Related papers: Boron Nitride Coatings for the Enhanced Detection …
Measuring slow neutrons is difficult when the radiation field also contains charged particles and fast neutrons, especially when the radiation composition is not known in advance. In this work, we present a tested method to measure slow…
This article describes the design features and the first test measurements obtained during the installation of a novel high resolution 2D neutron detection technique. The technique proposed in this work consists of a boron layer (enriched…
In this paper a new type of passive neutron detector based on the already existing one, CR39, is described. Its operation was verified by three different neutron sources: an Americium-Beryllium (Am241-Be) source; a TRIGA type nuclear…
We report reproducible track-detector signals consistent with slow neutron capture events, recorded in D$_2$O electrolysis involving D-Pd deposited on Pt cathode. Sensitivity to slow neutrons was achieved using boron-coated CR-39 (BCR)…
A new boron-coated CCD camera is described for direct detection of ultracold neutrons (UCN) through the capture reactions $^{10}$B (n,$\alpha$0$\gamma$)$^7$Li (6%) and $^{10}$B(n,$\alpha$1$\gamma$)$^7$Li (94%). The experiments, which extend…
For the first time, the neutron optical wall-potential of natural cubic boron nitride (cBN) was measured at the ultracold neutron (UCN) source of the research reactor TRIGA Mainz using the time-of-flight method (TOF). The samples…
A new neutron detection concept is presented that is based on superconductive niobium (Nb) strips coated by a boron (B) layer. The working principle of the detector relies on the nuclear reaction 10B+n $\rightarrow$ $\alpha$+ 7Li , with…
Several improvements were made for Nuclear Track Detectors (NTDs) used for environmental studies and for particle searches. A new method was used to determine the bulk etch rate of CR39 and Makrofol NTDs. It is based on the simultaneous…
We propose an alternative approach for the detection of fast neutrons in the energy range from 10-4 to 5 MeV based on 10B-RPCs (hybrid double-gap Resistive Plate Chambers with 10B4C neutron converters) surrounded by a polyethylene…
The results of an experimental feasibility study of a position sensitive thermal neutron detector based on a resistive plate chamber (RPC) are presented. The detector prototype features a thin-gap (0.35 mm) hybrid RPC with an aluminium…
A new technique for detection of slow neutrons with gaseous detectors using ultra-thin layers with 10B atoms is presented. The reaction between a thermal neutron and a 10B atom releases 2 secondary particles, namely a 7Li ion and an alpha…
A new type of cold/ultracold neutron detector that can realize a spatial resolution of less than 100 nm was developed using nuclear emulsion. The detector consists of a fine-grained nuclear emulsion coating and a 50-nm thick $^{10}$B$_4$C…
In this study, we have developed a new sub-MeV neutron detector that has a high position resolution, energy resolution, directional sensitivity, and low background. The detector is based on a super-fine-grained nuclear emulsion, called the…
Neutron detection efficiency of superheated drops of Freon22 for neutrons obtained from a 3Ci Am-Be neutron source has been reported in this paper. Neutron detection efficiency of both F-22 and F-12 have been determined from the measured…
In this paper we demonstrate that it is possible to produce low cost neutron-sensitive detectors using stereo-lithography additive manufacturing. A curable scintillating resin is made by mixing BN:ZnS with a commercially available UV resin.…
We report on the development of a 10B conversion layer optimized for ultra-cold neutron detection with silicon detectors. The efficiency of this layer is high and roughly uniform over a large ultra-cold neutron velocity range. The designed…
An efficient neutron detection system with good energy resolution is required to correctly characterize decays of neutron-rich nuclei where $\beta-$delayed neutron emission is a dominant decay mode. The Neutron dEtector with Xn Tracking…
A multilayer surface detector for ultracold neutrons (UCNs) is described. The top $^{10}$B layer is exposed to the vacuum chamber and directly captures UCNs. The ZnS:Ag layer beneath the $^{10}$B layer is a few microns thick, which is…
Resistive plate chambers (RPC) lined with $^{10}B_{4}$C neutron converters is a promising cost effective technology for position-sensitive thermal neutron detection capable to outperform $^{3}$He-based detectors in terms of spatial…
The present supply of 3He can no longer meet the detector demands of the upcoming ESS facility and continued detector upgrades at current neutron sources. Therefore viable alternative technologies are required to support the development of…