English
Related papers

Related papers: Development, Characterization, and Testing of a Bi…

200 papers

A Cosmic Muon Veto Detector (CMVD) is being built around the mini-Iron Calorimeter (mini-ICAL) detector at the transit campus of the India based Neutrino Observatory, Madurai. The CMV detector will be made using extruded plastic…

A Cosmic Muon Veto (CMV) detector using extruded plastic scintillators is being designed around the mini-Iron Calorimeter (mini-ICAL) detector at the transit campus of the India based Neutrino Observatory, Madurai for the feasibility study…

A Cosmic Muon Veto (CMV) detector using extruded scintillators is being designed around the mini-Iron Calorimeter detector at the transit campus of the India-based Neutrino Observatory at Madurai for measuring its efficiency at shallow…

The India-Based Neutrino Observatory (INO) collaboration houses the miniICAL detector, at the transit campus of IICHEP, Madurai, India, which serves as a prototype-detector of the larger Iron-Calorimeter detector (ICAL). The purpose of…

High Energy Physics - Experiment · Physics 2024-07-17 Raj Shah , Gobinda Majumder

The INO collaboration is designing a cosmic muon veto detector (CMVD) to cover the mini-ICAL detector which is operational at the IICHEP transit campus, Madurai in South India. The aim of the CMVD is to study the feasibility of building an…

We report the characterisation of a FBK NUV-HD-cryo silicon photomultiplier (SiPM) sensor operated in a 9.4 $\pm$ 0.2 mK environment inside a dilution refrigerator, towards the development of a cryogenic cosmic ray muon veto system to be…

In this paper, we present development of a portable cosmic muon tracker tailored for both on-site measurements of cosmic muon flux as well as for outreach activities. The tracker comprises of two 70 mm x 70 mm plastic scintillators,…

Instrumentation and Detectors · Physics 2026-03-02 Yuvaraj Elangovan , Shashwat Kakkad , B. Satyanarayana

A combination of scintillator, wavelength shifting (WLS) fiber, and silicon photomultiplier (SiPM) shows an excellent performance in the `$K_{L}$ and $\mu$ detector (KLM)' of the Belle II experiment. In this study, we present the R&D…

Instrumentation and Detectors · Physics 2024-05-22 Hongyu Zhang , Xiyang Wang , Weihu Ma , Shiming Zou , Deqing Fang , Wanbing He , Xiaolong Wang , Zhen Wang , Rui Yuan , Qibin Zheng

CUPID will be a next-generation experiment searching for neutrinoless double beta decay in the inverted mass ordering regime. The reduction of backgrounds in the region of interest is critical to the performance of the experiment. Despite…

Muon tomography is a non-destructive imaging technique that uses cosmic-ray muons to probe dense materials. Bar scintillator and scintillating fiber detectors equipped with one-dimensional SiPM arrays offer compact, high-resolution…

Instrumentation and Detectors · Physics 2026-04-06 Chenghan Lv , Kun Hu , Huiling Li , Hui Liang , Cong Liu , Hongbo Wang , Zibing Wu , Weiwei Xu

The cosmic ray veto detector for the Mu2e experiment consists of scintillation bars embedded with wavelength-shifting fibers and read out by silicon photomultipliers (SiPMs). In this manuscript the calibration procedures of the SiPMs are…

Muon scattering tomography is a non-destructive technique used to image different materials by utilizing natural cosmic ray muons. Typically it requires position-sensitive detectors with a sub-millimeter resolution to effectively…

Instrumentation and Detectors · Physics 2025-02-19 Binghao Sun , Huiling Li , Quanyin Li , Hui Liang , Cong Liu , Hongbo Wang , Zibing Wu , Suyu Xiao , Weiwei Xu

Silicon photo-multipliers (SiPMs) are state-of-the-art sensors capable of detecting a single photoelectron under cryogenic conditions, with potentially lower radioactivity than widely used photomultiplier tubes. The DarkSide-20k experiment,…

Instrumentation and Detectors · Physics 2026-04-06 20k collaboration

The Micro Vertex Detector (MVD) is the most upstream detector of the fixed-target Compressed Baryonic Matter Experiment (CBM) at the future Facility for Antiproton and Ion Research (FAIR). It enables high-precision low-momentum tracking in…

We developed a compact and rugged muon detector designed for deployment in boreholes. The detector uses a SiPM-on-tile approach in which silicon photomultipliers are directly coupled to scintillator tiles, thereby eliminating the need for…

Instrumentation and Detectors · Physics 2025-10-07 Miguel Arratia , Jiajun Huang , Sean Preins , Sebastian Ritter , Christian P. Romero , Sebastian Tapia

We present the upgraded design, construction, and beam test results for the Muon Trigger Detector (MTD) developed for the muon Electric Dipole Moment (muEDM) experiment at the Paul Scherrer Institute (PSI) in Switzerland. This experiment…

To fully exploit the HERA-II upgrade,the ZEUS experiment has installed a Micro Vertex Detector (MVD) using n-type, single-sided, silicon micro-strip sensors with capacitive charge division. The sensors have a readout pitch of 120…

High Energy Physics - Experiment · Physics 2009-11-07 D. Dannheim , U. Koetz , C. Coldewey , E. Fretwurst , A. Garfagnini , R. Klanner , J. Martens , E. Koffeman , H. Tiecke , R. Carlin

The NUCLEUS experiment aims to measure coherent elastic neutrino nucleus scattering of reactor anti-neutrinos using cryogenic calorimeters. Operating at an overburden of 3 m.w.e., muon-induced backgrounds are expected to be one of the…

The barrel section of the novel MIP Timing Detector (MTD) will be constructed as part of the upgrade of the CMS experiment to provide a time resolution for single charged tracks in the range of $30-60$ ps using LYSO:Ce crystal arrays read…

The motivation of the current R&D project is based upon the requirements of the JEDI international collaboration aiming to measure Electric Dipole Moments (EDMs) of charged particles in storage rings. One of the most important elements of…

‹ Prev 1 2 3 10 Next ›