Related papers: ProTCT: Projection quantification and fidelity con…
Undersampled CT volumes minimize acquisition time and radiation exposure but introduce artifacts degrading image quality and diagnostic utility. Reducing these artifacts is critical for high-quality imaging. We propose a computationally…
Turbulence-degraded image frames are distorted by both turbulent deformations and space-time-varying blurs. To suppress these effects, we propose a multi-frame reconstruction scheme to recover a latent image from the observed image…
PURPOSE: We develop a practical, iterative algorithm for image-reconstruction in under-sampled tomographic systems, such as digital breast tomosynthesis (DBT). METHOD: The algorithm controls image regularity by minimizing the image total…
Spectral compressive imaging (SCI) is able to encode the high-dimensional hyperspectral image to a 2D measurement, and then uses algorithms to reconstruct the spatio-spectral data-cube. At present, the main bottleneck of SCI is the…
We introduce ICE-TIDE, a method for cryogenic electron tomography (cryo-ET) that simultaneously aligns observations and reconstructs a high-resolution volume. The alignment of tilt series in cryo-ET is a major problem limiting the…
Medical imaging based prostate cancer diagnosis procedure uses intra-operative transrectal ultrasound (TRUS) imaging to visualize the prostate shape and location to collect tissue samples. Correct tissue sampling from prostate requires…
X-ray computed tomographic infrastructures are medical imaging modalities that rely on the acquisition of rays crossing examined objects while measuring their intensity decrease. Physical measurements are post-processed by mathematical…
Deep learning-based models have demonstrated remarkable success in solving illposed inverse problems; however, many fail to strictly adhere to the physical constraints imposed by the measurement process. In this work, we introduce a…
The high computational demands of Vision Transformers (ViTs) in processing a large number of tokens often constrain their practical application in analyzing medical images. This research proposes a Prompt-driven Adaptive Token ({\it PrATo})…
Sparse-View Computed Tomography (SVCT) offers low-dose and fast imaging but suffers from severe artifacts. Optimizing the sampling strategy is an essential approach to improving the imaging quality of SVCT. However, current methods…
Ptychography in a reflection geometry shows great promise for non-destructive imaging of 3-dimensional nanostructures at the surface of a thick substrate. A major challenge to obtain high quality reflection-ptychographic images under…
Photoacoustic computed tomography (PACT) is an emerging computed imaging modality that exploits optical contrast and ultrasonic detection principles to form images of the absorbed optical energy density within tissue. If the object…
This paper concerns a fast, one-step iterative technique of imaging extended perfectly conducting cracks with Dirichlet boundary condition. In order to reconstruct the shape of cracks from scattered field data measured at the boundary, we…
Spectral computed tomography has received considerable interest in recent years since spectral measurements contain much richer information about the object of interest. In spectral computed tomography, we are interested in the energy…
Image reconstruction from insufficient data is common in computed tomography (CT), e.g., image reconstruction from truncated data, limited-angle data and sparse-view data. Deep learning has achieved impressive results in this field.…
Vision Transformers (ViTs) have emerged as state-of-the-art models for various vision tasks recently. However, their heavy computation costs remain daunting for resource-limited devices. To address this, researchers have dedicated…
Estimating accurate 3D locations of objects from monocular images is a challenging problem because of lacking depth. Previous work shows that utilizing the object's keypoint projection constraints to estimate multiple depth candidates…
Computed tomography (CT) has become an essential part of modern science and medicine. A CT scanner consists of an X-ray source that is spun around an object of interest. On the opposite end of the X-ray source, a detector captures X-rays…
Spectral domain optical coherence tomography (OCT) offers high resolution multidimensional imaging, but generally suffers from defocussing, intensity falloff and shot noise, causing artifacts and image degradation along the imaging depth.…
Limited-Angle Computed Tomography (LACT) is a non-destructive evaluation technique used in a variety of applications ranging from security to medicine. The limited angle coverage in LACT is often a dominant source of severe artifacts in the…