Related papers: Aluminium fast neutron leakage spectrum validation
The nuGeN experiment searches for coherent elastic neutrino-nucleus scattering (CEvNS) at the Kalinin Nuclear Power Plant. A 1.41-kg high-purity low-threshold germanium detector surrounded by active and passive shielding is deployed at the…
The proposed high flux lithium antineutrino source is based on 7Li(n,g)8Li-activation and subsequent fast beta-decay (0.84 s) of the 8Li isotope with emission of hard antineutrinos with energy up to 13 MeV. In the discussed scheme the…
In the work presented here we built and evaluated a single-channel neutron detection unit consisting of a ZnS:$^6$LiF scintillator with embedded WLS fibers readout by a SiPM. The unit has a sensitive volume of 2.4 x 2.8 x 50 mm$^3$; 12 WLS…
A time-of-flight spectrometer of neutrons in the energy range (0.05 -- 2.5)$\mu$eV is described. This spectrometer has been tested my measuring the total and differential neutron cross sections for a number of materials: Al, Cu, $^{6}$LiF,…
We investigate scintillation linearity of a commercial high pressure $^4$He gas detector using monoenergetic 2.8 MeV neutrons from a deuterium-deuterium fusion neutron generator. The scintillation response of the detector was measured for a…
Following the completion of the second neutron beam line and the related experimental area (EAR2) at the n_TOF spallation neutron source at CERN, several experiments were planned and performed. The high instantaneous neutron flux available…
We report on the neutron response of the LAMBDA spectrometer developed earlier for high-energy gamma-ray measurement. The energy dependent neutron detection efficiency of the spectrometer has been measured using the time-of-flight (TOF)…
The work is devoted to development of hard electron antineutrino source with variable and regulated (controlled) spectrum. The high flux antineutrino source with hard antineutrino spectrum based on neutron activation of 7Li and subsequent…
With the advent of detectors with sub-keV sensitivities, atomic ionization has been identified as a promising avenue to probe possible neutrino electromagnetic properties. The interaction cross-sections induced by millicharged neutrinos are…
We report on the development of a fast neutron detector using a liquid scintillator doped with enriched Li-6. The lithium was introduced in the form of an aqueous LiCl micro-emulsion with a di-isopropylnaphthalene-based liquid scintillator.…
Systematics have been created for neutron spectra from the 7Li(p,n) reaction at 0 deg in the 50-200 MeV proton energy region. The available experimental data in the continuum part of the spectra show satisfactory overall agreement with a…
In an antiproton production (Pbar) target station of the Fermi National Accelerator Laboratory (FNAL), the secondary particles produced by bombarding a target with 120-GeV protons are shielded by a thick iron shield. In order to obtain…
We present the first measurements of the muon-induced neutron flux at the Boulby Underground Laboratory. The experiment was carried out with an 0.73 tonne liquid scintillator that also served as an anticoincidence system for the ZEPLIN-II…
During 2014 the second experimental area EAR2 was completed at the n-TOF neutron beam facility at CERN. As the neutrons are produced via spallation, by means of a high-intensity 20 GeV pulsed proton beam impinging on a thick target, the…
Dark matter detectors require calibrations of their energy scale and efficiency to detect nuclear recoils in the $1-50$ keV range. Most calibrations use neutron scattering and require MCNP or Geant4 simulations of neutron propagation…
The total bremsstrahlung flux-averaged cross-sections <$\sigma$(E$_{{\gamma}max}$)> for the photonuclear reactions $^{nat}$Ni($\gamma$,xn)$^{57}$Ni and $^{nat}$Ni($\gamma$,xn)$^{56}$Ni have been measured in the range of end-point energies…
The RENO experiment reports measured flux and energy spectrum of reactor electron antineutrinos\,($\overline{\nu}_e$) from the six reactors at Hanbit Nuclear Power Plant. The measurements use 966\,094\,(116\,111)\,$\overline{\nu}_e$…
One of the main sources of a background in underground physics experiments (such as the investigation of solar neutrino flux, neutrino oscillations, neutrinoless double beta decay, and the search for annual and daily Cold Dark Matter…
Results of measured threshold activation reaction rates in 12C, 19F, 27Al, 59Co, 63Cu, 65Cu, 64Zn, 93Nb, 115In, 169Tm, 181Ta, 197Au, and 209Bi experimental samples placed both along the axis inside and outside a 0.8 GeV proton-irradiated…
In neutron transmutation doped germanium, the thermal neutron fluence of reactor irradiation is as high as 10$^{18}$~n$\cdot$cm$^{-2}$. For radiological safety reasons, general Co or Au neutron flux monitors cannot be easily used. We have…