was constructed. The detector provides the amplification 5x10E5 for the gas mixture of Ar +20% CO2 at atmospheric pressure. As compared with well-known GEM detectors produced by…

Instrumentation and Detectors · Physics 2009-11-26 B. M. Ovchinnikov , V. I. Razin , A. I. Reshetin , S. N. Filippov

UV lasers for the calibration of gaseous detectors have seen newfound employment with current-generation micro-pattern gaseous detectors (MPGDs), especially those devices not suitable for tests with traditional sources (e.g. cosmic rays or…

Instrumentation and Detectors · Physics 2020-04-06 Antonello Pellecchia , Antonio Ranieri , Piet Verwilligen

In this work, we study the response of single layer Thick GEM (THGEM) detector to p/${\pi^+}$ at E3 line of Beijing Test Beam Facility. In our experiment, the drift gap of THGEM Detector is 4mm, and the working gas is Ar/3% iso. Result…

Simulation of new generation gas detectors is rendered complicated due to the non-trivial nature of the electric field and simultaneous presence of several length-scales. Computation of the electrostatic field, however, is extremely…

Instrumentation and Detectors · Physics 2007-05-23 S. Mukhopadhyay , N. Majumdar

The new beam profile measurement for the Antiproton Decelerator (AD) at CERN is based on a single Gas Electron Multiplier (GEM) with a 2D readout structure. This detector is very light (~0.4% X0), and measures horizontal and vertical…

Instrumentation and Detectors · Physics 2012-03-20 Serge Duarte Pinto , Rhodri Jones , Leszek Ropelewski , Jens Spanggaard , Gerard Tranquille

We present the results of the first in-beam studies of a medium size (10$\times$10 cm$^2$) Resistive-Plate WELL (RPWELL): a single-sided THGEM coupled to a pad anode through a resistive layer of high bulk resistivity ($\sim$10$^9…

Muon tomography based on the measurement of multiple scattering of atmospheric cosmic ray muons is a promising technique for detecting and imaging heavily shielded high-Z nuclear materials such as enriched uranium. This technique could…

Instrumentation and Detectors · Physics 2016-11-17 K. Gnanvo , B. Benson , W. Bittner , F. Costa , L. Grasso , M. Hohlmann , J. B. Locke , S. Martoiu , H. Muller , M. Staib , A. Tarazona , J. Toledo

Controlled etching of copper electrodes in Gas Electron Multiplier foils allows a reduction of the material budget by more than a factor of two for a triple-GEM detector. Detectors making use of thinned foils provide performances similar to…

Instrumentation and Detectors · Physics 2008-11-26 A. Bondar , A. Buzulutskov , R. de Oliveira , L. Ropelewski , F. Sauli , L. Shekhtman
‹ Prev 1 3 4 5 6 7 10 Next ›