Related papers: Cryogenic geometric anti-spring vibration isolatio…
Suspended high-overtone bulk acoustic wave resonators (HBARs) can serve as a viable optomechanical platform for efficient transduction of signals from the microwave to the optical frequency domain. In contrast to 1D nanobeam optomechanical…
Suspension thermal modes in interferometric gravitational-wave detectors produce narrow, high-Q spectral lines that can contaminate gravitational searches and bias parameter estimation. In KAGRA, cryogenic mirrors are held by thick…
Cryogenic characterization of transition-edge sensor (TES) bolometers is a time- and labor-intensive process. As new experiments deploy larger and larger arrays of TES bolometers, the testing process will become more of a bottleneck. Thus…
This paper presents the design and benchmarking of cryogenic bulk-FETs using an experimentally calibrated TCAD framework that integrates 2-D electrostatics and interface-trap effects from $T = 2$ K to 300 K. For a 28-nm node device, carrier…
Silicon can be isotopically enriched, allowing for the fabrication of highly coherent semiconductor spin qubits. However, the conduction band of bulk Si exhibits a six-fold valley degeneracy, which may adversely impact the performance of…
An inertial sensor design is proposed in this paper to achieve high sensitivity and large dynamic range in the sub-Hz frequency regime. High acceleration sensitivity is obtained by combining optical cavity readout systems with…
The rising complexity of cutting-edge cryogenic systems is currently imposing challenging technical constraints to the monitoring of ultra-cold temperatures through standard commercially available sensors. Among different alternative…
Thermoacoustic Refrigerators use acoustic power for generating cold temperatures. Development of refrigerators based on the thermoacoustic technology is a novel solution to the present day need of cooling, without causing environmental…
Displacement sensors have a variety of applications within gravitational wave detectors. The seismic isolation chain of the LIGO core optics utilises optical shadow sensors for their stabilisation. Future upgrades, such as LIGO Voyager,…
We present simulations and a theoretical treatment of vertically vibrated granular media. The systems considered are confined in narrow quasi-two-dimensional and quasi-one-dimensional (column) geometries, where the vertical extension of the…
Recently, great progress has been made in the field of ultrasensitive microwave detectors, reaching even the threshold for utilization in circuit quantum electrodynamics. However, cryogenic sensors lack the compatibility with broad-band…
The effective frequency of a mechanical resonator can be tuned via the spring effect induced by quadratic optomechanical (QOM) coupling, and both spontaneous symmetry breaking and anti-parity-time phase transition were predicted in the QOM…
In recent decades, the laws of thermodynamics have been pushed down to smaller and smaller scales, within the field of stochastic thermodynamics and state-of-art experiments performed on mesoscopic systems. These measurements concern…
An electrostatic cryogenic storage ring, CSR, for beams of anions and cations with up to 300 keV kinetic energy per unit charge has been designed, constructed and put into operation. With a circumference of 35 m, the ion-beam vacuum…
For superconducting quantum processors, microwave signals are delivered to each qubit from room-temperature electronics to the cryogenic environment through coaxial cables. Limited by the heat load of cabling and the massive cost of…
We report a scanning superconducting quantum interference device (SQUID) microscope in a cryogen-free dilution refrigerator with a base temperature at the sample stage of at least 30 mK. The microscope is rigidly mounted to the mixing…
Bolometric experiments searching for rare events usually require an extremely low radioactive background to prevent spurious signals from mimicking those of interest, spoiling the sensitivity of the apparatus. In such contexts, radioactive…
We propose and test a cryogenic setup comprising dielectric waveguides for mm-wave frequencies in the range of 75-110 GHz and temperatures down to 10 mK. The targeted applications are quantum technologies at millimeter-wave frequencies,…
We have built a variable temperature scanning probe microscope (SPM) that covers 4.6 K - 180 K and up to 7 Tesla whose SPM head fits in a 52 mm bore magnet. It features a temperature-controlled sample stage thermally well isolated from the…
Cryogen-free low-temperature setups are becoming more prominent in experimental science due to their convenience and reliability, and concern about the increasing scarcity of helium as a natural resource. Despite not having any moving parts…