English
Related papers

Related papers: $\beta$-Ga$_2$O$_3$--Based Radiation Detector for …

200 papers

Intensity-modulated proton therapy (IMPT) employs proton radiation rather than conventional X-rays to treat cancerous tumors. This approach offers significant advantages by minimizing the radiation exposure of surrounding healthy tissue,…

Background: Intensity-modulated proton therapy (IMPT) using pencil beam technique scans tumor in a layer by layer, then spot by spot manner. It can provide highly conformal dose to tumor targets and spare nearby organs-at-risk (OAR). Fast…

Medical Physics · Physics 2024-11-28 Aoxiang Wang , Ya-Nan Zhu , Jufri Setianegara , Yuting Lin , Peng Xiao , Qingguo Xie , Hao Gao

Intensity modulated proton therapy (IMPT) provides highly conformal dose distributions through the application of multiple, angularly spaced fields, each applying an ad-hoc pattern of spatially varying particle fluences. In particular,…

Medical Physics · Physics 2017-03-10 F. Arcadu

We developed a novel method of creating intensity modulated proton arc therapy (IMPAT) plans that uses computing resources efficiently and may offer a dosimetric benefit for patients with ependymoma or similar tumor geometries. Our IMPAT…

Ion beam therapy has become a frequently applied form of cancer therapy over the last years. The advantage of ion beam therapy over conventional radiotherapy using photons is the strongly localized dose deposition, leading to a reduction of…

Instrumentation and Detectors · Physics 2020-07-28 F. Ulrich-Pur , T. Bergauer , A. Burker , S. Hatamikia , A. Hirtl , C. Irmler , S. Kaser , P. Paulitsch , F. Pitters , V. Teufelhart

Charged particle therapy (CPT) is an advanced modality of radiation therapy which has grown rapidly worldwide, driven by recent developments in technology and methods of delivery. To ensure safe and high quality treatments, various…

Instrumentation and Detectors · Physics 2021-11-16 J. S. L. Yap , N. J. S. Bal , A. Kacperek , J. Resta López , C. P. Welsch

Purpose: Intensity-modulated proton therapy (IMPT) offers precise tumor coverage while sparing organs at risk (OARs) in head and neck (H&N) cancer. However, its sensitivity to anatomical changes requires frequent adaptation through online…

Background and purpose: IMPT faces challenges in lung cancer treatment, like maintaining plan robustness for moving tumors against setup, range errors, and interplay effects. Proton Arc Therapy (PAT) is an alternative to maintain target…

Intensity-modulated proton therapy (IMPT) offers superior dose conformity with reduced exposure to surrounding healthy tissues compared to conventional photon therapy. Improving IMPT delivery efficiency reduces motion-related uncertainties,…

Medical Physics · Physics 2025-04-15 Ya-Nan Zhu , Nimita Shinde , Bowen Lin , Hao Gao

The TOP-IMPLART project consists of the design and implementation of a linear proton accelerator, its control and monitoring systems for the treatment of superficial and semi-deep tumors. The energy of 150 MeV (corresponding to a…

We summarize recent results and ongoing activities in mathematical algorithms and computer science methods related to proton computed tomography (pCT) and intensity-modulated particle therapy (IMPT) treatment planning. Proton therapy…

Medical Physics · Physics 2021-08-24 Yair Censor , Keith E. Schubert , Reinhard W. Schulte

Proton therapy is a cancer treatment technique currently in growth worldwide. It offers advantages with respect to conventional X-ray and $\gamma$-ray radiotherapy, in particular, a better control of the dose deposition allowing to reach a…

Prompt Gamma Timing (PGT) is a promising technique for in vivo range verification in particle therapy, exploiting the time-of-flight between primary particles and prompt gamma rays emitted by nuclear interactions. PGT distribution is highly…

Every radiotherapy center has to be equipped with real-time beam monitoring devices. In 2008, the medical application group from the Laboratory of Corpuscular Physics (LPC Caen) developed an Ionization Chamber in collaboration with the…

Instrumentation and Detectors · Physics 2015-06-16 C. Courtois , G. Boissonnat , C. Brusasco , J. Colin , D. Cussol , J. M. Fontbonne , B. Marchand , T. Mertens , S. De Neuter , J. Perronnel

Objective: Proton spot-scanning arc therapy (ARC) is an emerging modality that can improve the high-dose conformity to targets compared with standard intensity-modulated proton therapy (IMPT). However, the efficient treatment delivery of…

We developed a novel gamma-ray detection system (TIARA) for range monitoring in Particle Therapy. The system employs Cherenkov-based gamma-ray detection modules arranged around the target or patient, operated in time coincidence with a fast…

Proton therapy's full potential is limited by uncertainties that prevent optimal dose distribution. Monitoring techniques can reduce these uncertainties and enable adaptive treatment planning. Spatiotemporal Emission Reconstruction from…

We have been developing the SOI pixel detector ``INTPIX'' for space use and general purpose applications such as the residual stress measurement of a rail and high energy physics experiments. INTPIX is a monolithic pixel detector composed…

Purpose:The recently proposed IPO-IMPT framework allows simultaneous optimization of dose, dose rate, and LET for FLASH treatment planning. Finding solutions to IPO-IMPT is difficult due to computational intensiveness. Nevertheless, an…

Enhanced-accuracy ion-range verification in real time shall enable a significant step forward in the use of therapeutic ion beams. Positron-emission tomography (PET) and prompt-gamma imaging (PGI) are two of the most promising and…

‹ Prev 1 2 3 10 Next ›