Related papers: Shaping circuit for improving linearity, bandwidth…
A high-precision charge measurement can be achieved by the area integration of a digitized quasi-Gaussian signal after the signal passes through the shaper and analog-to-digital converter (ADC). The charge measurement contains an error due…
Time-domain sampling of arbitrary electric fields with sub-cycle resolution enables a complete time-frequency analysis of a system's response to electromagnetic illumination. This provides access to dynamic information that is not provided…
We present a tensor-network-based method for simulating a weakly-measured quantum circuit. In particular, we use a Markov chain to efficiently sample measurements and contract the tensor network, propagating their effect forward along the…
Accurate and efficient circuit behavior modeling is a cornerstone of modern electronic design automation. Among different types of circuits, stiff circuits are challenging to model using previous frameworks. In this work, we propose a new…
A high accuracy and high sensitivity system architecture is proposed for the read-out circuit of electrical impedance tomography system-on-chip. The switched ratiometric technique is applied in the proposed architecture. The proposed system…
Transition-edge sensors (TESs) are capable of highly accurate single particle energy measurement. TESs have been used for a wide range of photon detection applications, particularly in astronomy, but very little consideration has been given…
Timing systems based on Analog-to-Digital Converters are widely used in the design of previous high energy physics detectors. In this paper, we propose a new method based on deep learning to extract the time information from a finite set of…
We present a (proto) Foundation Model for Nuclear Physics, capable of operating on low-level detector inputs from Imaging Cherenkov Detectors at the future Electron Ion Collider. Building upon established next-token prediction approaches,…
This paper will discuss a new method of signal read-out from photon detectors in ultra-large, underground liquid argon time projection chambers. In this design, the signal from the light collection system is coupled via capacitive plates to…
The baseline energy-resolution performance for the current generation of large-mass, low-temperature calorimeters (utilizing TES and NTD sensor technologies) is $>2$ orders of magnitude worse than theoretical predictions. A detailed study…
The next generation of ultra-low-noise cryogenic detectors for space science applications require continued exploration of materials characteristics at low temperatures. The low noise and good energy sensitivity of current Transition Edge…
Development of readout electronics for Time Projection Chamber for a Linear Collider is ongoing under stringent requirements on high channel density, lowest possible power consumption and small material budget. In the studied TPC readout…
A laser calibration system was developed for monitoring and calibrating time of flight (TOF) scintillating detector arrays. The system includes setups for both small- and large-scale scintillator arrays. Following test-bench…
We present a new technology for the shaping of the electric field in Time Projection Chambers (TPCs) using a carbon-loaded polyimide foil. This technology allows for the minimisation of passive material near the active volume of the TPC and…
Cadmium zinc telluride (CdZnTe, CZT) radiation detectors are suitable for a variety of applications, due to their high spatial resolution and spectroscopic energy performance at room temperature. However, state-of-the-art detector systems…
The Large High Altitude Air Shower Observatory is in the R&D phase, in which the Water Cherenkov Detector Array is an important part. The signals of Photo-Multiplier Tubes would vary from single photo electron to 4000 photo electrons, and…
Nowadays, in Positron Emission Tomography (PET) systems, a Time of Flight information is used to improve the image reconstruction process. In Time of Flight PET (TOF-PET), fast detectors are able to measure the difference in the arrival…
Recent advances in machine learning have opened new avenues for optimizing detector designs in high-energy physics, where the complex interplay of geometry, materials, and physics processes has traditionally posed a significant challenge.…
Transition Radiation (TR) plays an important role in particle identification in high-energy physics and its characteristics provide a feasible method of energy calibration in the energy range up to 10 TeV, which is of interest for dark…
Wearable electrocardiograph (ECG) recording and processing systems have been developed to detect cardiac arrhythmia to help prevent heart attacks. Conventional wearable systems, however, suffer from high energy consumption at both circuit…