English
Related papers

Related papers: The Imaging Time-of-Propagation Detector at Belle …

200 papers

The Time-Of-Propagation detector is a Cherenkov particle identification detector based on quartz radiator bars for the Belle II experiment at the SuperKEKB electron-positron collider. The purpose of the detector is to identify the type of…

High-efficiency and high-purity particle identification are fundamental requirements for the success of the Belle II experiment, whose main goal is to explore the new-physics scenarios in the CP-violating decays of the B mesons. To achieve…

High Energy Physics - Experiment · Physics 2018-11-13 Umberto Tamponi

The Time-Of-Propagation (TOP) counter is a novel device for particle identification for the barrel region of the Belle II experiment, where, information of Cherenkov light propagation time is used to reconstruct its ring image. We…

Instrumentation and Detectors · Physics 2019-08-14 Y. Maeda

The Belle II detector operating at the future upgrade to the KEKB accelerator will perform high-statistics precision investigations into the flavor sector of the Standard Model. As charged hadron identification is a vital element of the…

Instrumentation and Detectors · Physics 2019-08-14 K. Nishimura

The barrel-region particle identification detector is crucial for extending the physics reach of the Belle II experiment operating at the SuperKEKB accelerator. For this purpose, an imaging-Time-of-Propagation (iTOP) counter was developed,…

Instrumentation and Detectors · Physics 2017-10-10 Boqun Wang

Particle identification at the Belle II experiment will be provided by two ring imaging Cherenkov devices, the time of propagation counters in the central region and the proximity focusing RICH with aerogel radiator in the forward end-cap…

Instrumentation and Detectors · Physics 2017-06-28 S. Sandilya

The Belle-II experiment and superKEKB accelerator will form a next generation B-factory at KEK, capable of running at an instantaneous luminosity 40 times higher than the Belle detector and KEKB. This will allow for the elucidation of many…

Instrumentation and Detectors · Physics 2013-10-18 Matthew Barrett

The Time-Of-Propagation (TOP) counter is a ring-imaging Cherenkov detector designed to identify the charged hadrons in the barrel region of the Belle II detector. The Belle II experiment collected data delivered by the SuperKEKB accelerator…

Instrumentation and Detectors · Physics 2025-02-12 Ezio Torassa

At the Belle II experiment a Time-of-Propagation (TOP) counter is used for particle identification in the barrel region. This novel type of particle identification device combines the Cherenkov ring imaging technique with the time-of-flight…

High Energy Physics - Experiment · Physics 2023-07-19 Marko Staric

Super B factories that will further probe the flavor sector of the Standard Model and physics beyond will demand excellent charged particle identification (PID), particularly K/pi separation, for momenta up to 4 GeV/c, as well as the…

Instrumentation and Detectors · Physics 2014-11-20 K. Nishimura , T. Browder , H. Hoedlmoser , B. Jacobson , J. Kennedy , M. Rosen , L. Ruckman , G. Varner , A. Wong , W. Yen

The imaging-Time-of-Propogation (iTOP) counter is a new type of ring-imaging Cherenkov counter developed for particle identification at the Belle II experiment. It consists of 16 modules arranged azimuthally around the beam line. Each…

Instrumentation and Detectors · Physics 2017-10-09 Boqun Wang , Saurabh Sandilya , Bilas Pal , Alan Schwartz

We report on the charged particle identification (PID) systems for the upcoming Belle II experiment. The time of propagation counter in the central region and the proximity focusing ring imaging Cherenkov counters with aerogel radiator in…

Instrumentation and Detectors · Physics 2017-01-04 S. Sandilya

The Belle II experiment's ability to identify particles critically affects the sensitivity of its measurements. We describe Belle II's algorithms for identifying charged particles and evaluate their performance in separating pions, kaons,…

