Related papers: Constraints on inelastic dark matter from the CDEX…
The XENON100 experiment, in operation at the Laboratori Nazionali del Gran Sasso in Italy, is designed to search for dark matter WIMPs scattering off 62 kg of liquid xenon in an ultra-low background dual-phase time projection chamber. In…
Direct detection of Weakly Interacting Massive Particle (WIMP) candidates of Dark Matter (DM) is studied within the context of a self-consistent truncated isothermal model of the finite-size dark halo of the Galaxy based on the "King model"…
The LUX collaboration new results advance the search for dark matter candidate particles in the 4 GeV/c^2 and higher mass range, with a maximal spin-independent 90% C.L. limit of 2 x 10^-46 cm^2 at 50 GeV/c^2 for its 332 live-day run,…
We present a systematic halo-independent analysis of available Weakly Interacting Massive Particles (WIMP) direct detection data within the framework of Inelastic Dark Matter (IDM). We show that, when the smallest number of assumptions is…
We present formalism necessary to determine weak-scale matching coefficients in the computation of scattering cross sections for putative dark matter candidates interacting with the Standard Model. Particular attention is paid to the…
Guided by the non-relativistic effective field theory of interactions between Weakly Interacting Massive Particles (WIMPs) of spin 1/2 and nuclei we study direct detection exclusion plots for an example of non-standard spin-dependent…
Heavy WIMP (weakly-interacting-massive-particle) effective field theory is used to compute the WIMP-nucleon scattering rate for general heavy electroweak multiplets through order $m_W/M$, where $m_W$ and $M$ denote the electroweak and WIMP…
The CRESST-II cryogenic Dark Matter search, aiming at detection of WIMPs via elastic scattering off nuclei in CaWO$_4$ crystals, completed 730 kg days of data taking in 2011. We present the data collected with eight detector modules, each…
We reconsider the discovery limit of multi-ton direct detection dark matter experiments in the light of recent measurements of the coherent elastic neutrino-nucleus scattering process. Assuming the cross section to be a parameter entirely…
We report on WIMP search results in the XENON100 detector using a non-relativistic effective field theory approach. The data from science run II (34 kg $\times$ 224.6 live days) was re-analyzed, with an increased recoil energy interval…
We perform a generalized analysis of data from WIMP search experiments for point-like WIMPs of arbitrary spin and general Lorenz-invariant WIMP-nucleus interaction. We show that in the non-relativistic limit only spin-independent (SI) and…
We present LUXCalc, a new utility for calculating likelihoods and deriving WIMP-nucleon coupling limits from the recent results of the LUX direct search dark matter experiment. After a brief review of WIMP-nucleon scattering, we derive LUX…
In the earlier work on the development of a model-independent data analysis method for determining the mass of Weakly Interacting Massive Particles (WIMPs) by using measured recoil energies from direct Dark Matter detection experiments…
Dark matter (DM) direct detection experiments have been setting strong limits on the DM-nucleon scattering cross section at the DM mass above a few GeV, but leave large parameter space unexplored in the low mass region. DM is likely to be…
Light WIMP dark matter and hidden sector dark matter have been proposed to explain the DAMA, CoGeNT and CRESST-II data. Both of these approaches feature spin independent elastic scattering of dark matter particles on nuclei. Light WIMP dark…
The discovery of a Standard Model-like Higgs boson and the hitherto absence of evidence for other new states may indicate that if WIMPs comprise cosmological dark matter, they are heavy compared to electroweak scale particles, $M \gg…
We report experimental upper limits on WIMP-nucleon elastic scattering cross sections from the second science run of ZEPLIN-III at the Boulby Underground Laboratory. A raw fiducial exposure of 1,344 kg.days was accrued over 319 days of…
The EDELWEISS collaboration has performed a direct search for WIMP dark matter using a 320 g heat-and-ionization cryogenic Ge detector operated in a low-background environment in the Laboratoire Souterrain de Modane. No nuclear recoils are…
We present first significant limits on WIMP dark matter by the phonon-light technique, where combined phonon and light signals from a scintillating cryogenic detector are used. Data from early 2004 with two 300 g CRESST-II prototype…
The CoGeNT and CRESST WIMP direct detection experiments have recently observed excesses of nuclear recoil events, while the DAMA/LIBRA experiment has a long standing annual modulation signal. It has been suggested that these excesses may be…