English
Related papers

Related papers: Development of a time calibration system for the K…

200 papers

Accurate momentum determination of a neutral hadron, such as a KL meson or a neutron, remains a significant challenge in particle physics and nuclear physics experiments. The Belle II experiment presents an opportunity to address this…

We have developed a new laser-based time calibration system for highly segmented scintillator counters like the MEG II pixelated Timing Counter (pTC), consisting of 512-centimeter scale scintillator counters read out by silicon…

We have developed a new laser-based time calibration system for the MEG II timing counter dedicated to timing measurement of positrons. The detector requires precise timing alignment between $\sim\,$500 scintillation counters. In this…

Instrumentation and Detectors · Physics 2019-05-16 M. Nakao , G. Boca , P. W. Cattaneo , M. De Gerone , F. Gatti , M. Nishimura , W. Ootani , M. Rossella , Y. Uchiyama , M. Usami , K. Yoshida

Accurate Time-of-Flight (TOF) measurement with sub-100 picosecond resolution is a critical requirement for particle identification in future high-energy physics experiments, such as the Belle II $K_{L}$ and Muon (KLM) detector upgrade.…

Instrumentation and Detectors · Physics 2026-05-14 Ziyi Yang , Xiyang Wang , Shiming Zou , Ting Wang , Kairui Huang , Wanyi Zhuang , Yicheng Pu , Xiaolong Wang

A laser calibration system was developed for monitoring and calibrating time of flight (TOF) scintillating detector arrays. The system includes setups for both small- and large-scale scintillator arrays. Following test-bench…

Fast timing detectors are an essential element in the experimental setup for time-of-flight (ToF) mass measurements of unstable nuclei. We have upgraded the scintillator detectors used in experiments at the National Superconducting…

The design and tests of Timing Counter elements for the upgrade of the MEG experiment, MEG II,is presented. The detector is based on several small plates of scintillator with a Silicon PhotoMultipliers dual-side readout. The optimisation of…

Instrumentation and Detectors · Physics 2015-06-18 M. De Gerone , F. Gatti , W. Ootani , Y. Uchiyama , M. Nishimura , S. Shirabe , P. W. Cattaneo , M. Rossella

The Belle II detector at the SuperKEKB accelerator complex is covering a wide range of exciting physics topics. To achieve the project's research goals, a substantial increase of the data sample to 50~ab$^{-1}$ is needed, and for that, the…

High Energy Physics - Experiment · Physics 2022-11-28 Peter Krizan

A combination of scintillator, wavelength shifting (WLS) fiber, and silicon photomultiplier (SiPM) shows an excellent performance in the `$K_{L}$ and $\mu$ detector (KLM)' of the Belle II experiment. In this study, we present the R&D…

Instrumentation and Detectors · Physics 2024-05-22 Hongyu Zhang , Xiyang Wang , Weihu Ma , Shiming Zou , Deqing Fang , Wanbing He , Xiaolong Wang , Zhen Wang , Rui Yuan , Qibin Zheng

We have tested a prototype time-of-flight system based on bulk scintillator block of dimensions $2.5 \times 2.5 \times 200$ cm. Using a calibration scheme similar to the one used in actual collider experiments, we have achieved a resolution…

High Energy Physics - Experiment · Physics 2007-05-23 E. Chen , M. Saulnier , W. Sun , H. Yamamoto

A system based on commercially available items, such as a laser diode, emitting in the visible range $\sim 400$ nm,and multimode fiber patches, fused fiber splitters and optical switches may be assembled,for time calibration of…

Instrumentation and Detectors · Physics 2016-06-01 M. Bonesini , R. Bertoni , A. deBari , M. Rossella

The Belle detector operated at KEKb B-factory in 1999-2010 was one of the most remarkable experiments in the field of elementary particle physics of the last decades. The Belle successor, Belle II collaboration, is aimed to operate the…

Instrumentation and Detectors · Physics 2017-08-23 Timofey Uglov

This work explores the combination of liquid xenon as a scintillating medium and silicon photomultipliers as a readout in Positron Emission Tomography (PET) for enhanced Time-Of-Flight resolution. We present the results of our first…

The Muon $g-2$ experiment, E989, is currently taking data at Fermilab with the aim of reducing the experimental error on the muon anomaly by a factor of four and possibly clarifying the current discrepancy with the theoretical prediction. A…

Timing-pick up detectors with excellent timing resolutions are essential in many modern nuclear physics experiments. Aiming to develop a Time-Of-Flight system with precision down to about 10 ps, we have made a systematic study of the timing…

Instrumentation and Detectors · Physics 2016-04-19 J. W. Zhao , B. H. Sun , I. Tanihata , S. Terashima , L. H. Zhu , A. Enomoto , D. Nagae , T. Nishimura , S. Omika , A. Ozawa , Y. Takeuchi , T. Yamaguchi

The Belle II detector operating at the future upgrade to the KEKB accelerator will perform high-statistics precision investigations into the flavor sector of the Standard Model. As charged hadron identification is a vital element of the…

Instrumentation and Detectors · Physics 2019-08-14 K. Nishimura

The JSNS2-II (the second phase of JSNS2, J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) is an experiment aimed at searching for sterile neutrinos. This experiment has entered its second phase, employing two liquid…

A new muon and K_Long detector based on scintillators will be used for the endcap and inner barrel regions in the Belle II experiment, currently under construction. The increased luminosity of the e+e- SuperKEKB collider entails challenging…

A new timing detector measuring ~50 MeV/c positrons is under development for the MEG II experiment, aiming at a time resolution $\sigma_t \sim 30~\mathrm{ps}$. The resolution is expected to be achieved by measuring each positron time with…

Instrumentation and Detectors · Physics 2016-05-23 P. W. Cattaneo , M. De Gerone , F. Gatti , M. Nishimura , W. Ootani , M. Rossella , S. Shirabe , Y. Uchiyama