English
Related papers

Related papers: Updated parameters of the LArQL model

200 papers

Experimental data shows that both ionization charge and scintillation light in LAr depend on the deposited energy density ($dE/dx$) and electric field ($\mathcal{E}$). Moreover, free ionization charge and scintillation light are…

Instrumentation and Detectors · Physics 2022-07-19 F. Marinho , L. Paulucci , D. Totani , F. Cavanna

Liquid argon is used as active medium in a variety of neutrino and Dark Matter experiments thanks to its excellent properties of charge yield and transport and as a scintillator. Liquid argon scintillation photons are emitted in a narrow…

Instrumentation and Detectors · Physics 2021-02-10 Ettore Segreto

The $3 \times 1 \times 1$ m$^3$ demonstrator is a dual phase liquid argon time projection chamber that has recorded cosmic rays events in 2017 at CERN. The light signal in these detectors is crucial to provide precise timing capabilities.…

Instrumentation and Detectors · Physics 2021-03-24 B. Aimard , L. Aizawa , C. Alt , J. Asaadi , M. Auger , V. Aushev , D. Autiero , A. Balaceanu , G. Balik , L. Balleyguier , E. Bechetoille , D. Belver , A. M. Blebea-Apostu , S. Bolognesi , S. Bordoni , N. Bourgeois , B. Bourguille , J. Bremer , G. Brown , G. Brunetti , L. Brunetti , D. Caiulo , M. Calin , E. Calvo , M. Campanelli , K. Cankocak , C. Cantini , B. Carlus , B. M. Cautisanu , M. Chalifour , A. Chappuis , N. Charitonidis , A. Chatterjee , A. Chiriacescuf , P. Chiu , S. Conforti , P. Cotte , P. Crivelli , C. Cuesta , J. Dawson , I. De Bonis , C. De La Taille , A. Delbart , S. Di Luise , F. Doizon , C. Drancourt , D. Duchesneau , F. Dulucq , F. Duval , S. Emery , A. Ereditato , A. Falcone , K. Fusshoeller , A. Gallego-Ros , V. Galymov , N. Geffroy , A. Gendotti , A. Gherghel-Lascu , I. Gil-Botella , C. Girerd , M. C. Gomoiu , P. Gorodetzky , E. Hamada , R. Hanni , T. Hasegawa , A. Holin , S. Horikawa , M. Ikeno , S. Jiménez , A. Jipa , M. Karolak , Y. Karyotakis , S. Kasai , K. Kasami , T. Kishishita , H. Konari , I. Kreslo , D. Kryn , P. Kunzé , M. Kurokawa , Y. Kuromori , C. Lastoria , I. Lazanu , G. Lehmann-Miotto , M. Leyton , N. Lira , K. Loo , D. Lorca , P. Lutz , T. Lux , J. Maalampi , G. Maire , M. Maki , L. Manenti , R. M. Margineanu , J. Marteau , G. Martin-Chassard , H. Mathez , E. Mazzucato , G. Misitano , D. Mladenov , L. Molina Bueno , T. S. Mosu , W. Mu , S. Murphy , K. Nakayoshi , S. Narita , D. Navas-Nicolás , K. Negishi , M. Nessi , M. Niculescu-Oglinzanu , F. Noto , A. Noury , Y. Onishchuk , C. Palomares , M. Parvu , T. Patzak , Y. Penichot , E. Pennacchio , L. Periale , H. Pessard , F. Pietropaolo , D. Pugnere , B. Radics , D. Redondo , C. Regenfus , A. Remoto , F. Resnati , O. Ristea , A. Rubbia , A. Saftoiu , K. Sakashita , F. Sanchez , C. Santos , A. Scarpelli , C. Schloesser , K. Sendai , F. Sergiampietri , S. Shahsavarani , M. Shoji , J. Sinclair , J. Soto-Oton , D. I. Stanca , D. Stefan , R. Sulej , M. Tanaka , V. Toboaru , A. Tonazzo , W. Tromeur , W. H. Trzaska , T. Uchida , L. Urda , F. Vannucci , G. Vasseur , A. Verdugo , T. Viant , S. Vihonen , S. Vilalte , M. Weber , S. Wu , J. Yu , L. Zambelli , M. Zito

We have measured the scintillation and ionization yield of recoiling nuclei in liquid argon as a function of applied electric field by exposing a dual-phase liquid argon time projection chamber (LAr-TPC) to a low energy pulsed narrow band…

