English
Related papers

Related papers: Prior-Adapted Progressive Time-Resolved CBCT Recon…

200 papers

Motion correction aims to prevent motion artefacts which may be caused by respiration, heartbeat, or head movements for example. In a preliminary step, the measured data is divided in gates corresponding to motion states, and displacement…

Optimization and Control · Mathematics 2024-10-15 Claire Delplancke , Kris Thielemans , Matthias J. Ehrhardt

Conebeam CT using a circular trajectory is quite often used for various applications due to its relative simple geometry. For conebeam geometry, Feldkamp, Davis and Kress algorithm is regarded as the standard reconstruction method, but this…

Image and Video Processing · Electrical Eng. & Systems 2020-06-04 Yoseob Han , Junyoung Kim , Jong Chul Ye

Background: Daily or weekly cone-beam computed tomography (CBCT) scans are commonly used for accurate patient positioning during the image-guided radiotherapy (IGRT) process, making it an ideal option for adaptive radiotherapy (ART)…

This study proposes a novel imaging and reconstruction framework for dual-energy cone-beam CT (DECBCT) using only two orthogonal X-ray projections at different energy levels (2V-DECBCT). The goal is to enable fast and low-dose DE volumetric…

Medical Physics · Physics 2025-04-18 Junbo Peng , Tonghe Wang , Shaoyan Pan , Xiaofeng Yang

This paper presents a two-stage method for beam hardening artifact correction of dental cone beam computerized tomography (CBCT). The proposed artifact reduction method is designed to improve the quality of maxillofacial imaging, where soft…

Computational Engineering, Finance, and Science · Computer Science 2020-10-09 T. Bayaraa , C. M. Hyun , T. J. Jang , S. M. Lee , J. K. Seo

Contrast resolution beyond the limits of conventional cone-beam CT (CBCT) systems is essential to high-quality imaging of the brain. We present a deep learning reconstruction method (dubbed DL-Recon) that integrates physically principled…

Cone Beam Computed Tomography (CBCT) is widely used in medical imaging. However, the limited number and intensity of X-ray projections make reconstruction an ill-posed problem with severe artifacts. NeRF-based methods have achieved great…

Image and Video Processing · Electrical Eng. & Systems 2025-06-25 Zhuowei Xu , Han Li , Dai Sun , Zhicheng Li , Yujia Li , Qingpeng Kong , Zhiwei Cheng , Nassir Navab , S. Kevin Zhou

Total variation (TV) regularization is a popular reconstruction method for ill-posed imaging problems, and particularly useful for applications with piecewise constant targets. However, using TV for medical cone-beam computed X-ray…

Medical Physics · Physics 2024-12-11 Alexander Meaney , Mikael A. K. Brix , Miika T. Nieminen , Samuli Siltanen

Accurate reconstruction of arbitrary-shaped long slender continuum bodies, such as guidewires, catheters and other soft continuum manipulators, is essential for accurate mechanical simulation. However, existing image-based reconstruction…

Robotics · Computer Science 2026-03-25 Yaozhi Zhang , Shun Yu , Yugang Zhang , Yang Liu

Industrial X-ray cone-beam CT (XCT) scanners are widely used for scientific imaging and non-destructive characterization. Industrial CBCT scanners use large detectors containing millions of pixels and the subsequent 3D reconstructions can…

Image and Video Processing · Electrical Eng. & Systems 2025-01-24 Aniket Pramanik , Singanallur V. Venkatakrishnan , Obaidullah Rahman , Amirkoushyar Ziabari

Sparse views X-ray computed tomography has emerged as a contemporary technique to mitigate radiation dose. Because of the reduced number of projection views, traditional reconstruction methods can lead to severe artifacts. Recently,…

Computer Vision and Pattern Recognition · Computer Science 2024-09-04 Liutao Yang , Jiahao Huang , Guang Yang , Daoqiang Zhang

Over the last few years, neural image compression has gained wide attention from research and industry, yielding promising end-to-end deep neural codecs outperforming their conventional counterparts in rate-distortion performance. Despite…

Computer Vision and Pattern Recognition · Computer Science 2023-07-14 Ahmed Ghorbel , Wassim Hamidouche , Luce Morin

Accurate dose calculation on cone beam computed tomography (CBCT) images is essential for modern proton treatment planning workflows, particularly when accounting for inter-fractional anatomical changes in adaptive treatment scenarios.…

Cardiac cine magnetic resonance imaging (MRI) is one of the important means to assess cardiac functions and vascular abnormalities. Mitigating artifacts arising during image reconstruction and accelerating cardiac cine MRI acquisition to…

Image and Video Processing · Electrical Eng. & Systems 2024-07-03 Xiaoxiang Han , Yang Chen , Qiaohong Liu , Yiman Liu , Keyan Chen , Yuanjie Lin , Weikun Zhang

The purpose of this work is to provide a fast and accurate scatter artifacts correction algorithm for cone beam CT (CBCT) imaging. The method starts with an estimation of coarse scatter profiles for a set of CBCT data in either image domain…

Medical Physics · Physics 2016-04-27 Wei Zhao , Don Vernekohl , Jun Zhu , Luyao Wang , Lei Xing

Accelerated MRI reconstructs images of clinical anatomies from sparsely sampled signal data to reduce patient scan times. While recent works have leveraged deep learning to accomplish this task, such approaches have often only been explored…

Image and Video Processing · Electrical Eng. & Systems 2022-12-01 Michael S. Yao , Michael S. Hansen

Cone-beam computed tomography (CBCT) has become an invaluable imaging modality in dentistry, enabling 3D visualization of teeth and surrounding structures for diagnosis and treatment planning. Automated segmentation of dental structures in…

Computer Vision and Pattern Recognition · Computer Science 2025-08-19 Dominic LaBella , Keshav Jha , Jared Robbins , Esther Yu

A central problem in the field of radiation therapy (RT) is how to optimally deliver dose to a patient in a way that fully accounts for anatomical position changes over time. As current RT is a static process, where beam intensities are…

Medical Physics · Physics 2019-09-04 Rodney D. Wiersma , Xinmin Liu

Deep-neural-network-based image reconstruction has demonstrated promising performance in medical imaging for under-sampled and low-dose scenarios. However, it requires large amount of memory and extensive time for the training. It is…

Computer Vision and Pattern Recognition · Computer Science 2019-06-12 Dufan Wu , Kyungsang Kim , Quanzheng Li

Dual-energy computed tomography (DECT) has shown great potential and promising applications in advanced imaging fields for its capabilities of material decomposition. However, image reconstructions and decompositions under sparse views…

Medical Physics · Physics 2016-08-01 Lei Li , Ailong Cai , Linyuan Wang , Bin Yan , Hanming Zhang , Zhizhong Zheng , Wenkun Zhang , Wanli Lu , Guoen Hu
‹ Prev 1 3 4 5 6 7 10 Next ›