Related papers: Towards a compact transportable optical clock base…
We present the design of a compact optical clock based on the $^2S_{1/2} \rightarrow ^2D_{3/2}$ 435.5 nm transition in $^{171}$Yb$^+$. The ion trap will be based on a micro-fabricated circuit, with surface electrodes generating a trapping…
The paper describes the results achieved in the development of the compact transportable fully automated optical clock based on a single 171Yb+ ion in a radiofrequency (RF) quadrupole trap. The resulted measurements demonstrated the 4.9E-16…
We experimentally investigate an optical frequency standard based on the 467 nm (642 THz) electric-octupole reference transition 2S1/2(F=0) -> F7/2(F=3) in a single trapped 171Yb+ ion. The extraordinary features of this transition result…
The highest performance atomic clocks are based on interrogation of ultra-narrow optical transitions. There is now significant interest in developing these systems as a source of GNSS-independent time in deployed, dynamic environments. We…
This dissertation reports on the development of a low-power, high-stability miniature atomic frequency standard based on 171Yb+ ions. The ions are buffer-gas cooled and held in a linear quadrupole trap that is integrated into a sealed,…
We present a novel method for engineering an optical clock transition that is robust against external field fluctuations and is able to overcome limits resulting from field inhomogeneities. The technique is based on the application of…
Singly-ionized ytterbium, with ultra-narrow optical clock transitions at 467 nm and 436 nm, is a convenient system for the realization of optical atomic clocks and tests of present-day variation of fundamental constants. We present the…
We describe experiments with an optical frequency standard based on a laser cooled $^{171}$Yb$^+$ ion confined in a radiofrequency Paul trap. The electric-quadrupole transition from the $^2S_{1/2}(F=0)$ ground state to the $^2D_{3/2}(F=2)$…
We have measured the frequency of the $6s^2S_{1/2} - 5d^2D_{3/2}$ electric-quadrupole transition of $^{171}$Yb$^+$ with a relative uncertainty of $1\times 10^{-14}$, $\nu_{Yb}$ = 688 358 979 309 312 Hz $\pm$ 6 Hz. A femtosecond frequency…
Extra-laboratory atomic clocks are necessary for a wide array of applications (e.g. satellite-based navigation and communication). Building upon existing vapor cell and laser technologies, we describe an optical atomic clock, designed…
A transportable optical clock refer to the $4s^2S_{1/2}-3d^2D_{5/2}$ electric quadrupole transition at 729 nm of single $^{40}Ca^+$ trapped in mini Paul trap has been developed. The physical system of $^{40}Ca^+$ optical clock is…
In this paper, we propose a scheme of active ion optical clock with detailed pumping method, lasing states, output power, linewidth and light shift. Using 171Yb+ ions in a Paul Trap we propose to utilize a Fabry-Perot resonator to realize…
A full evaluation of the uncertainty budget for the ytterbium ion optical clock at the National Physical Laboratory (NPL) was performed on the electric octupole (E3) $^2\mathrm{S}_{1/2}\,\rightarrow\, ^2\mathrm{F}_{7/2}$ transition. The…
For the past 15 years, tremendous progress within the fields of laser stabilization, optical frequency combs and atom cooling and trapping have allowed the realization of optical atomic clocks with unrivaled performances. These instruments…
Recent experimental progress in cooling, trapping, and quantum logic spectroscopy of highly-charged ions (HCIs) made HCIs accessible for high resolution spectroscopy and precision fundamental studies. Based on these achievements, we explore…
Optical atomic clocks demonstrate a better stability and lower systematic uncertainty than the highest performance microwave atomic clocks. However, the best performing optical clocks have a large footprint in a laboratory environment and…
We used Precise Point Positioning, a well-established GPS carrier-phase frequency transfer method to perform a direct remote comparison of two optical frequency standards based on single laser-cooled $^{171}$Yb$^+$ ions operated at NPL, UK…
Optical lattice clocks surpass primary Cs microwave clocks in frequency stability and accuracy, and are promising candidates for a redefinition of the second in the International System of Units (SI). However, the robustness of optical…
We report calculations designed to assess the ultimate precision of an atomic clock based on the 578 nm $6 ^1S_0 --> 6 ^3P^o_0$ transition in Yb atoms confined in an optical lattice trap. We find that this transition has a natural linewidth…
With the advent of optical clocks featuring fractional frequency uncertainties on the order of $10^{-17}$ and below, new applications such as chronometric levelling with few-cm height resolution emerge. We are developing a transportable…