English
Related papers

Related papers: Data sorting modes of phoswich detector array

200 papers

In order to understand the performance of the PARIS (Photon Array for the studies with Radioactive Ion and Stable beams) detector, detailed characterization of two individual phoswich (LaBr$_3$(Ce)-NaI(Tl)) elements has been carried out.…

We have studied neutron response of PARIS phoswich [LaBr$_3$(Ce)-NaI(Tl)] detector which is being developed for measuring the high energy (E$_{\gamma}$ = 5 - 30 MeV) $\gamma$ rays emitted from the decay of highly collective states in atomic…

Instrumentation and Detectors · Physics 2017-08-23 Balaram Dey , C Ghosh , S. Pal , V. Nanal , R. G. Pillay , K. V. Anoop , M. S. Pose

The detection efficiency of phoswich detector starts to decrease when Compton scattering becomes significant. Events with energy deposit in both scintillators, if not rejected, are not useful for spectral analysis as the full energy of the…

Instrumentation and Detectors · Physics 2013-09-03 She Rui , Ji Jian-Feng , Feng Hua , Li Hong , Han Dong

In terms of energy resolution, temporal response to burst events, and thermal stability, lanthanum bromide doped with Ce is a much better choice than the traditional NaI(Tl) scintillator for hard X-ray astronomy. We present the test results…

Instrumentation and Methods for Astrophysics · Physics 2015-06-03 Hong Li , Jianfeng Ji , Hua Feng , Zhi Zhang , Dong Han

We present here a characterization of the low background NaI(Tl) crystal NaI-33 based on a period of almost one year of data taking (891 kgxdays exposure) in a detector configuration with no use of organic scintillator veto. This remarkably…

The GERDA experiment located at the LNGS searches for neutrinoless double beta (0\nu\beta\beta) decay of ^{76}Ge using germanium diodes as source and detector. In Phase I of the experiment eight semi-coaxial and five BEGe type detectors…

Instrumentation and Detectors · Physics 2013-12-09 M. Agostini , M. Allardt , E. Andreotti , A. M. Bakalyarov , M. Balata , I. Barabanov , M. Barnabe Heider , N. Barros , L. Baudis , C. Bauer , N. Becerici-Schmidt , E. Bellotti , S. Belogurov , S. T. Belyaev , G. Benato , A. Bettini , L. Bezrukov , T. Bode , V. Brudanin , R. Brugnera , D. Budjáš , A. Caldwell , C. Cattadori , A. Chernogorov , F. Cossavella , E. V. Demidova , A. Domula , V. Egorov , R. Falkenstein , A. Ferella , K. Freund , N. Frodyma , A. Gangapshev , A. Garfagnini , C. Gotti , P. Grabmayr , V. Gurentsov , K. Gusev , K. K. Guthikonda , W. Hampel , A. Hegai , M. Heisel , S. Hemmer , G. Heusser , W. Hofmann , M. Hult , L. V. Inzhechik , L. Ioannucci , J. Janicskó Csáthy , J. Jochum , M. Junker , T. Kihm , I. V. Kirpichnikov , A. Kirsch , A. Klimenko , K. T. Knöpfle , O. Kochetov , V. N. Kornoukhov , V. V. Kuzminov , M. Laubenstein , A. Lazzaro , V. I. Lebedev , B. Lehnert , H. Y. Liao , M. Lindner , I. Lippi , X. Liu , A. Lubashevskiy , B. Lubsandorzhiev , G. Lutter , C. Macolino , A. A. Machado , B. Majorovits , W. Maneschg , M. Misiaszek , I. Nemchenok , S. Nisi , C. O'Shaughnessy , L. Pandola , K. Pelczar , G. Pessina , A. Pullia , S. Riboldi , N. Rumyantseva , C. Sada , M. Salathe , C. Schmitt , J. Schreiner , O. Schulz , B. Schwingenheuer , S. Schönert , E. Shevchik , M. Shirchenko , H. Simgen , A. Smolnikov , L. Stanco , H. Strecker , M. Tarka , C. A. Ur , A. A. Vasenko , O. Volynets , K. von Sturm , V. Wagner , M. Walter , A. Wegmann , T. Wester , M. Wojcik , E. Yanovich , P. Zavarise , I. Zhitnikov , S. V. Zhukov , D. Zinatulina , K. Zuber , G. Zuzel

