English
Related papers

Related papers: CCAT: Mod-Cam Cryogenic Performance and its Impact…

200 papers

We have fabricated an array of subgap kinetic inductance detectors (SKIDs) made of granular aluminum ($T_c\sim$2~K) sensitive in the 80-90 GHz frequency band and operating at 300~mK. We measure a noise equivalent power of…

Instrumentation and Detectors · Physics 2021-04-07 F. Levy-Bertrand , A. Benoît , O. Bourrion , M. Calvo , A. Catalano , J. Goupy , F. Valenti , N. Maleeva , L. Grünhaupt , I. M. Pop , A. Monfardini

The Epoch of Reionization Spectrometer (EoR-Spec) is an upcoming Line Intensity Mapping (LIM) instrument designed to study the evolution of the early universe (z = 3.5 to 8) by probing the redshifted [CII] 158 $\mu$m fine-structure line…

We present the design and validation of a variable temperature cryogenic blackbody source, hereinafter called a cold load, that will be used to characterize detectors to be deployed by CMB-S4, the next-generation ground-based cosmic…

Instrumentation and Methods for Astrophysics · Physics 2025-01-07 Cesiley L. King , Ian Gullet , Adam J. Anderson , Bradford A. Benson , Rick Bihary , Haichen Fan , Johanna M. Nagy , Hogan Nguyen , John E. Ruhl , Sara M. Simon

The photon detection system of the first far detector (FD1-HD) of the DUNE experiment will detect scintillation photons produced by particle interactions in a kiloton-scale liquid Argon time projection chamber. The photon detectors of…

We report on state-of-the-art scanning probe microscopy measurements performed in a pulse tube based top-loading closed-cycle cryostat with a base temperature of 4 K and a 9 T magnet. We decoupled the sample space from the mechanical and…

Far-infrared (far-IR) astrophysics missions featuring actively cooled telescopes will offer orders of magnitude observing speed improvement at wavelengths where galaxies and forming planetary systems emit most of their light. The PRobe…

Kinetic Inductance Detectors (KIDs) are superconductive low$-$temperature detectors useful for astrophysics and particle physics. We have developed arrays of lumped elements KIDs (LEKIDs) sensitive to microwave photons, optimized for the…

We describe an alternating current method to measure the Nernst effect in superconducting thin films at low temperatures. The Nernst effect is an important tool in the understanding superconducting fluctuations and, in particular, vortex…

Superconductivity · Physics 2020-10-28 Yuxiao Wu , Aviad Frydman , Arnab Roy

Low-temperature detectors often use mechanical coolers as part of the cooling chain in order to reach sub-Kelvin operating temperatures. The microphonics noise caused by the mechanical coolers is a general and inherent issue for these…

Instrumentation and Methods for Astrophysics · Physics 2023-03-03 R. Imamura , H. Awaki , M. Tsujimoto , S. Yamada , F. S. Porter , C. A. Kilbourne , R. L. Kelley , Y. Takei

We demonstrate a prototype kinetic inductance detector (KID) readout system that uses less than 10 mW per pixel. The CCAT-prime RFSoC based readout is capable of reading four independent detector networks of up to 1000 KIDs each. The power…

Instrumentation and Methods for Astrophysics · Physics 2023-05-02 Adrian K. Sinclair , James R. Burgoyne , Yaqiong Li , Cody Duell , Scott C. Chapman , Anthony I. Huber , Ruixuan Xie

The ATHENA X-ray Observatory is the second large-class mission in the ESA Cosmic Vision 2015-2025 science programme. One of the two on-board instruments is the X-IFU, an imaging spectrometer based on a large array of TES microcalorimeters.…

Instrumentation and Methods for Astrophysics · Physics 2018-07-24 Matteo D'Andrea , Claudio Macculi , Andrea Argan , Simone Lotti , Gabriele Minervini , Luigi Piro , Michele Biasotti , Dario Corsini , Flavio Gatti , Guido Torrioli

We present a cryogenic microwave noise source with a characteristic impedance of 50 $\Omega$, which can be installed in a coaxial line of a cryostat. The bath temperature of the noise source is continuously variable between 0.1 K and 5 K…

The prevalent use of large volume liquid argon detectors strongly motivates the development of novel readout and monitoring technology which functions at cryogenic temperatures. This paper presents the development of a cryogenic CMOS camera…

Instrumentation and Detectors · Physics 2017-04-05 Nicola McConkey , Neil Spooner , Matthew Thiesse , Michael Wallbank , Thomas Karl Warburton

MAIA, a three-channel imager targeting fast cadence photometry, was recently installed on the Mercator telescope (La Palma, Spain). This instrument observes a 9.4 x 14.1 arcmin field of view simultaneously in three color bands ($u$, $g$ and…

Instrumentation and Methods for Astrophysics · Physics 2013-11-05 Gert Raskin , Johan Morren , Wim Pessemier , Jesus Perez Padilla , Jeroen Vandersteen

This paper describes the setup and the results of the direct on-wafer measurements of a FET noise parameters obtained with a source-pull method at temperatures down to T=4K and in the 5-12 GHz frequency range. The setup consists of a…

Instrumentation and Detectors · Physics 2026-05-19 Daniil Frolov , Jean-Olivier Plouchart , Utku Soylu

A vacuum compatible cryogenic accelerometer is presented which will reach $<0.5$ p$g$ Hz$^{-1/2}$ sensitivity from 1 mHz to 10 Hz with a maximum sensitivity of 10 f$g$ Hz$^{-1/2}$ around 10 Hz. This figure can be translated to a…

Applied Physics · Physics 2020-08-26 Joris Vincent van Heijningen

A new cryogenic noise calibration source for radio astronomy receivers is presented. Dissipated power is only 4.2 mW, allowing it to be integrated with the cold part of the receiver. Measured long-term stability, sensitivity to bias…

Instrumentation and Methods for Astrophysics · Physics 2011-09-19 Eric W. Bryerton

This paper presents pre-launch testing and calibration results for the SVOM/VT (Space-based Variable Objects Monitor, Visible Telescope) Flight Model (FM), validating its performance under simulated space conditions through thermal vacuum…

Optomechanical transduction harnesses the interaction between optical fields and mechanical motion to achieve sensitive measurement of weak mechanical quantities with inherently low noise. Lithium niobate combines low optical loss, strong…

The Probe far-Infrared Mission for Astrophysics (PRIMA) is a proposed space observatory which will use arrays of thousands of kinetic inductance detectors (KIDs) to perform low- and moderate-resolution spectroscopy throughout the…