Related papers: Performance Study of a Position-sensitive Plastic …
A new method for directional fast neutron detection is proposed based on a neutron time projection chamber (TPC) and position-sensitive plastic scintillation detectors. The detection system can efficiently locate the approximate location of…
Silicon photomultipliers (SiPMs) have become the baseline choice for cameras of the small-sized telescopes (SSTs) of the Cherenkov Telescope Array (CTA). On the other hand, SiPMs are relatively new to the field and covering large surfaces…
The use of silicon photomultipliers (SiPMs) alongside conventional photomultiplier tubes (PMTs) is a remarkable technological development in modern ground-based very high energy gamma-ray astronomy. SiPMs exhibit comparable or even higher…
The last decade has increasingly seen the use of silicon photomultipliers (SiPMs) instead of photomultiplier tubes (PMTs). This is due to various advantages of the former on the latter like its smaller size, lower operating voltage, higher…
The signals received from the optical receivers like as SiPM and PMT due to the collision of energetic particles with the scintillators attached to these optical receivers, are weak and fast. To measure the number of signals as well as…
In this work, the simulation of optical photons is carried out in an antineutrino detector module consisting of a plastic scintillator connected to light guides and photomultipliers on both ends, which is considered to be used for remote…
Current clinical PET systems utilize detectors where the scintillator typically contains single elements of 3 - 6 mm width and about 20 mm height. While providing good TOF performance, this design limits the spatial resolution and causes…
Silicon photomultipliers (SiPM) are the photon detectors chosen for the tracking readout in NEXT, a neutrinoless {\beta}{\beta} decay experiment which uses a high pressure gaseous xenon time projection chamber (TPC). The reconstruction of…
The motivation of the current R&D project is based upon the requirements of the JEDI international collaboration aiming to measure Electric Dipole Moments (EDMs) of charged particles in storage rings. One of the most important elements of…
Scintillation detectors with excellent timing resolution enable more precise localization of radiation sources in positron emission tomography, leading to substantial improvements in diagnostic capability for diseases such as cancer and…
The demands on detectors for particle detection as well as for medical and astronomical X-ray imaging are continuously pushing the development of novel pixel detectors. The state of the art in pixel detector technology to date are hybrid…
Silicon Photomultipliers (SiPMs) are quickly replacing traditional photomultiplier tubes (PMTs) as the readout of choice for gamma-ray scintillation detectors in space. While they offer substantial size, weight and power saving, they have…
The construction of large-scale liquid scintillator detectors is complicated by the need to separate the scintillation region from photomultiplier tubes (PMTs) due to their intrinsic radioactivity. This is generally done using acrylic or…
Bioluminescence detection requires single-photon sensitivity, extremely low detection limits and wide dynamic range. Such performances were traditionally assured by photomultiplier-tubes based systems. However, development of novel…
Recent years have shown an increased use of silicon photo-multipliers (SiPM) in experiments as they are of reasonable cost, have relatively low power consumption and are easily available in a variety of form factors allowing for a large…
We are developing position sensitive silicon detectors (PSD) which have an electrode at each of four corners so that the incident position of a charged particle can be obtained using signals from the electrodes. It is expected that the…
This article presents a physics-informed deep learning method for the quantitative estimation of the spatial coordinates of gamma interactions within a monolithic scintillator, with a focus on Positron Emission Tomography (PET) imaging. A…
We report on studies of non-toxic scintillating liquid useful for large surface detectors. Arrays of liquid scintillators offer a rather simple tool for detecting charged particles traversing a surface and tracking their path through a…
In recent years, demand for scintillation detectors with high time resolution (better than 100 ps) has emerged in high-energy physics and medical imaging applications. In particular, time of flight positron emission tomography (TOF-PET) can…
The development prospects have been considered of a scintillator-photodiode type detector with improved energy resolution attaining several per cent ($R=1-2%$). The main contributions to the scintielectron detector energy resolution have…