Related papers: Low-energy single-electron detector with sub-micro…
We develop single-photon detectors comprising single-mode fiber-coupled superconducting nanowires, with high system detection efficiencies at a wavelength of 940 nm. The detector comprises a 6.5-nm-thick, 110-nm-wide NbN nanowire meander…
The elastic and inelastic high--energy small--angle electron--positron scattering is considered. All radiative corrections to the cross--section with the relative accuracy $\delta\sigma/ \sigma = 0.1 \% $ are explicitly taken into account.…
Dependence of the secondary electron yield (SEY) from the primary beam incident energy and the coverage has been measured for neon, argon, krypton and xenon condensed on a target at 4.2K. The beam energy ranged between 100 eV and 3 keV, the…
Detailed measurements of the electron performance of the ATLAS detector at the LHC are reported, using decays of the Z, W and J/psi particles. Data collected in 2010 at sqrt(s)=7 TeV are used, corresponding to an integrated luminosity of…
Designed as a high-sensitivity gamma-ray observatory, the Fermi Large Area Telescope is also an electron detector with a large acceptance exceeding 2m^2 sr at 300 GeV. Building on the gamma-ray analysis, we have developed an efficient…
We present constraints on low-mass dark matter electron scattering and absorption interactions using a SuperCDMS high-voltage eV-resolution (HVeV) detector. Data were taken underground in the NEXUS facility located at Fermilab with an…
We investigate the possibility of non-destructive electron diffraction imaging of a single molecule to determine its structure. The molecular specimen will be held on a free-standing sheet of graphene. Due to the high conductivity of…
It is challenging to achieve high precision energy resolution for large liquid scintillator detectors. Energy non-uniformity is one of the main obstacles. To surmount it, a calibration-data driven method was developed previously to…
A low-energy electronic recoil calibration of XENON1T, a dual-phase xenon time projection chamber, with an internal $^{37}$Ar source was performed. This calibration source features a 35-day half-life and provides two mono-energetic lines at…
Using scanning gate microscopy (SGM), we probe the scattering between a beam of electrons and a two-dimensional electron gas (2DEG) as a function of the beam's injection energy, and distance from the injection point. At low injection…
In this article, we report on the development of a time-of-flight based electron energy analyzer capable of measuring the 3-D momentum and energy distributions of very low energy (meV-scale) photoemitted electrons. This analyzer is capable…
The tagging system of the KEDR detector is a symmetrical focusing magnetic spectrometer for electrons and positrons scattered at small angles; it is embedded into the lattice of the VEPP-4M collider and intended for two-photon processes…
We present a gated silicon single photon detector based on a commercially available avalanche photodiode. Our detector achieves a photon detection efficiency of 45\pm5% at 808 nm with 2x 10^-6 dark count per ns at -30V of excess bias and…
We demonstrate superconducting nanowire single photon detectors with 76 +/- 4 % system detection efficiency at a wavelength of 315 nm and an operating temperature of 3.2 K, with a background count rate below 1 count per second at saturated…
Silicon Drift Detectors, widely employed in high-resolution and high-rate X-ray applications, are considered here with interest also for electron detection. The accurate measurement of the tritium beta decay is the core of the TRISTAN…
Electron spin resonance (ESR) spectroscopy is the method of choice for characterizing paramagnetic impurities, with applications ranging from chemistry to quantum computing, but it gives access only to ensemble-averaged quantities due to…
An experimental test of the electron energy scale linearities of SNO+ and EJ-301 scintillators was carried out using a Compton spectrometer with electrons in the energy range 0.09-3 MeV. The linearity of the apparatus was explicitly…
A simplified digital spectrometer for the study of $\gamma$-rays with energies up to $\sim100$ MeV is presented and tested. The spectrometer is only consisted of a fast digital oscilloscope and three scintillation detectors which can work…
We demonstrate the real-time detection of single photogenerated electrons in two different lateral double quantum dots made in AlGaAs/GaAs/AlGaAs quantum wells having a thin or a thick AlGaAs barrier layer. The observed incident laser power…
Single-shot absorption measurements have been performed using the multi-keV X-rays generated by a laser wakefield accelerator. A 200 TW laser was used to drive a laser wakefield accelerator in a mode which produced broadband electron beams…