English
Related papers

Related papers: PPORLD-EDNetLDCT: A Proximal Policy Optimization-B…

200 papers

Low-dose computed tomography (LDCT) reduces patient radiation exposure but introduces substantial noise that degrades image quality and hinders diagnostic accuracy. Existing denoising approaches often require many diffusion steps, limiting…

Medical Physics · Physics 2025-10-29 Qiang Li , Mojtaba Safari , Shansong Wang , Huiqiao Xie , Jie Ding , Tonghe Wang , Xiaofeng Yang

Low Dose Computed Tomography (LDCT) is clinically desirable due to the reduced radiation to patients. However, the quality of LDCT images is often sub-optimal because of the inevitable strong quantum noise. Inspired by their unprecedent…

Image and Video Processing · Electrical Eng. & Systems 2021-02-02 Ti Bai , Dan Nguyen , Biling Wang , Steve Jiang

Despite the indispensable role of X-ray computed tomography (CT) in diagnostic medicine field, the associated ionizing radiation is still a major concern considering that it may cause genetic and cancerous diseases. Decreasing the exposure…

Image and Video Processing · Electrical Eng. & Systems 2021-06-09 Ti Bai , Dan Nguyen , Biling Wang , Steve Jiang

Low-Dose computer tomography (LDCT) is an ideal alternative to reduce radiation risk in clinical applications. Although supervised-deep-learning-based reconstruction methods have demonstrated superior performance compared to conventional…

Image and Video Processing · Electrical Eng. & Systems 2024-05-24 Feng Wang , Renfang Wang , Hong Qiu

Low-dose computed tomography (LDCT) became a clear trend in radiology with an aspiration to refrain from delivering excessive X-ray radiation to the patients. The reduction of the radiation dose decreases the risks to the patients but…

Image and Video Processing · Electrical Eng. & Systems 2021-02-05 Elvira Zainulina , Alexey Chernyavskiy , Dmitry V. Dylov

Low-dose computed tomography (LDCT) offers significant advantages in reducing the potential harm to human bodies. However, reducing the X-ray dose in CT scanning often leads to severe noise and artifacts in the reconstructed images, which…

Image and Video Processing · Electrical Eng. & Systems 2024-08-27 Ran An , Yinghui Zhang , Xi Chen , Lemeng Li , Ke Chen , Hongwei Li

Low-dose Computed Tomography (LDCT) reconstruction is an important task in medical image analysis. Recent years have seen many deep learning based methods, proved to be effective in this area. However, these methods mostly follow a…

Image and Video Processing · Electrical Eng. & Systems 2023-02-08 Runyi Li

Computed Tomography (CT) is a vital diagnostic tool in clinical practice, yet the health risks associated with ionizing radiation cannot be overlooked. Low-dose CT (LDCT) helps mitigate radiation exposure but simultaneously leads to reduced…

Computer Vision and Pattern Recognition · Computer Science 2025-11-20 Guoliang Gong , Man Yu

The resurgence of deep neural networks has created an alternative pathway for low-dose computed tomography denoising by learning a nonlinear transformation function between low-dose CT (LDCT) and normal-dose CT (NDCT) image pairs. However,…

Image and Video Processing · Electrical Eng. & Systems 2022-11-04 Sutanu Bera , Prabir Kumar Biswas

Image denoising of low-dose computed tomography (LDCT) is an important problem for clinical diagnosis with reduced radiation exposure. Previous methods are mostly trained with pairs of synthetic or misaligned LDCT and normal-dose CT (NDCT)…

Image and Video Processing · Electrical Eng. & Systems 2025-02-04 Junhao Long , Fengwei Yang , Juncheng Yan , Baoping Zhang , Chao Jin , Jian Yang , Changliang Zou , Jun Xu

Deep learning is a very promising technique for low-dose computed tomography (LDCT) image denoising. However, traditional deep learning methods require paired noisy and clean datasets, which are often difficult to obtain. This paper…

Image and Video Processing · Electrical Eng. & Systems 2023-08-15 Yuting Zhu , Qiang He , Yudong Yao , Yueyang Teng

Low-dose computed tomography (LDCT) aims to minimize the radiation exposure to patients while maintaining diagnostic image quality. However, traditional CT reconstruction algorithms often struggle with the ill-posed nature of the problem,…

Image and Video Processing · Electrical Eng. & Systems 2024-10-17 Daisy Chen

In clinical examinations and diagnoses, low-dose computed tomography (LDCT) is crucial for minimizing health risks compared with normal-dose computed tomography (NDCT). However, reducing the radiation dose compromises the signal-to-noise…

Image and Video Processing · Electrical Eng. & Systems 2024-07-02 Haoyu Zhao , Yuliang Gu , Zhou Zhao , Bo Du , Yongchao Xu , Rui Yu

Low-dose computed tomography (LDCT) is an important topic in the field of radiology over the past decades. LDCT reduces ionizing radiation-induced patient health risks but it also results in a low signal-to-noise ratio (SNR) and a potential…

Image and Video Processing · Electrical Eng. & Systems 2022-10-03 Wenjun Xia , Qing Lyu , Ge Wang

Recently, Self-supervised learning methods able to perform image denoising without ground truth labels have been proposed. These methods create low-quality images by adding random or Gaussian noise to images and then train a model for…

Image and Video Processing · Electrical Eng. & Systems 2021-04-07 Dongkyu Won , Euijin Jung , Sion An , Philip Chikontwe , Sang Hyun Park

The use of deep learning has successfully solved several problems in the field of medical imaging. Deep learning has been applied to the CT denoising problem successfully. However, the use of deep learning requires large amounts of data to…

Image and Video Processing · Electrical Eng. & Systems 2022-04-04 Mayank Patwari , Ralf Gutjahr , Rainer Raupach , Andreas Maier

Low Dose Computed Tomography (LDCT) has offered tremendous benefits in radiation restricted applications, but the quantum noise as resulted by the insufficient number of photons could potentially harm the diagnostic performance. Current…

Computer Vision and Pattern Recognition · Computer Science 2019-03-06 Xin Yi , Paul Babyn

Low-dose computed tomography (LDCT) is the standard modality for lung cancer screening, known for its low radiation dose but high noise levels. While existing literature focuses on denoising LDCT images, comparative research on simulating…

Image and Video Processing · Electrical Eng. & Systems 2026-05-13 Jiaying Liu , Anna Corti , Valentina D. A. Corino , Luca Mainardi

Low-dose CT (LDCT) reduces radiation exposure but introduces protocol-dependent noise and artifacts that vary across institutions. While federated learning enables collaborative training without centralizing patient data, existing methods…

Image and Video Processing · Electrical Eng. & Systems 2026-03-17 Anas Zafar , Muhammad Waqas , Amgad Muneer , Rukhmini Bandyopadhyay , Jia Wu

Low-dose CT (LDCT) imaging is desirable in many clinical applications to reduce X-ray radiation dose to patients. Inspired by deep learning (DL), a recent promising direction of model-based iterative reconstruction (MBIR) methods for LDCT…

Image and Video Processing · Electrical Eng. & Systems 2021-02-18 Qiaoqiao Ding , Yuesong Nan , Hao Gao , Hui Ji
‹ Prev 1 2 3 10 Next ›