Related papers: Development and testing of integrated readout elec…
We present a detailed characterization of a new generation of athermal-phonon single-charge sensitive Si HVeV detectors, the best of which achieved 612 meV $\pm$ 4 meV baseline resolution. Our sub-eV energy resolution enables precise…
A new TDC-chip is under development for the COMPASS experiment at CERN. The ASIC, which exploits the 0.6 micrometer CMOS sea-of-gate technology, will allow high resolution time measurements with digitization of 75 ps, and an unprecedented…
A crucial requirement for quantum computing, in particular for scalable quantum computing and error correction, is a fast and high-fidelity qubit readout. For semiconductor based qubits, one limiting factor for local low-power signal…
We demonstrate first experimental investigation on the performance of a single-node reservoir computer based on a silicon microring resonator (MRR) operating on the digit recognition task. The input layer of the reservoir is composed of a…
In Charge Coupled Device (CCD) detectors the electrons excited upon absorption of a single x-ray photon quickly diffuse and generate charge-spots often larger than pixel dimensions. In the soft x-ray range this phenomenon drastically limits…
CONCERTO is a millimeter-wave imaging instrument that operated on the Atacama Pathfinder Experiment (APEX) telescope from April 2021 to May 2023. Its primary scientific objectives include the study of galaxy clusters through the…
The CLARO-CMOS is an application specific integrated circuit (ASIC) designed for fast photon counting with pixellated photodetectors such as multi-anode photomultiplier tubes (Ma-PMT), micro-channel plates (MCP), and silicon…
The upgrade of the Resistive Plate Chamber (RPC) detector, in order to increase the detector rate capability and to be able to work efficiently in high rate environment, consists in the reduction of the operating voltage along with the…
Speech enhancement and separation have been a long-standing problem, especially with the recent advances using a single microphone. Although microphones perform well in constrained settings, their performance for speech separation decreases…
This paper presents a low noise amplifier for large arrays of silicon photomultipliers (SiPMs) operated in cryogenic environments, especially liquid argon (87 K) and liquid nitrogen (77 K). The goal is for one amplifier to read out a total…
Hybrid silicon pixel detectors are currently used in the innermost tracking system of the Compact Muon Solenoid (CMS) experiment. Radiation tolerance up to fluences expected for a few years of running of the Large Hadron Collider (LHC) has…
We present the development of a single-photon detector and the connected read-out electronics. This `hybrid' detector is based on a vacuum tube, transmission photocathode, microchannel plate and a pixelated CMOS read-out anode encapsulating…
MiniCACTUS is a monolithic sensor prototype optimised for timing measurement of charged particles. It has been designed in a standard 150 nm CMOS process without dedicated amplification layer. It is intended as a demonstrator chip for…
This paper presents experimental results that allow for the performance evaluation of a straight-line reference alignment system based on pseudo-nondiffracting Layer beams. Sensors, developed specifically for this system, feature four…
Spins in semiconductor quantum dots hold great promise as building blocks of quantum processors. Trapping them in SiMOS transistor-like devices eases future industrial scale fabrication. Among the potentially scalable readout solutions,…
A voltage amplifier, based on the BFU500XRR NPN transistor in a common-emitter configuration, was developed for the readout of the fast output of an ONSEMI MicroFC-10035 Silicon Photomultiplier (SiPM). This amplifier was tested and…
This paper presents a first study of the performance of a novel 2D position-sensitive microstrip detector, where the resistive charge division method was implemented by replacing the metallic electrodes with resistive electrodes made of…
The sensitivity of next-generation gravitational-wave detectors such as Advanced LIGO and LCGT should be limited mostly by quantum noise with an expected technical progress to reduce seismic noise and thermal noise. Those detectors will…
Charge Coupled Devices (CCDs) have been successfully used in several high energy physics experiments over the past two decades. Their high spatial resolution and thin sensitive layers make them an excellent tool for studying short-lived…
This paper presents a millimeter-scale CMOS 64$\times$64 single charged particle radiation detector system for external beam cancer radiotherapy. A 1$\times$1 $\mu m^2$ diode measures energy deposition by a single charged particle in the…