English
Related papers

Related papers: MuGrid-v2: A novel scintillator detector for multi…

200 papers

Three-dimensional finely grained plastic scintillator detectors bring many advantages in particle detectors, allowing a massive active target which enables a high-precision tracking of interaction products, excellent calorimetry and a…

Vertex-reconstructed muon-spin spectroscopy (vx-{\mu}SR) based on silicon pixel detectors has recently demonstrated unprecedented lateral resolution and operation at muon stop rates exceeding 400 kHz. However, the intrinsic timing…

In this contribution we describe a novel solution for the construction of Positron Emission Tomograph. We present the device allowing for determination of the impact position as well as time and deph of interaction of the annihilation gamma…

Medical Physics · Physics 2013-10-15 P. Moskal , P. Salabura , M. Silarski , J. Smyrski , J. Zdebik , M. Zieliński

The article considers a prototype module with sensitive dimensions of 2 x 0.5 m2 based on 2 m long straw tubes which preserves its geometrical dimensions up to the pressure of 4 bar independently of the ambient temperature and humidity. The…

Instrumentation and Detectors · Physics 2012-10-23 V. Peshekhonov , K. Davkov , V. Myalkovskiy , N. Russakovich , I. Zhukov

Muography is an investigation technique based on the detection of the atmospheric muon flux' modification through matter. It has found lately multiple applications in geosciences, archaelogy, and non invasive industrial controls. Mostly…

Geophysics · Physics 2024-03-04 Theodore Avgitas , Jean-Christophe Ianigro , Jacques Marteau

SuperFGD, a highly granular scintillator detector, is under construction to reduce systematic uncertainties in the T2K experiment in order to improve the sensitivity to CP-violation in neutrino oscillations. SuperFGD will be comprised of…

Muon scattering tomography is a non-destructive technique used to image different materials by utilizing natural cosmic ray muons. Typically it requires position-sensitive detectors with a sub-millimeter resolution to effectively…

Instrumentation and Detectors · Physics 2025-02-19 Binghao Sun , Huiling Li , Quanyin Li , Hui Liang , Cong Liu , Hongbo Wang , Zibing Wu , Suyu Xiao , Weiwei Xu

We report on the design and commissioning of a new spectrometer for muon-spin relaxation/rotation studies installed at the Swiss Muon Source (S$\mu$S) of the Paul Scherrer Institute (PSI, Switzerland). This new instrument is essentially a…

Instrumentation and Detectors · Physics 2017-10-03 A. Amato , H. Luetkens , K. Sedlak , A. Stoykov , R. Scheuermann , M. Elender , A. Raselli , D. Graf

As part of the collaboration building a set of detectors for the new collider, our group was tasked with designing and building a large-scale cosmic ray detector, which was to complement the capabilities of the MPD (Dubna) detec-tor set.…

The MUonE experiment has been proposed to measure the differential cross section of $\mu e$ elastic scattering, by colliding the 160 GeV muons of the CERN M2 beam with atomic electrons of thin target plates. From a very precise measurement…

Instrumentation and Detectors · Physics 2024-04-26 Giovanni Abbiendi

A combination of scintillator, wavelength shifting (WLS) fiber, and silicon photomultiplier (SiPM) shows an excellent performance in the `$K_{L}$ and $\mu$ detector (KLM)' of the Belle II experiment. In this study, we present the R&D…

Instrumentation and Detectors · Physics 2024-05-22 Hongyu Zhang , Xiyang Wang , Weihu Ma , Shiming Zou , Deqing Fang , Wanbing He , Xiaolong Wang , Zhen Wang , Rui Yuan , Qibin Zheng

This paper reports on the design and construction of a chamber for the muon identifier detector (MID) of the ALICE 3 upgrade project. The chamber consists of two sensitive layers separated by a 1 cm air gap. Each layer holds 24 scintillator…

The NUCLEUS experiment aims at measuring the coherent elastic scattering of nuclear reactor antineutrinos off nuclei using cryogenic calorimeters. Operating at an overburden of 3m.w.e., muon-induced backgrounds are expected to be dominant.…

This work investigates the production of high-resolution images of typical support elements in concrete structures by means of muon tomography (muography). By exploiting detailed Monte Carlo radiation-matter simulations, we demonstrate the…

To achieve the physics goal of precisely measure the Higgs, Z, W bosons and the top quark, future electron-positron colliders require that their detector system has excellent jet energy resolution. One feasible technical option is the high…

In this paper, we present development of a portable cosmic muon tracker tailored for both on-site measurements of cosmic muon flux as well as for outreach activities. The tracker comprises of two 70 mm x 70 mm plastic scintillators,…

Instrumentation and Detectors · Physics 2026-03-02 Yuvaraj Elangovan , Shashwat Kakkad , B. Satyanarayana

The muon detectors of the experiments at the Large Hadron Collider (LHC) have to cope with unprecedentedly high neutron and gamma ray background rates. In the forward regions of the muon spectrometer of the ATLAS detector, for instance,…

Instrumentation and Detectors · Physics 2016-10-04 B. Bittner , J. Dubbert , O. Kortner , H. Kroha , F. Legger , R. Richter , O. Biebel , A. Engl , R. Hertenberger , F. Rauscher

Cosmic ray muon has strong penetrating power and no ionizing radiation hazards, which makes it an ideal probe for detecting special nuclear materials. In this paper, a high spatial resolution muon tomography system based on Micromegas…

Instrumentation and Detectors · Physics 2022-02-16 Yu Wang , Zhiyong Zhang , Shubin Liu , Zhongtao Shen , Changqing Feng , Jianguo Liu , Yulin Liu

The central detector in the MuSun experiment is a pad-plane time projection ionization chamber that operates without gas amplification in deuterium at 31 K; it is used to measure the rate of the muon capture process $\mu^- + d \rightarrow n…

A compact and fast electromagnetic calorimeter prototype was designed, built, and tested in preparation for a next-generation, high-rate muon g-2 experiment. It uses a simple assembly procedure: alternating layers of 0.5-mm-thick tungsten…

Instrumentation and Detectors · Physics 2009-10-06 R. McNabb , J. Blackburn , J. D. Crnkovic , D. W. Hertzog , B. Kiburg , J. Kunkle , E. Thorsland , D. M. Webber , K. R. Lynch
‹ Prev 1 3 4 5 6 7 10 Next ›