English
Related papers

Related papers: Full-scale Microwave SQUID Multiplexer Readout Sys…

200 papers

We present a new instrument composed of a large number of sub-electron noise Skipper-CCDs operated with a two stage analog multiplexed readout scheme suitable for scaling to thousands of channels. New, thick, $1.35$ Mpix sensors, from a new…

We have developed a flexible radio-frequency readout system suitable for a variety of superconducting detectors commonly used in millimeter and submillimeter astrophysics, including Kinetic Inductance detectors (KIDs), Thermal KID…

Instrumentation and Methods for Astrophysics · Physics 2019-09-04 Lorenzo Minutolo , Bryan Steinbach , Albert Wandui , Roger O'Brient

Current control techniques for cryogenically cooled qubits are realized with coaxial cables, posing multiple challenges in terms of cost, thermal load, size, and long-term scalability. Emerging approaches to tackle this issue include…

Quantum Physics · Physics 2025-10-01 Malek Succar , Mohamed I. Ibrahim

Quantum processing units will be modules of larger information processing systems containing also digital and analog electronics modules. Silicon-based quantum computing offers the enticing opportunity to manufacture all the modules using…

We report on the first integration of novel magnetic microcalorimeter detectors (MMCs), developed within SPARC (Stored Particles Atomic Physics Research Collaboration), into the experimental environment of storage rings at GSI, Darmstadt,…

We present the development of a second generation digital readout system for photon counting microwave kinetic inductance detector (MKID) arrays operating in the optical and near-IR wavelength bands. Our system retains much of the core…

At SRON we have been developing X-ray TES micro-calorimeters as backup technology for the X-ray Integral Field Unit (X-IFU) of the Athena mission, demonstrating excellent resolving powers both under DC and AC bias. We also developed a…

Instrumentation and Methods for Astrophysics · Physics 2025-06-04 D. Vaccaro , H. Akamatsu , L. Gottardi , M. de Wit , M. P. Bruijn , J. van der Kuur , K. Nagayoshi , E. Taralli , K. Ravensberg , J. R. Gao , J. W. A. den Herder

Superconducting microresonators have been successfully utilized as detection elements for a wide variety of applications. With multiplexing factors exceeding 1,000 detectors per transmission line, they are the most scalable low-temperature…

We have developed a modular interconnect platform for the control and readout of multiple solid-state qubits at cryogenic temperatures. The setup provides 74 filtered dc-bias connections, 32 control and readout connections with a bandwidth…

Mesoscale and Nanoscale Physics · Physics 2015-09-24 J. I. Colless , D. J. Reilly

The Skipper CCD-in-CMOS Parallel Read-Out Circuit (SPROCKET) is a mixed-signal front-end design for the readout of Skipper CCD-in-CMOS image sensors. SPROCKET is fabricated in a 65 nm CMOS process and each pixel occupies a 50$\mu$m $\times$…

Instrumentation and Detectors · Physics 2023-02-09 Adam Quinn , Manuel B. Valentin , Thomas Zimmerman , Davide Braga , Seda Memik , Farah Fahim

Nanoelectromechanical resonators have been successfully used for a variety of sensing applications. Their extreme resolution comes from their small size at the cost of low capture area, making the "needle in a haystack" issue acute. This…

Superconducting quantum computers require microwave control lines running from room temperature to the mixing chamber of a dilution refrigerator. Adding more lines without preliminary thermal modeling to make predictions risks overwhelming…

Quantum Physics · Physics 2025-12-16 Naomi Raicu , Tom Hogan , Xian Wu , Mehrnoosh Vahidpour , David Snow , Matthew Hollister , Mark Field

Future astrophysics and cosmic microwave background space missions operating in the far-infrared to millimetre part of the spectrum will require very large arrays of ultra-sensitive detectors in combination with high multiplexing factors…

Cosmic microwave background (CMB) measurements are fundamentally limited by photon statistics. Therefore, ground-based CMB observatories have been increasing the number of detectors that are simultaneously observing the sky. Thanks to the…

Instrumentation and Methods for Astrophysics · Physics 2020-03-18 T. de Haan , A. Suzuki , S. T. P. Boyd , R. H. Cantor , A. Coerver , M. A. Dobbs , R. Hennings-Yeomans , W. L. Holzapfel , A. T. Lee , G. I. Noble , G. Smecher , J. Zhou