Detector efficiency determination is essential to correct the measured yields and extract reliable cross sections of particles emitted in nuclear reactions. We investigate the efficiencies for measuring the full energies of light charged…

Instrumentation and Detectors · Physics 2017-02-01 P. Morfouace , W. G. Lynch , M. B. Tsang

The P326 experiment at the CERN SPS has been proposed with the purpose of measuring the branching ratio for the decay K^+ \to \pi^+ \nu \bar{\nu} to within 10%. The photon veto system must provide a rejection factor of 10^8 for \pi^0…

High-resolution array detectors are widely used in single-particle tracking, but their performance is limited by excess noise from background light and dark current. As pixel resolution increases, the diminished signal per pixel exacerbates…

Quantum Physics · Physics 2025-12-16 Chao-Ning Hu , Jun Xin , Xiao-Ming Lu

A study of identification properties of a Si-Si DE-E telescope exploiting an underdepleted residual-energy detector has been performed. Five different bias voltages have been used, one corresponding to full depletion, the others associated…

Point-contact p-type high-purity germanium detectors (PPC HPGe) are particularly suited for detection of sub-keV nuclear recoils from coherent elastic scattering of neutrinos or light dark matter particles. While these particles are…

High-purity germanium detectors are widely used in rare-event searches due to their excellent energy resolution and extremely high intrinsic (radio)purity. In experiments searching for neutrinoless double beta decay in $^{76}$Ge such as…

Instrumentation and Detectors · Physics 2026-05-14 Alex Biondi , Krzysztof Szczepaniec , Tomasz Mróz , Marcin Misiaszek , Grzegorz Zuzel

The branching ratio (BR) for the decay K^+ \rightarrow \pi^+ \nu \bar{\nu} is a sensitive probe for new physics. The NA62 experiment at the CERN SPS will measure this BR to within about 10%. To reject the dominant background from channels…

To meet the need for a high counting rate and high time resolution in future high-energy physics experiments, a prototype of a gas photodetector with an RPC structure was developed. Garfield++ simulated the detector's performance, and the…

Instrumentation and Detectors · Physics 2024-07-30 Yiding Zhao , D. Hu , M. Shao , Y. Zhou , S. Lv , Xiangqi Tian , Anqi Wang , Xueshen Lin , Hao Pang , Y. Suna

In experiments searching for neutrinoless double-beta decay, the possibility of identifying the two emitted electrons is a powerful tool in rejecting background events and therefore improving the overall sensitivity of the experiment. In…

The response of an array of plastic phoswich detectors to ions of $1\le Z\le 18$ has been measured from $E/A$=12 to 72 MeV. The detector response has been parameterized by a three parameter fit which includes both quenching and high energy…

Nuclear Experiment · Physics 2009-10-28 D. Fox , D. R. Bowman , G. C. Ball , A. Galindo-Uribarri , E. Hagberg , D. Horn , L. Beaulieu , Y. Larochelle

The $\beta$ decay of one-neutron halo nucleus $^{11}$Be was investigated using the Warsaw Optical Time Projection Chamber (OTPC) detector to measure $\beta$-delayed charged particles. The results of two experiments are reported. In the…

We present a new detection scheme for rejecting backgrounds in neutrino less double beta decay experiments. It relies on the detection of Cherenkov light emitted by electrons in the MeV region. The momentum threshold is tuned to reach a…

Instrumentation and Detectors · Physics 2015-05-20 Ioannis Giomataris

Seismic noise with an amplitude higher than that of the sought signal is a challenge for detection. Several techniques have been developed to suppress the ambient noise and to reduce the detection threshold in order to find signals with the…

Geophysics · Physics 2026-04-27 Ivan Kitov
‹ Prev 1 2 3 10 Next ›