English
Related papers

Related papers: $\beta$-Ga$_2$O$_3$--Based Radiation Detector for …

200 papers

We report a design and implementation of proton radiography with an in situ reference X-ray image of a mesh to precisely measure non-uniform magnetic fields in expanding plasmas at the OMEGA and OMEGA EP laser facilities. The technique has…

Plasma Physics · Physics 2022-02-23 S. Malko , C. Johnson , D. B. Schaeffer , W. Fox , G. Fiksel

Medical synchrotrons are often used for testing instrumentation in high-energy physics or non-clinical research in medical physics. In many applications of medical synchrotrons, such as microdosimetry and ion imaging, precise knowledge of…

Two major challenges in time-of-flight positron emission tomography (TOF-PET) are low spatial resolution and high radioactive dose to the patient, both of which result from limitations in detection technology rather than fundamental…

The HICAT project is a Heavy Ion accelerator for light ion Cancer Treatment to be built for the clinics in Heidelberg, Germany. It consists of a 7 MeV/u linac, a compact synchrotron and three treatment places, one of them equipped with a…

Accelerator Physics · Physics 2007-05-23 Ralph C. Baer , Hartmut Eickhoff , Thomas Haberer

Organic photodetectors (OPDs) possess bright prospects in applications of medical imaging and wearable electronics due to the advantages such as low cost, good biocompatibility, and good flexibility. Photomultiplication OPDs (PM-OPDs)…

The background induced by the high penetration power of the gamma radiation is the main limiting factor of the current Radio-guided surgery (RGS). To partially mitigate it, a RGS with beta+ emitting radio-tracers has been suggested in…

Advanced radiotherapy approaches such as FLASH irradiation and spatially fractionated radiotherapy (SFRT) show potential to improve the therapeutic ratio, yet their biological mechanisms and optimal delivery parameters remain uncertain.…

Epitaxial thin films of La0.7Ba0.3MnO3 manganite, deposited using Chemical Solution Deposition technique, were irradiated by 200 MeV Ag+15 ions with a maximum ion dose up to 1x10^12 ions/cm2. Temperature- and magnetic field-dependent…

Materials Science · Physics 2009-11-11 R. N. Parmar , J. H. Markna , D. G. Kuberkar , Ravi Kumar , D. S. Rana , Vivas C. Bagve , S. K. Malik

Positron decays of proton-rich nuclides exhibit large $Q$ values, producing complex cascades which often involve various radiations, including protons and $\gamma$ rays. Often, only one of the two are measured in a single experiment,…

One of the possible ways to maintain the micrometer spatial resolution while performing ion beam analysis in the air is to increase the energy of ions. In order to explore capabilities and limitations of this approach, we have tested a…

Instrumentation and Detectors · Physics 2019-03-13 Milko Jakšić , Davit Chokheli , Stjepko Fazinić , Veljko Grilj , Natko Skukan , Ivan Sudić , Tonči Tadić , Tome Antičić

Hadrontherapy is a novel technique of cancer radiation therapy which employs beams of charged hadrons, protons and carbon ions in particular. Due to their physical and radiobiological properties, they allow one to obtain a more conformal…

Medical Physics · Physics 2015-05-14 Saverio Braccini

Uncertainties in the proton range in tissue during proton therapy limit the precision in treatment delivery. These uncertainties result in expanded treatment margins, thereby increasing radiation dose to healthy tissue. Real-time range…

Medical Physics · Physics 2018-10-17 Kristian Smeland Ytre-Hauge , Kyrre Skjerdal , John Mattingly , Ilker Meric

In the last two decades, the generation of intense ion beams based on laser-driven sources has become an extensively investigated field. The LIGHT collaboration combines a laserdriven intense ion source with conventional accelerator…

Accelerator Physics · Physics 2018-12-26 D. Jahn , D. Schumacher , C. Brabetz , J. Ding , S. Weih , F. Kroll , F. -E. Brack , U. Schramm , A. Blazevic , M. Roth

The Integrable Optics Test Accelerator (IOTA) is a storage ring for advanced beam physics research currently being built and commissioned at Fermilab. It will operate with protons and electrons using injectors with momenta of 70 and 150…

We recently proposed a new approach for the real-time monitoring of particle therapy treatments with the goal of achieving high sensitivities on the particle range measurement already at limited counting statistics. This method extends the…

A liquid isooctane (C$_{8}$H$_{18}$) filled ionization linear array for radiotherapy quality assurance has been designed, built and tested. The detector consists of 128 pixels, each of them with an area of 1.7 mm $\times$ 1.7 mm and a gap…

Medical Physics · Physics 2009-11-10 J. Pardo , L. Franco , F. Gomez , A. Iglesias , A. Pazos , J. Pena , R. Lobato , J. Mosquera , M. Pombar , J. Sendon

Stereotactic body radiation therapy (SBRT) and hypofractionation using pencil-beam scanning (PBS) proton therapy (PBSPT) is an attractive option for thoracic malignancies. Combining the advantages of target coverage conformity and critical…

Radiation therapy with protons as of today utilizes information from x-ray CT in order to estimate the proton stopping power of the traversed tissue in a patient. The conversion from x-ray attenuation to proton stopping power in tissue…

The TITAN facility at TRIUMF has recently initiated a program of performing decay spectroscopy measurements in an electron-beam ion-trap (EBIT). The unique environment of the EBIT provides backing-free storage of the radioactive ions, while…

Instrumentation and Detectors · Physics 2015-07-01 K. G. Leach , A. Lennarz , A. Grossheim , C. Andreoiu , J. Dilling , D. Frekers , M. Good , S. Seeraji