As we have seen for digital camera market and a sensor resolution increasing to "megapixels", all the scientific and high-tech imagers (whatever the wave length - from radio to X-ray range) tends also to always increases the pixels number.…

Instrumentation and Detectors · Physics 2015-09-02 Damien Prêle

The third generation South Pole Telescope camera (SPT-3G) improves upon its predecessor (SPTpol) by an order of magnitude increase in detectors on the focal plane. The technology used to read out and control these detectors, digital…

Instrumentation and Methods for Astrophysics · Physics 2022-02-23 J. Montgomery , P. A. R. Ade , Z. Ahmed , E. Anderes , A. J. Anderson , M. Archipley , J. S. Avva , K. Aylor , L. Balkenhol , P. S. Barry , R. Basu Thakur , K. Benabed , A. N. Bender , B. A. Benson , F. Bianchini , L. E. Bleem , F. R. Bouchet , L. Bryant , K. Byrum , J. E. Carlstrom , F. W. Carter , T. W. Cecil , C. L. Chang , P. Chaubal , G. Chen , H. -M. Cho , T. -L. Chou , J. -F. Cliche , T. M. Crawford , A. Cukierman , C. Daley , T. de Haan , E. V. Denison , K. Dibert , J. Ding , M. A. Dobbs , D. Dutcher , T. Elleflot , W. Everett , C. Feng , K. R. Ferguson , A. Foster , J. Fu , S. Galli , A. E. Gambrel , R. W. Gardner , N. Goeckner-Wald , J. C. Groh , R. Gualtieri , S. Guns , N. Gupta , R. Guyser , N. W. Halverson , A. H. Harke-Hosemann , N. L. Harrington , J. W. Henning , G. C. Hilton , E. Hivon , W. L. Holzapfel , J. C. Hood , D. Howe , N. Huang , K. D. Irwin , O. B. Jeong , M. Jonas , A. Jones , T. S. Khaire , L. Knox , A. M. Kofman , M. Korman , D. L. Kubik , S. Kuhlmann , C. -L. Kuo , A. T. Lee , E. M. Leitch , A. E. Lowitz , C. Lu , S. S. Meyer , D. Michalik , M. Millea , A. Nadolski , T. Natoli , H. Nguyen , G. I. Noble , V. Novosad , Y. Omori , S. Padin , Z. Pan , P. Paschos , J. Pearson , C. M. Posada , K. Prabhu , W. Quan , A. Rahlin , C. L. Reichardt , D. Riebel , B. Riedel , M. Rouble , J. E. Ruhl , J. T. Sayre , E. Schiappucci , E. Shirokoff , G. Smecher , J. A. Sobrin , A. A. Stark , J. Stephen , K. T. Story , A. Suzuki , K. L. Thompson , B. Thorne , C. Tucker , C. Umilta , L. R. Vale , K. Vanderlinde , J. D. Vieira , G. Wang , N. Whitehorn , W. L. K. Wu , V. Yefremenko , K. W. Yoon , M. R. Young

Building large, cryogenic MKID arrays requires processing highly-multiplexed, wideband readout signals in real time; a task that has previously required large, heavy, and power-intensive custom electronics. In this work, we present the…

Instrumentation and Detectors · Physics 2024-06-17 Jennifer Pearl Smith , John I. Bailey , III. , Aled Cuda , Nicholas Zobrist , Benjamin A. Mazin

The realization of large-scale photonic circuit for quantum optics experiments at telecom wavelengths requires an increasing number of integrated detectors. Superconductive nanowire single photon detectors (SNSPDs) can be easily integrated…

A superconducting flux qubit is inductively coupled to a Superconducting QUantum Interference Device (SQUID) magnetometer, capacitively shunted to form a 1.294-GHz resonator. The qubit-state-dependent resonator frequency is weakly probed…

Superconductivity · Physics 2012-03-07 J. E. Johnson , E. M. Hoskinson , C. Macklin , D. H. Slichter , I. Siddiqi , John Clarke

The broad energy response, low electronic read noise, and good energy resolution have made X-ray Charge-Coupled Devices (CCDs) an obvious choice for developing soft X-ray astronomical instruments over the last half century. They also come…

‹ Prev 1 4 5 6 7 8 10 Next ›