Related papers: Functional Multi-Reference Alignment via Deconvolu…
We consider the problem of estimating a signal from noisy circularly-translated versions of itself, called multireference alignment (MRA). One natural approach to MRA could be to estimate the shifts of the observations first, and infer the…
Multireference alignment (MRA) is the problem of estimating a signal from many noisy and cyclically shifted copies of itself. In this paper, we consider an extension called heterogeneous MRA, where $K$ signals must be estimated, and each…
The multi-reference alignment (MRA) problem involves reconstructing a signal from multiple noisy observations, each transformed by a random group element. In this paper, we focus on the group \(\mathrm{SO}(2)\) of in-plane rotations and…
Multireference alignment (MRA) refers to the problem of recovering a signal from noisy samples subject to random circular shifts. Expectation--maximization (EM) and variational approaches use statistical modeling to achieve high accuracy at…
Motivated by structural biology applications, we study the projected multi-reference alignment (MRA) model, in which an unknown signal is observed through noisy samples, each generated by applying a random cyclic shift followed by a fixed…
Motivated by modern data applications such as cryo-electron microscopy, the goal of classic multi-reference alignment (MRA) is to recover an unknown signal $f: \mathbb{R} \to \mathbb{R}$ from many observations that have been randomly…
Multireference alignment (MRA) problem is to estimate an underlying signal from a large number of noisy circularly-shifted observations. The existing methods are always proposed under the hypothesis of a single Gaussian noise. However, the…
Motivated by single-particle cryo-electron microscopy, multi-reference alignment (MRA) models the task of recovering an unknown signal from multiple noisy observations corrupted by random rotations. The standard approach,…
From molecular imaging to wireless communications, the ability to align and reconstruct signals from multiple misaligned observations is crucial for system performance. We study the problem of multi-reference alignment (MRA), which arises…
The multi-reference alignment (MRA) problem entails estimating an image from multiple noisy and rotated copies of itself. If the noise level is low, one can reconstruct the image by estimating the missing rotations, aligning the images, and…
Motivated by cutting-edge applications like cryo-electron microscopy (cryo-EM), the Multi-Reference Alignment (MRA) model entails the learning of an unknown signal from repeated measurements of its images under the latent action of a group…
We study the 2-D super-resolution multi-reference alignment (SR-MRA) problem: estimating an image from its down-sampled, circularly-translated, and noisy copies. The SR-MRA problem serves as a mathematical abstraction of the structure…
This paper studies the application of the generalized method of moments (GMM) to multi-reference alignment (MRA): the problem of estimating a signal from its circularly-translated and noisy copies. We begin by proving that the GMM estimator…
We study super-resolution multi-reference alignment, the problem of estimating a signal from many circularly shifted, down-sampled, and noisy observations. We focus on the low SNR regime, and show that a signal in $\mathbb{R}^M$ is uniquely…
Rotation averaging (RA) is a fundamental problem in robotics and computer vision. In RA, the goal is to estimate a set of $N$ unknown orientations $R_{1}, ..., R_{N} \in SO(3)$, given noisy measurements $R_{ij} \sim R^{-1}_{i} R_{j}$ of a…
The growing role of data-driven approaches to scientific discovery has unveiled a large class of models that involve latent transformations with a rigid algebraic constraint. Three-dimensional molecule reconstruction in Cryo-Electron…
Motivated by the problem of determining the atomic structure of macromolecules using single-particle cryo-electron microscopy (cryo-EM), we study the sample and computational complexities of the sparse multi-reference alignment (MRA) model:…
Functional Magnetic Resonance Imaging (fMRI) is a neuroimaging technique with pivotal importance due to its scientific and clinical applications. As with any widely used imaging modality, there is a need to ensure the quality of the same,…
We study the multi-reference alignment (MRA) problem of recovering a signal from noisy observations acted on by unknown random circular shifts. While the information-theoretic limits of MRA are well characterized in many settings, the…
Faraday Rotation Measure (RM) synthesis requires the recovery of the Faraday Dispersion Function (FDF) from measurements restricted to limited wavelength ranges, which is an ill-conditioned deconvolution problem. Here, we propose a novel…