English
Related papers

Related papers: Response to cosmic muons of scintillator-SiPM asse…

200 papers

This study explores the feasibility of using scintillation detectors for muon calorimetry through experiments conducted at CERN's T10 beamline. Results from organic scintillators with varying thicknesses and readout methods, as well as a…

Precision calorimetry using highly granular sampling calorimeters is being developed based on the particle flow concept within the CALICE collaboration. One design option of a hadron calorimeter is based on silicon photomultipliers (SiPMs)…

Balloon- and space-borne cosmic-ray experiments employ plastic scintillators read out by silicon photomultipliers (SiPMs) to achieve picosecond-level time resolutions for triggering and particle identification. The performance of these…

Instrumentation and Detectors · Physics 2025-11-14 José Reyes Castillo , Saúl Aguilar Salazar , Diego Mauricio Gomez Coral

We present a novel geometry of scintillator tiles developed for fiberless coupling to silicon photomultipliers (SiPMs) for applications in highly granular calorimeters. A high degree of uniformity of the tile response over the full active…

Instrumentation and Detectors · Physics 2010-12-13 Frank Simon , Christian Soldner

We are developing a novel high-brightness atomic beam, comprised of a two-body exotic atom called muonium (M $ = \mu^+ + e^-$), for next-generation atomic physics and gravitational interaction measurements. This M source originates from a…

Instrumentation and Detectors · Physics 2022-06-29 J. Zhang , D. Goeldi , R. Iwai , M. Sakurai , A. Soter

To achieve the physics goal of precisely measure the Higgs, Z, W bosons and the top quark, future electron-positron colliders require that their detector system has excellent jet energy resolution. One feasible technical option is the high…

The advent of the silicon photomultiplier has allowed the development of highly segmented calorimeters using plastic scintillator as the active media, with photodetectors embedded in the calorimeter, in dimples in the plastic. To reduce the…

Instrumentation and Detectors · Physics 2024-01-23 B. Kronheim , A. Belloni , T. K. Edberg , S. C. Eno , C. Howe , C. Palmer , C. Papageorgakis , M. Paranjpe , S. Sriram

The SiPM-on-Tile technology for highly granular calorimeters, where small plastic scintillator tiles are directly read out with SiPMs, has been developed for the CALICE Analog Hadron Calorimeter, and has been adopted for parts of the…

Instrumentation and Detectors · Physics 2025-09-04 Fabian Hummer , Lorenz Emberger , Frank Simon

In this paper we discuss a general approach to use SiPMs in different electrical configurations in combination with numerous scintillator materials for applications in nuclear instrumentation, such as calorimetry and timing. The "hybrid"…

Instrumentation and Detectors · Physics 2018-11-08 Lukas Nies , Hans-Georg Zaunick , Kai-Thomas Brinkmann

A highly granular hadronic calorimeter (HCAL) based on scintillator tiles with individual readout by silicon photomultipliers (SiPMs) has been constructed by the CALICE collaboration and has been tested extensively in particle beams at…

Instrumentation and Detectors · Physics 2019-08-13 Frank Simon

The SiPM-on-tile technology, consisting of plastic scintillator tiles with typical sizes of a few cm$^2$ mounted on top of SiPMs, has been developed within the CALICE collaboration to enable automatized mass production of active elements…

Instrumentation and Detectors · Physics 2020-07-09 L. M. S. de Silva , F. Simon

The cosmic ray veto detector for the Mu2e experiment consists of scintillation bars embedded with wavelength-shifting fibers and read out by silicon photomultipliers (SiPMs). In this manuscript the calibration procedures of the SiPMs are…

Silicon photomultipliers (SiPMs) are a good alternative to photomultiplier tubes (PMTs) because their gain and quantum efficiency are comparable to PMTs. However, the largest single-chip SiPM is still less than 1~cm$^2$. In order to use…

Instrumentation and Detectors · Physics 2017-11-17 Felix Liang , Hartmut Brands , Les Hoy , Jeff Preston , Jason Smith

Imaging hadronic calorimeters with scintillator readout use small scintillator tiles individually read out by silicon photomultipliers to achieve the necessary granularity needed for sophisticated reconstruction algorithms at future…

Instrumentation and Detectors · Physics 2019-08-13 Frank Simon

Future cryogenic experiments searching for rare events require reliable, efficient and robust techniques for the detection of photons at temperatures well below that to which low-temperature photomultipliers (PMT) were characterised.…

Nuclear Experiment · Physics 2010-05-24 H. Kraus , V. B. Mikhailik

A study has been performed to understand the effects of radiation damage on various plastic scintillator tiles considered for a possible upgrade of the hadron calorimeter of the CMS detector. Measurements were made with unirradiated tiles…

Instrumentation and Detectors · Physics 2024-09-30 The CMS HCAL Collaboration

The advent of silicon photomultipliers has enabled big advances in high energy physics instrumentation, for example by allowing the construction of extremely granular hadronic calorimeters with photon sensors integrated into small…

Instrumentation and Detectors · Physics 2019-08-13 Christian Soldner

Muon scattering tomography is a non-destructive technique used to image different materials by utilizing natural cosmic ray muons. Typically it requires position-sensitive detectors with a sub-millimeter resolution to effectively…

Instrumentation and Detectors · Physics 2025-02-19 Binghao Sun , Huiling Li , Quanyin Li , Hui Liang , Cong Liu , Hongbo Wang , Zibing Wu , Suyu Xiao , Weiwei Xu

We report on several versions of the calibration and monitoring system dedicated to scintillator tile calorimeters built within the CALICE collaboration and intended for future linear collider experiments. Whereas the first, a 1 m3 analogue…

Instrumentation and Detectors · Physics 2019-08-15 Jaroslav Zalesak

Plastic scintillator detectors have been studied as dosimeters, since they provide a cost-effective alternative to conventional ionization chambers. On the other hand, several articles have reported undesired response dependencies on beam…

Instrumentation and Detectors · Physics 2017-12-05 Luis Peralta
‹ Prev 1 2 3 10 Next ›