High Energy Physics - Experiment · Physics 2025-11-04 Belle II Collaboration , I. Adachi , H. Ahmed , Y. Ahn , H. Aihara , N. Akopov , A. Albert , S. Alghamdi , M. Alhakami , A. Aloisio , N. Althubiti , K. Amos , M. Angelsmark , N. Anh Ky , C. Antonioli , D. M. Asner , H. Atmacan , T. Aushev , V. Aushev , M. Aversano , R. Ayad , V. Babu , H. Bae , N. K. Baghel , S. Bahinipati , P. Bambade , Sw. Banerjee , M. Barrett , M. Bartl , J. Baudot , A. Baur , A. Beaubien , F. Becherer , J. Becker , J. V. Bennett , F. U. Bernlochner , V. Bertacchi , M. Bertemes , E. Bertholet , M. Bessner , S. Bettarini , B. Bhuyan , F. Bianchi , T. Bilka , D. Biswas , A. Bobrov , D. Bodrov , A. Bondar , G. Bonvicini , J. Borah , A. Boschetti , A. Bozek , M. Bračko , P. Branchini , R. A. Briere , T. E. Browder , A. Budano , S. Bussino , Q. Campagna , M. Campajola , L. Cao , G. Casarosa , C. Cecchi , M. -C. Chang , P. Cheema , L. Chen , Y. -T. Chen , B. G. Cheon , K. Chilikin , J. Chin , K. Chirapatpimol , H. -E. Cho , K. Cho , S. -J. Cho , S. -K. Choi , S. Choudhury , J. Cochran , I. Consigny , L. Corona , J. X. Cui , S. Das , E. De La Cruz-Burelo , S. A. De La Motte , G. De Pietro , R. de Sangro , M. Destefanis , S. Dey , A. Di Canto , J. Dingfelder , Z. Doležal , I. Domínguez Jiménez , T. V. Dong , M. Dorigo , G. Dujany , P. Ecker , J. Eppelt , R. Farkas , P. Feichtinger , T. Ferber , T. Fillinger , C. Finck , G. Finocchiaro , A. Fodor , F. Forti , A. Frey , B. G. Fulsom , A. Gabrielli , A. Gale , E. Ganiev , M. Garcia-Hernandez , R. Garg , G. Gaudino , V. Gaur , V. Gautam , A. Gaz , A. Gellrich , D. Ghosh , G. Giakoustidis , R. Giordano , A. Giri , P. Gironella Gironell , B. Gobbo , R. Godang , O. Gogota , P. Goldenzweig , W. Gradl , E. Graziani , D. Greenwald , Z. Gruberová , Y. Guan , K. Gudkova , I. Haide , Y. Han , K. Hayasaka , H. Hayashii , S. Hazra , M. T. Hedges , A. Heidelbach , G. Heine , I. Heredia de la Cruz , M. Hernández Villanueva , T. Higuchi , M. Hoek , M. Hohmann , R. Hoppe , P. Horak , C. -L. Hsu , A. Huang , T. Humair , T. Iijima , K. Inami , G. Inguglia , N. Ipsita , A. Ishikawa , R. Itoh , M. Iwasaki , P. Jackson , D. Jacobi , W. W. Jacobs , E. -J. Jang , Q. P. Ji , X. B. Ji , S. Jia , Y. Jin , A. Johnson , H. Junkerkalefeld , J. Kandra , K. H. Kang , G. Karyan , T. Kawasaki , F. Keil , C. Ketter , M. Khan , C. Kiesling , C. -H. Kim , D. Y. Kim , J. -Y. Kim , K. -H. Kim , K. Kinoshita , P. Kodyš , S. Kohani , K. Kojima , A. Korobov , S. Korpar , E. Kovalenko , R. Kowalewski , P. Križan , P. Krokovny , Y. Kulii , J. Kumar , K. Kumara , T. Kunigo , A. Kuzmin , Y. -J. Kwon , S. Lacaprara , K. Lalwani , T. Lam , L. Lanceri , J. S. Lange , T. S. Lau , M. Laurenza , R. Leboucher , F. R. Le Diberder , M. J. Lee , P. Leo , P. M. Lewis , C. Li , H. -J. Li , L. K. Li , Q. M. Li , W. Z. Li , Y. Li , Y. B. Li , Y. P. Liao , J. Libby , J. Lin , S. Lin , V. Lisovskyi , M. H. Liu , Q. Y. Liu , Y. Liu , Z. Q. Liu , D. Liventsev , S. Longo , T. Lueck , C. Lyu , Y. Ma , C. Madaan , M. Maggiora , S. P. Maharana , R. Maiti , G. Mancinelli , R. Manfredi , E. Manoni , M. Mantovano , D. Marcantonio , S. Marcello , C. Marinas , C. Martellini , A. Martens , T. Martinov , L. Massaccesi , M. Masuda , K. Matsuoka , D. Matvienko , M. Maushart , J. A. McKenna , R. Mehta , F. Meier , D. Meleshko , M. Merola , C. Miller , M. Mirra , S. Mitra , K. Miyabayashi , G. B. Mohanty , S. Moneta , A. L. Moreira de Carvalho , H. -G. Moser , R. Mussa , I. Nakamura , M. Nakao , Y. Nakazawa , M. Naruki , Z. Natkaniec , A. Natochii , M. Nayak , M. Neu , S. Nishida , A. Novosel , S. Ogawa , R. Okubo , H. Ono , E. R. Oxford , G. Pakhlova , S. Pardi , K. Parham , J. Park , K. Park , S. -H. Park , A. Passeri , S. Patra , R. Peschke , R. Pestotnik , L. E. Piilonen , P. L. M. Podesta-Lerma , T. Podobnik , A. Prakash , C. Praz , S. Prell , E. Prencipe , M. T. Prim , S. Privalov , H. Purwar , P. Rados , G. Raeuber , S. Raiz , V. Raj , K. Ravindran , J. U. Rehman , M. Reif , S. Reiter , M. Remnev , L. Reuter , D. Ricalde Herrmann , I. Ripp-Baudot , G. Rizzo , J. M. Roney , A. Rostomyan , N. Rout , D. A. Sanders , S. Sandilya , L. Santelj , V. Savinov , B. Scavino , J. Schmitz , S. Schneider , M. Schnepf , C. Schwanda , A. J. Schwartz , Y. Seino , A. Selce , K. Senyo , J. Serrano , M. E. Sevior , C. Sfienti , W. Shan , X. D. Shi , T. Shillington , J. -G. Shiu , D. Shtol , A. Sibidanov , X. Simo , F. Simon , J. B. Singh , J. Skorupa , R. J. Sobie , M. Sobotzik , A. Soffer , A. Sokolov , E. Solovieva , S. Spataro , B. Spruck , M. Starič , P. Stavroulakis , S. Stefkova , R. Stroili , Y. Sue , M. Sumihama , K. Sumisawa , N. Suwonjandee , H. Svidras , M. Takahashi , M. Takizawa , U. Tamponi , K. Tanida , F. Tenchini , F. Testa , O. Tittel , R. Tiwary , E. Torassa , K. Trabelsi , F. F. Trantou , I. Tsaklidis , I. Ueda , E. Uenlue , T. Uglov , K. Unger , Y. Unno , K. Uno , S. Uno , P. Urquijo , Y. Ushiroda , S. E. Vahsen , R. van Tonder , K. E. Varvell , M. Veronesi , V. S. Vismaya , L. Vitale , V. Vobbilisetti , R. Volpe , A. Vossen , M. Wakai , S. Wallner , M. -Z. Wang , Z. Wang , A. Warburton , M. Watanabe , S. Watanuki , C. Wessel , E. Won , X. P. Xu , B. D. Yabsley , S. Yamada , W. Yan , W. C. Yan , S. B. Yang , J. Yelton , K. Yi , J. H. Yin , K. Yoshihara , J. Yuan , Y. Yusa , L. Zani , F. Zeng , M. Zeyrek , B. Zhang , J. S. Zhou , Q. D. Zhou , L. Zhu , R. Žlebčík

