Related papers: Sampling Density Compensation using Fast Fourier D…
Quarter sampling is a novel sensor design that allows for an acquisition of higher resolution images without increasing the number of pixels. When being used for video data, one out of four pixels is measured in each frame. Effectively,…
Density reconstruction from X-ray projections is an important problem in radiography with key applications in scientific and industrial X-ray computed tomography (CT). Often, such projections are corrupted by unknown sources of noise and…
Cardiac magnetic resonance imaging is a valuable non-invasive tool for identifying cardiovascular diseases. For instance, Cine MRI is the benchmark modality for assessing the cardiac function and anatomy. On the other hand, multi-contrast…
Cardiac magnetic resonance imaging (MRI) requires reconstructing a real-time video of a beating heart from continuous highly under-sampled measurements. This task is challenging since the object to be reconstructed (the heart) is…
Ultrasound reflection tomography is widely used to image large complex specimens that are only accessible from a single side, such as well systems and nuclear power plant containment walls. Typical methods for inverting the measurement rely…
Incoherent k-space undersampling and deep learning-based reconstruction methods have shown great success in accelerating MRI. However, the performance of most previous methods will degrade dramatically under high acceleration factors, e.g.,…
Convolutional Neural Networks are the de facto models for image recognition. However 3D CNNs, the straight forward extension of 2D CNNs for video recognition, have not achieved the same success on standard action recognition benchmarks. One…
Multimode fibers (MMFs) have the potential to carry complex images for endoscopy and related applications, but decoding the complex speckle patterns produced by mode-mixing and modal dispersion in MMFs is a serious challenge. Several groups…
Diffusion models achieve remarkable quality in image generation, but at a cost. Iterative denoising requires many time steps to produce high fidelity images. We argue that the denoising process is crucially limited by an accumulation of the…
Various applications such as MRI, solution of PDEs, etc. need to perform an inverse nonequispaced fast Fourier transform (NFFT), i. e., compute $M$ Fourier coefficients from given $N$ nonequispaced data. In the present paper we consider…
Neural implicit reconstruction via volume rendering has demonstrated its effectiveness in recovering dense 3D surfaces. However, it is non-trivial to simultaneously recover meticulous geometry and preserve smoothness across regions with…
The reconstruction of density and velocity fields is of central importance to the interpretation of $N$-body simulations. We propose a phase-space extension of the Delaunay tessellation field estimator (DTFE) that tracks the dark matter…
Marine Controlled Source Electromagnetic (CSEM) is employed both in large-scale geophysical applications as well as within exploration of hydrocarbons and gas hydrates. Due to the diffusive character of the EM field only very low…
Magnetic Resonance Imaging (MRI) is the gold standard for measuring fat and iron content non-invasively in the body via measures known as Proton Density Fat Fraction (PDFF) and $R_2^*$, respectively. However, conventional PDFF and $R_2^*$…
This paper proposes a general framework for internal patch-based image restoration based on Conditional Random Fields (CRF). Unlike related models based on Markov Random Fields (MRF), our approach explicitly formulates the posterior…
A reduced-bias nonparametric estimator of the cumulative distribution function (CDF) and the survival function is proposed using infinite-order kernels. Fourier transform theory on generalized functions is utilized to obtain the improved…
This work addresses the problem of estimating proton density and T1 maps from two partially sampled K-space scans such that the total acquisition time remains approximately the same as a single scan. Existing multi parametric non linear…
Compared to light-field microscopy (LFM), which enables high-speed volumetric imaging but suffers from non-uniform spatial sampling, Fourier light-field microscopy (FLFM) introduces sub-aperture division at the pupil plane, thereby ensuring…
Reconstruction of PET images is an ill-posed inverse problem and often requires iterative algorithms to achieve good image quality for reliable clinical use in practice, at huge computational costs. In this paper, we consider the PET…
Given the recent advances with image-generating algorithms, deep image completion methods have made significant progress. However, state-of-art methods typically provide poor cross-scene generalization, and generated masked areas often…