Although the so-called magnetic geometrical factor, $Bl$, of a Kibble balance does not appear in the Kibble equations, it offers the precision link between electrical and mechanical quantities and furthers a quasi-quantum traceability path…

Instrumentation and Detectors · Physics 2024-09-06 Yongchao Ma , Nanjia Li , Weibo Liu , Kang Ma , Wei Zhao , Songling Huang , Shisong Li

The Kibble balance is a precision instrument for realizing the mass unit, the kilogram, in the new international system of units (SI). In recent years, an important trend for Kibble balance experiments is to go tabletop, in which the…

Instrumentation and Detectors · Physics 2023-04-24 Shisong Li , Yongchao Ma , Wei Zhao , Songling Huang , Xinjie Yu

With the adoption of the revised International System of Units (SI), the Kibble balance has become a pivotal instrument for mass calibrations against the Planck constant, $h$. One of the major focuses in the Kibble balance community is…

Instrumentation and Detectors · Physics 2024-12-18 Shisong Li , Yongchao Ma , Kang Ma , Weibo Liu , Nanjia Li , Xiaohu Liu , Lisha Peng , Wei Zhao , Songling Huang , Xinjie Yu

The magnet system is an essential component of the Kibble balance, a device that is used to realize the unit of mass. It is the source of the magnetic flux, and its importance is captured in the geometric factor $Bl$. Ironically, the $Bl$…

Instrumentation and Detectors · Physics 2022-03-14 Shisong Li , Stephan Schlamminger

Yoke-based permanent magnetic circuits are widely used in Kibble balance experiments. In these magnetic systems, the coil current, with positive and negative signs in two steps of the weighing measurement, can cause an additional magnetic…

Instrumentation and Detectors · Physics 2019-12-18 Shisong Li , Franck Bielsa , Michael Stock , Adrien Kiss , Hao Fang

Tabletop version Kibble balances are a significant developing trend for mass realizations following the revised International System of Units. A key innovation through the miniaturization of the Kibble balance from a large-scale instrument…

Instrumentation and Detectors · Physics 2026-01-27 Shisong Li , Nanjia Li , Weibo Liu , Elsayed E. E. Qupasie , Wei Zhao , Songling Huang

The Kibble balance realizes the kilogram by linking mechanical and electrical quantities via a magnet system. In an improved BIPM-type magnet design by Tsinghua University, an open/close surface was incorporated, facilitating operation.…

Instrumentation and Detectors · Physics 2025-10-07 Nanjia Li , Weibo Liu , Yongchao Ma , Wei Zhao , Songling Huang , Shisong Li

Permanent magnets together with yokes to concentrate the magnetic flux into a cylindrical air-gap are widely employed in Kibble balances. These experiments require a uniform magnetic flux density along a vertical path, typically a…

Instrumentation and Detectors · Physics 2020-03-10 Shisong Li , Stephan Schlamminger , Qing Wang

We studied the anelastic aftereffect of a flexure being used in a Kibble balance, where the flexure is subjected to a large excursion in velocity mode after which a high-precision force comparison is performed. We investigated the effect of…

Classical Physics · Physics 2024-10-03 Lorenz Keck , Stephan Schlamminger , René Theska , Frank Seifert , Darine Haddad

The Kibble balance has become one of the major instruments for realizing the mass unit, the kilogram, in the revised international system of units (SI). Researchers at about a dozen national metrology institutes are actively working with…

Instrumentation and Detectors · Physics 2022-06-09 Shisong Li , Stephan Schlamminger

This paper presents a novel seven-channel optical measurement system for monitoring coil parasitic motion and mass position in the Tsinghua Tabletop Kibble balance. The system employs seven spectrally-confocal displacement sensors arranged…

Instrumentation and Detectors · Physics 2026-05-19 Weibo Liu , Kang Ma , Nanjia Li , Wei Zhao , Songling Huang , Shisong Li

This paper presents recent advances in the KBmini Kibble balance, a tabletop system for E2-accuracy mass calibration up to 1 kg. The $Bl(z)$ profile is characterized by manually setting the magnet at different vertical positions, and the…

Instrumentation and Detectors · Physics 2026-05-07 Nanjia Li , Weibo Liu , Kang Ma , Elsayed E. E. Qupasie , Wei Zhao , Songling Huang , Shisong Li

A high-precision current source, capable of supporting weighing measurements with a relative uncertainty at the $10^{-9}$ level, is essential for Kibble balance experiments. However, most current sources utilized in Kibble balances to date…

Instrumentation and Detectors · Physics 2024-08-30 Kang Ma , Xiaohu Liu , Wei Zhao , Songling Huang , Shisong Li

The design of the permanent magnet system for the new Quantum Electro-Mechanical Metrology Suite (QEMMS) is described. The QEMMS, developed at the National Institute of Standards and Technology (NIST), consists of a Kibble balance, a…

Instrumentation and Detectors · Physics 2019-12-30 Rafael R. Marangoni , Darine Haddad , Frank Seifert , Leon S. Chao , David B. Newell , Stephan Schlamminger

We consider the application of the magnetic flux leakage (MFL) method to the detection of defects in ferromagnetic (steel) tubulars. The problem setup corresponds to the cases where the distance from the casing and the point where the…

Data Analysis, Statistics and Probability · Physics 2015-11-10 Anastasiya V. Pimenova , Denis S. Goldobin , Jeremy Levesley , Andrey O. Ivantsov , Peter Elkington , Mark Bacciarelli

This study numerically evaluates the external magnetic flux density generated in air by the bending of a piezo-flexomagnetic nanobeam. In several classes of non-contact sensors, the magnetic field induced in the surrounding medium is often…

Materials Science · Physics 2026-05-20 Lala Samprit Ray , Bishweshwar Babu

Watt balances are used to measure the Planck constant and will be used in the future to realize mass at the kilogram level. They increasingly rely on permanent magnet systems to generate the magnetic flux. It has been known that the…

Classical Physics · Physics 2014-07-22 Shisong Li , Stephan Schlamminger , Jon Pratt

A yoke-based permanent magnet, which has been employed in many watt balances at national metrology institutes, is supposed to generate strong and uniform magnetic field in an air gap in the radial direction. However, in reality the fringe…

Instrumentation and Detectors · Physics 2016-03-23 Zhuang Fu , Zhonghua Zhang , Zhengkun Li , Wei Zhao , Bing Han , Yunfeng Lu , Shisong Li

The precision of the values of a magnetic field generated by electromagnetic flux compression was investigated in ultra-high magnetic fields of up to 700 T. In an attempt to calibrate the magnetic field measured by pickup coils, precise…

Instrumentation and Detectors · Physics 2013-09-05 D. Nakamura , H. Sawabe , Y. H. Matsuda , S. Takeyama

Analytically the forces and torques on a coil in a field of magnetic flux density can be calculated one of two ways. The line integral can be conducted along the coil's wire, summing up the differential force contribution. For each…

Instrumentation and Detectors · Physics 2022-09-20 Stephan Schlamminger , Lorenz Keck , Frank Seifert , Leon S. Chao , Darine Haddad , Shisong Li