English
Related papers

Related papers: Technical assessment of a novel vertical CT system…

200 papers

Proton computed tomography (CT) is similar to x-ray CT but relies on protons rather than photons to form an image. In its most common operation mode, the measured quantity is the amount of energy that a proton has lost while traversing the…

Medical Physics · Physics 2022-08-17 Nils Krah , Denis Dauvergne , Jean Michel Létang , Simon Rit , Étienne Testa

Accurate dose calculation on cone beam computed tomography (CBCT) images is essential for modern proton treatment planning workflows, particularly when accounting for inter-fractional anatomical changes in adaptive treatment scenarios.…

Computed tomography (CT) scans are a major source of medical radiation exposure worldwide. In countries like China, the frequency of CT scans has grown rapidly, particularly in routine physical examinations where chest CT scans are…

Medical Physics · Physics 2025-04-10 Zirui Ye , Bei Yao , Haoran Zheng , Li Tao , Ripeng Wang , Yankui Chang , Zhi Chen , Yingming Zhao , Wei Wei , Xie George Xu

Proton Computed Tomography (pCT) provides a promising solution to enhance the accuracy of Relative Stopping Power (RSP) required for proton therapy planning. This research introduces a novel high-granularity pCT architecture that…

Purpose: The purpose of this work is to develop a new approach for high spatial resolution dosimetry based on Raman micro-spectroscopy scanning of radiochromic film (RCF). We generate dose calibration curves over an extended dose range from…

Medical Physics · Physics 2021-09-15 Connor Mcnairn , Iymad Mansour , Bryan Muir , Rowan M. Thomson , Sangeeta Murugkar

In this work, we proposed virtual imaging simulators as an alternative approach to experimental validation of beam range uncertainty in complex patient geometry using a computational model of a human head and a photon-counting CT scanner.…

Medical Physics · Physics 2026-01-05 S. Vrbaški , G. Stanić , S. Molinelli , M. Bhattarai , E. Abadi , M. Ciocca , E. Samei

While drastic improvements in CT technology have occurred in the past 25 years, spatial resolution is one area where progress has been limited until recently. New photon counting CT systems, are capable of much better spatial resolution…

Background: X-ray grating-based dark-field imaging can sense the small angle scattering caused by an object's micro-structure. This technique is sensitive to lung's porous alveoli and is able to detect lung disease at an early stage. Up to…

Medical Physics · Physics 2024-05-03 Peiyuan Guo , Simon Spindler , Li Zhang , Zhentian Wang

Purpose: The physical properties of yttrium-90 (90Y) allow for imaging with positron emission tomography/computed tomography (PET/CT). The increased sensitivity of long axial field-of-view (LAFOV) PET/CT scanners possibly allows to overcome…

Purpose. - Radiotherapy is an important treatment for prostate cancer.During treatment sessions, bladder and rectal repletion is difficult to quantify and cannot be measured with a single and initial CT scan acquisition. Some methods, such…

Medical Physics · Physics 2011-04-06 Cyril Voyant , Katia Biffi , Leschi Delphine , Jerome Briancon , Celine Lantieri Marcovici

We conducted a multi-institutional audit of dosimetric variability between FLASH and conventional dose rate (CONV) electron irradiations by using an anatomically realistic 3D-printed mouse phantom. A CT scan of a live mouse was used to…

Objective: This study aims to develop and validate a novel framework, iPhantom, for automated creation of patient-specific phantoms or digital-twins (DT) using patient medical images. The framework is applied to assess radiation dose to…

With the increasing complexity of external beam therapy, so-called "end-to-end" tests are intended to cover all steps from therapy planning to follow-up to fulfill the high demands on quality assurance. As magnetic resonance imaging (MRI)…

Purpose: Radiotherapy commonly relies on CT, but there is growing interest in using hybrid PET/MR. Therefore, dedicated hardware setups have been proposed for PET/MR systems which enable imaging in radiotherapy treatment position. These…

Medical Physics · Physics 2024-11-14 R. M. Winter , O. Engelsen , O. J. Bratting , N. Brekke , J. Sæterstøl , O. Sæther , K. R. Redalen

This study develops and validates a patient-specific Monte Carlo (MC) dosimetry framework for propagation-based phase-contrast breast CT (BCT) at the Imaging and Medical Beamline (IMBL), ANSTO Australian Synchrotron, for accurate mean…

The Centers for Medicare & Medicaid Services (CMS) has introduced CMS1074v2, a quality measure for computed tomography (CT) that assesses radiation dose and image quality across 18 CT exam categories. This measure mandates the calculation…

Medical Physics · Physics 2025-03-11 Gary Y Ge , Charles M Weaver , Jie Zhang

7 Tesla (7T) apparent diffusion coefficient (ADC) maps derived from diffusion-weighted imaging (DWI) demonstrate improved image quality and spatial resolution over 3 Tesla (3T) ADC maps. However, 7T magnetic resonance imaging (MRI)…

Medical Physics · Physics 2023-11-28 Zach Eidex , Jing Wang , Mojtaba Safari , Eric Elder , Jacob Wynne , Tonghe Wang , Hui-Kuo Shu , Hui Mao , Xiaofeng Yang

Purpose: To experimentally validate the Fastcat cone beam CT (CBCT) simulator against kV and MV CBCT images acquired with a Varian Truebeam linac. Methods: kV and MV CBCT images of a Catphan 504 phantom were acquired using a 100 kVp beam…

Medical Physics · Physics 2022-01-19 Jericho O'Connell , Clayton Lindsay , Magdalena Bazalova-Carter

Background: Perfusion computed tomography (CT) images the dynamics of a contrast agent through the body over time, and is one of the highest X-ray dose scans in medical imaging. Recently, a theoretically justified reconstruction algorithm…

Medical Physics · Physics 2026-02-04 Namhoon Kim , Ashwin Pananjady , Amir Pourmorteza , Sara Fridovich-Keil

Objective: Quantify geometric and dosimetric accuracy of a novel prostate MR-to-MR deformable image registration (DIR) approach to support MR-guided adaptive radiation therapy dose accumulation. Approach: We evaluated DIR accuracy in 25…