English
Related papers

Related papers: Closed-form expressions for the centroid-tilt erro…

200 papers

Increasing requirements in the sensitivity of interferometric measurements is a common feature of several research fields, from gravitational wave detection to quantum optics. This motivates refined studies of high reflectivity mirrors and…

We present a method to calibrate a high-resolution wavefront-correcting device with a single, static camera, located in the focal plane; no moving of any component is needed. The method is based on a localized diversity and differential…

Instrumentation and Methods for Astrophysics · Physics 2015-06-17 Visa Korkiakoski , Niek Doelman , Johanan Codona , Matthew Kenworthy , Gilles Otten , Christoph U. Keller

LINC-NIRVANA will realize the interferometric imaging focal station of the Large Binocular Telescope. A double Layer Oriented multi-conjugate adaptive optics system assists the two arms of the interferometer, supplying high order wave-front…

We present a new procedure for conducting a sensitivity analysis in matched observational studies. For any candidate test statistic, the approach defines tilted modifications dependent upon the proposed strength of unmeasured confounding.…

Methodology · Statistics 2025-03-14 Colin B. Fogarty

We report on a new measurement of the energy resolution that can be attained in liquid xenon when recording only the scintillation light. Our setup is optimized to maximize light collection, and uses state-of-the-art, high-PDE,…

This paper introduces a novel wavefront sensing approach that relies on the Fourier analysis of a single conventional direct image. In the high Strehl ratio regime, the relation between the phase measured in the Fourier plane and the…

Instrumentation and Methods for Astrophysics · Physics 2015-06-15 Frantz Martinache

A plastic scintillator bar with dimensions 300 cm x 2.5 cm x 11 cm was exposed to a focused muon beam to study its light yield and timing characteristics as a function of position and angle of incidence. The scintillating light was read out…

Instrumentation and Detectors · Physics 2017-08-07 A. Blondel , D. Breton , A. Dubreuil , A. Khotyantsev , A. Korzenev , J. Maalmi , A. Mefodev , P. Mermod , E. Noah

The scintillation characteristics of 1 g undoped CsI crystal were studied by directly coupling two silicon photomultipliers(SiPMs) over a temperature range from room temperature to 86 K. The scintillation decay time and light output were…

Instrumentation and Detectors · Physics 2025-08-01 W. K. Kim , H. Y. Lee , K. W. Kim , Y. J. Ko , J. A. Jeon , H. J. Kim , H. S. Lee

Context. Interstellar scintillation (ISS) of pulsar emission can be used both as a probe of the ionised interstellar medium (IISM) and cause corruptions in pulsar timing experiments. Of particular interest are so-called scintillation arcs…

The mesoscale model Meso-NH is used to simulate the optical turbulence at Mt Graham (Arizona, USA), site of the Large Binocular Telescope. Measurements of the CN2-profiles obtained with a generalized scidar from 41 nights are used to…

Instrumentation and Methods for Astrophysics · Physics 2011-05-16 S. Hagelin , E. Masciadri , F. Lascaux

We describe an atom interferometer to study the coherence of atoms reflected from an evanescent wave mirror. The interferometer is sensitive to the loss of phase coherence induced by the defects in the mirror. The results are consistent…

A hybrid dual-readout calorimeter concept, comprising both electromagnetic and hadronic sections, has recently been proposed to meet the performance requirements of experiments at future e$^{+}$e$^{-}$ colliders. The front compartment…

Instrumentation and Detectors · Physics 2026-03-20 Andrea Benaglia , Flavia Cetorelli , Marco Toliman Lucchini , Etiennette Auffray , Louis Roux , Julie Delenne

Classical discrete-time adaptive controllers provide asymptotic stabilization and tracking; neither exponential stabilization nor a bounded noise gain is typically proven. In recent work it has been shown, in both the pole placement…

Optimization and Control · Mathematics 2019-02-26 Daniel E Miller , Mohamad T. Shahab

The Multi Aperture Scintillation Sensor (MASS) and the Generalized-Scintillation Detection and Ranging (Generalized SCIDAR) are two instruments conceived to measure the optical turbulence (OT) vertical distribution on the whole troposphere…

Instrumentation and Methods for Astrophysics · Physics 2013-11-12 E. Masciadri , G. Lombardi , F. Lascaux

In coherent diffraction imaging (CDI) experiments, the intensity of the scattered wave impinging on an object is measured on an array of detectors. This signal can be interpreted as the square of the modulus of the Fourier transform of the…

We present a detailed study of the center-of-mass (c.m.) motion seen in simulations produced by the Simulating eXtreme Spacetimes (SXS) collaboration. We investigate potential physical sources for the large c.m. motion in binary black hole…

General Relativity and Quantum Cosmology · Physics 2019-12-12 Charles J. Woodford , Michael Boyle , Harald P. Pfeiffer

Scintillating homogeneous detectors represent the state of the art in electromagnetic calorimetry. Moreover, the currently neglected crystalline nature of the most common inorganic scintillators can be exploited to achieve an outstanding…

Visibility scintillation resulting from wave propagation through the turbulent ionosphere can be an important sources of noise at low radio frequencies ($\nu\lesssim 200$ MHz). Many low frequency experiments are underway to detect the power…

Instrumentation and Methods for Astrophysics · Physics 2016-03-16 H. K. Vedantham , L. V. E. Koopmans

Modern precise radial velocity spectrometers are designed to infer the existence of planets orbiting other stars by measuring few-nm shifts in the positions of stellar spectral lines recorded at high spectral resolution on a large-area…

Instrumentation and Methods for Astrophysics · Physics 2019-09-24 Cullen H. Blake , Dan Li , Joseph R. Tufts , Joe Ninan , Suvrath Mahadevan , Chad Bender , Fred R. Hearty , Andy Monson , Mark Giovinazzi

Residual wavefront errors in optical elements limit the performance of coronagraphs. To improve their efficiency, different types of devices have been proposed to correct or calibrate these errors. In this paper, we study one of these…

Astrophysics · Physics 2009-03-19 R. Galicher , P. Baudoz