Related papers: Digital Low-Level RF system for the Linac Electron…
The proposed Next Linear Collider (NLC) contains linac systems operating at L,S,C, and X band. This paper describes a wideband modular low-level RF (LLRF) system applicable for all NLC pulsed RF systems. High speed digital IF techniques are…
Incremental upgrades of the legacy low level RF (LLRF) equipment-50 years for the Los Alamos Neutron Science Center (LANSCE)-involves challenges and problems not seen with new and total replacement opportunities. The digital LLRF upgrade at…
The Low-Level RF (LLRF) control circuits of linear accelerators (LINACs) are conventionally realized with heterodyne based architectures, which have analog RF mixers for up and down conversion with discrete data converters. We have…
Low Level RF (LLRF) control systems of linear accelerators (LINACs) are typically implemented with heterodyne based architectures, which have complex analog RF mixers for up and down conversion. The Gen 3 Radio Frequency System-on-Chip…
The Advanced Light Source (ALS) at LBNL is upgrading several LLRF systems for its Linac and Sub-Harmonic Bunchers, where it is desired to have a unified LLRF system design to support various RF frequencies (at 125MHz, 500MHz and 3GHz) and…
The first version of digital low level RF (DLLRF) for the Diamond Light Source storage ring and booster was developed with ALBA Synchrotron. Six systems have been built so far. Two of them are in routine operation controlling two normal…
At the end of the Large Hadron Collider's Run 2, CERN's Proton Injector Linac 2, commissioned in 1978, delivered its final beam in December 2018. For Run 3, from March 2021, a new H$^{-}$ will take over the role: Linac4. The machine has…
The Source Development Lab (SDL) at BNL consists of a 230 MeV electron linac and a 10 m long wiggler for short wavelength Free Electronic Laser (FEL) development. The original control system [1] was based on the one in use at the National…
CEA is committed to the design, construction and commissioning of a Medium Energy Beam Transfer line and a superconducting linac (SCL) for SARAF accelerator in order to accelerate 5mA beam of either protons from 1.3 MeV to 35 MeV or…
The LIGHT (Linac for Image-Guided Hadron Therapy) project was initiated to develop a modular proton accelerator delivering beam with energies up to 230 MeV for cancer therapy. The machine consists of three different kinds of accelerating…
We have commissioned the digital Low Level RF (LLRF) system for storage ring RF at Advanced Light Source at Lawrence Berkeley National Lab (LBNL). The system is composed of 42 synchronous sampling channels for feedback control, diagnostics,…
A compact low-level RF (LLRF) control system based on RF system-on-chip (RFSoC) technology has been designed for the Advanced Concept Compact Electron Linear-accelerator (ACCEL) program, which has challenging requirements in both RF…
The J-PARC linac was consist of 324MHz low-{\beta} section and 972MHz high-{\beta} section. There is a total of 48 stations. And each station was equipped with an independent LLRF (Low-Level Radio Frequency) system to realize an…
PIP-II is an 800 MEV superconducting linac that is in the initial acceleration chain for the Fermilab accelerator complex. The RF system consists of a warm front-end with an ion source, RFQ and buncher cavities along with 25 superconducting…
The linear accelerator (LINAC) at the Los Alamos Neu-tron Science Center (LANSCE) consists of Pre-buncher, Main-Buncher, low-energy beam transport (LEBT), four 201.25-MHz Drift Tube Linacs (DTLs) and forty-four 805-MHz Coupled Cavity Linacs…
SPARC_LAB is a high-brightness electron photoinjector dedicated to FEL radiation production and research on novel acceleration techniques. It has been in operation at LNF since 2005. It is composed of a newly designed brazeless 1.6-cell…
The China spallation neutron source (CSNS) linac is designed with beam energy of 81MeV and a peak current of 15mA in the first phase. The RF power system for the 81 MeV Linac requires 8 units of RF power sources, each unit has one…
The Low Frequency Instrument (LFI) is a radiometer array covering the 30-70 GHz spectral range on-board the ESA Planck satellite, launched on May 14th, 2009 to observe the cosmic microwave background (CMB) with unprecedented precision. In…
Louisiana State University Center for Advanced Microstructures and Devices (CAMD) began a control system upgrade project in early 1997. At the time, the storage ring was controlled by a VAX/VMS system, primarily using CAMAC for I/O. The…
PIP-II is a superconducting linac that is in the initial acceleration chain for the Fermilab accelerator complex. The RF system consists of a warm front-end with an RFQ and buncher cavities along with 25 superconducting cryo-modules…