We report on the design, operation, and performance of a novel proximity-focusing Ring Imaging Cherenkov (RICH) detector equipped with a multilayer focusing aerogel radiator, developed for the forward region of the Belle II spectrometer at…

A new type of ring-imaging Cherenkov counter, called TOP counter, has been developed for particle identification at the Belle II experiment to run at the SuperKEKB accelerator in KEK, Japan. The detector consists of 16 identical modules…

Instrumentation and Detectors · Physics 2019-08-14 Boqun Wang

A new concept concerning Cherenkov detector for particle identification by means of measuring both the Time-of-Propagation (TOP) and horizontal emission angle ($\Phi$) of Cherenkov photons is described here. Some R&D works are also…

High Energy Physics - Experiment · Physics 2009-10-31 Takayoshi Ohshima

The innovative Barrel DIRC (Detection of Internally Reflected Cherenkov light) counter will provide hadronic particle identification (PID) in the central region of the PANDA experiment at the new Facility for Antiproton and Ion Research…

We describe here a new concept of a Cherenkov detector for particle identification by means of measuring the Time-of-Propagation (TOP) of Cherenkov photons.

We have developed particle detectors based on fused silica (quartz) Cherenkov radiators read out with micro-channel plate photomultipliers (MCP-PMTs) or silicon photomultipliers (SiPMs) for high precision timing (Sigma(t) about 10-15 ps).…

Instrumentation and Detectors · Physics 2015-06-05 M. G. Albrow , Heejong Kim , S. Los , E. Ramberg , A. Ronzhin , V. Samoylenko , H. Wenzel , A. Zatserklyaniy

The Belle II experiment at the SuperKEKB collider in Japan is designed to indirectly probe new physics using approximately 50 times the data recorded by its predecessor. An accurate determination of the decay-point position of subatomic…

Instrumentation and Detectors · Physics 2016-04-07 Gagan B. Mohanty
‹ Prev 1 2 3 10 Next ›