English
Related papers

Related papers: Object independent scatter sensitivities for PET, …

200 papers

In computed tomography (CT) reconstruction, scattering causes server quality degradation of the reconstructed CT images by introducing streaks and cupping artifacts which reduce the detectability of low contrast objects. Monte Carlo (MC)…

Image and Video Processing · Electrical Eng. & Systems 2022-02-01 Ammar Alsaffar , Steffen Kieß , Kaicong Sun , Sven Simon

Due to its wide field of view, cone-beam computed tomography (CBCT) is plagued by large amounts of scatter, where attenuated photons hit the detector, and corrupt the linear models used for reconstruction. Given that one can generate a good…

Medical Physics · Physics 2017-07-06 Jonathan Mason , Alessandro Perelli , William Nailon , Mike Davies

We propose a new modeling approach for scatter estimation and descattering in polyenergetic X-ray computed tomography (CT) based on fitting models to local neighborhoods of a training set. X-ray CT is widely used in medical and industrial…

Image and Video Processing · Electrical Eng. & Systems 2021-09-30 Michael T. McCann , Marc L. Klasky , Jennifer L. Schei , Saiprasad Ravishankar

For long time non-pure beta emitters are avoided from PET imaging due to extra dose and increase in background from Compton scattering. But advent of high-resolution Compton camera system opens up new domain of imaging. Various non-pure…

Medical Physics · Physics 2021-10-06 Satyajit Ghosh , Pragya Das

Compared to single-source imaging systems, dual-source imaging systems equipped with two cross-distributed scanning beams significantly enhance temporal resolution and capture more comprehensive object scanning information. Nevertheless,…

Medical Physics · Physics 2025-03-19 Jianing Sun , Jigang Duan , Guangyin Li , Xu Jiang , Xing Zhao

Inter-crystal scattering (ICS) in Positron Emission Tomography (PET) is commonly regarded as a degradation effect that might compromise the image spatial resolution. In parallel, the inclusion of ICS events has also been recognized as a…

Medical Physics · Physics 2026-05-12 Jorge Roser , Hong Phuc Vo , Rebecca Kantorek , Steven Seeger , Magdalena Rafecas

In x-ray coherent scatter tomography, tomographic measurements of the forward scatter distribution are used to infer scatter densities within a volume. A radiopaque 2D pattern placed between the object and the detector array enables the…

Multi-MeV flash radiography is often used as the primary diagnostic technique for high energy and density (HED) physics experiments. Primary X-ray which is attenuated by the object offers density information of the object. For a thick metal…

Applied Physics · Physics 2021-12-02 Qinggang Jia , Peng-Cheng Mao , Yang-Bo , Dun-Fu Shi , Ling-Yu Zhang , Deng-Li , Hai-Bo Xu

Scatter can account for large errors in cone-beam CT (CBCT) due to its wide field of view, and its complicated nature makes its compensation difficult. Iterative polyenergetic reconstruction algorithms offer the potential to provide…

Medical Physics · Physics 2020-01-13 Jonathan H. Mason , Alessandro Perelli , William H. Nailon , Mike E. Davies

Deep convolutional neural networks (DCNN) have demonstrated its capability to convert MR image to pseudo CT for PET attenuation correction in PET/MRI. Conventionally, attenuated events are corrected in sinogram space using attenuation maps…

Computer Vision and Pattern Recognition · Computer Science 2019-05-22 Jaewon Yang , Dookun Park , Jae Ho Sohn , Zhen Jane Wang , Grant T. Gullberg , Youngho Seo

X-ray scatter remains a major physics challenge in volumetric computed tomography (CT), whose physical and statistical behaviors have been commonly leveraged in order to eliminate its impact on CT image quality. In this work, we conduct an…

Medical Physics · Physics 2021-03-05 Tao Zhang , Zhiqiang Chen , Hao Zhou , N. Robert Bennett , Adam S. Wang , Hewei Gao

Scatter signals can degrade the contrast and resolution of computed tomography (CT) images and induce artifacts. How to effectively correct scatter signals in CT has always been a focal point of research for researchers. This work presents…

Medical Physics · Physics 2025-01-10 Guiyuan Lin , Shiwo Deng , Xiaoqun Wang , Xing Zhao

Our interest has been to study the effect that scattered radiation has on contrast, signal-to-noise ratio and thickness reconstruction in digital mammographies. Using the GEANT code we have performed Monte-Carlo simulations of 25 kVp Mo/Mo…

Medical Physics · Physics 2009-09-29 Varlen Grabski , Maria-Ester Brandan

The single-scatter approximation is fundamental in many tomographic imaging problems including x-ray scatter imaging and optical scatter imaging for certain media. In all cases, noisy measurements are affected by both local scatter events…

Image and Video Processing · Electrical Eng. & Systems 2021-04-21 Michael R. Walker , Joseph A. O'Sullivan

A novel Positron Emission Tomography system, based on plastic scintillators, is being developed by the J-PET collaboration. In this article we present the simulation results of the scatter fraction, representing one of the parameters…

This paper provides a fast and patient-specific scatter artifact correction method for cone-beam computed tomography (CBCT) used in image-guided interventional procedures. Due to increased irradiated volume of interest in CBCT imaging,…

Medical Physics · Physics 2015-01-20 Wei Zhao , Stephen Brunner , Kai Niu , Sebastian Schafer , Kevin Royalty , Guang-Hong Chen

Multi-source stationary computed tomography (MSS-CT) offers significant advantages in medical and industrial applications due to its gantry-less scan architecture and/or capability of simultaneous multi-source emission. However, the lack of…

Medical Physics · Physics 2025-01-20 Yingxian Xia , Zhiqiang Chen , Li Zhang , Yuxiang Xing , Hewei Gao

In PET a high percentage of gamma photons being detected undergo Compton scattering in the scintillator. Scintillator blocks are often built from optically isolated crystals. Depending on the angle of incidence and the scintillator geometry…

Medical Physics · Physics 2023-11-01 Katrin Herweg , Volkmar Schulz , David Schug

Scatter due to interaction of photons with the imaged object is a fundamental problem in X-ray Computed Tomography (CT). It manifests as various artifacts in the reconstruction, making its abatement or correction critical for image quality.…

Medical Physics · Physics 2024-01-30 Berk Iskender , Yoram Bresler

As photon counting detectors are being explored for medical and industrial imaging applications, there is a critical need to understand spectral characteristics of scattered x-ray photons. Scattered radiation is detrimental to x-ray imaging…

Medical Physics · Physics 2022-12-14 Cale E. Lewis , Mini Das
‹ Prev 1 2 3 10 Next ›