A particle detection system that exploits the scintillation light produced by ionizing particles in liquid argon (LAr) has been assembled at CERN. The system is based on 10 large-area photomultiplier tubes (PMT) immersed in a 1500-liter…

The scintillation yield for recoil Ar ions of 5 to 250 keV energy in liquid argon have been evaluated for direct dark matter searches. Lindhard theory is taken for estimating nuclear quenching. A theoretical model based on a biexcitonic…

Instrumentation and Detectors · Physics 2019-03-15 Akira Hitachi , A. Mozumder

A dedicated test of the effects of Oxygen contamination in liquid Argon has been performed at the INFN-Gran Sasso Laboratory (LNGS, Italy) within the WArP R&D program. Two detectors have been used: the WArP 2.3 lt prototype and a small (0.7…

Scintillation light, produced alongside ionisation charge from particle interactions, plays a critical role in liquid argon time projection chamber (LArTPC) detectors. A detailed understanding of its production and detection mechanisms is…

Instrumentation and Detectors · Physics 2026-03-26 MicroBooNE collaboration , P. Abratenko , D. Andrade Aldana , L. Arellano , J. Asaadi , A. Ashkenazi , S. Balasubramanian , B. Baller , A. Barnard , G. Barr , D. Barrow , J. Barrow , V. Basque , J. Bateman , B. Behera , O. Benevides Rodrigues , S. Berkman , A. Bhat , M. Bhattacharya , V. Bhelande , A. Binau , M. Bishai , A. Blake , B. Bogart , T. Bolton , M. B. Brunetti , L. Camilleri , D. Caratelli , F. Cavanna , G. Cerati , A. Chappell , Y. Chen , J. M. Conrad , M. Convery , L. Cooper-Troendle , J. I. Crespo-Anadon , R. Cross , M. Del Tutto , S. R. Dennis , P. Detje , R. Diurba , Z. Djurcic , K. Duffy , S. Dytman , B. Eberly , P. Englezos , A. Ereditato , J. J. Evans , C. Fang , B. T. Fleming , W. Foreman , D. Franco , A. P. Furmanski , F. Gao , D. Garcia-Gamez , S. Gardiner , G. Ge , S. Gollapinni , E. Gramellini , P. Green , H. Greenlee , L. Gu , W. Gu , R. Guenette , L. Hagaman , M. D. Handley , O. Hen , A. Hergenhan , M. Harrison , S. Hawkins , C. Hilgenberg , G. A. Horton-Smith , A. Hussain , B. Irwin , M. S. Ismail , C. James , X. Ji , J. H. Jo , A. Johnson , R. A. Johnson , D. Kalra , G. Karagiorgi , W. Ketchum , A. Kelly , M. Kirby , T. Kobilarcik , K. Kumar , N. Lane , J. -Y. Li , Y. Li , K. Lin , B. R. Littlejohn , L. Liu , S. Liu , W. C. Louis , X. Luo , T. Mahmud , N. Majeed , C. Mariani , J. Marshall , D. A. Martinez Caicedo , F. Martinez Lopez , M. G. Manuel Alves , S. Martynenko , A. Mastbaum , I. Mawby , N. McConkey , B. McConnell , L. Mellet , J. Mendez , J. Micallef , T. Mohayai , A. Mogan , M. Mooney , A. F. Moor , C. D. Moore , L. Mora Lepin , M. A. Hernandez Morquecho , M. M. Moudgalya , S. Mulleria Babu , D. Naples , A. Navrer-Agasson , N. Nayak , M. Nebot-Guinot , C. Nguyen , L. Nguyen , J. Nowak , N. Oza , O. Palamara , N. Pallat , V. Paolone , A. Papadopoulou , V. Papavassiliou , H. Parkinson , S. F. Pate , N. Patel , Z. Pavlovic , E. Piasetzky , K. Pletcher , I. Pophale , X. Qian , J. L. Raaf , V. Radeka , A. Rafique , R. Raymond , M. Reggiani-Guzzo , J. Rodriguez Rondon , M. Rosenberg , M. Ross-Lonergan , I. Safa , C. Sauer , D. W. Schmitz , A. Schukraft , W. Seligman , M. H. Shaevitz , R. Sharankova , J. Shi , L. Silva , E. L. Snider , S. Soldner-Rembold , J. Spitz , M. Stancari , J. St. John , T. Strauss , A. M. Szelc , N. Taniuchi , K. Terao , C. Thorpe , D. Torbunov , D. Totani , M. Toups , A. Trettin , Y. -T. Tsai , J. Tyler , M. A. Uchida , T. Usher , B. Viren , J. Wang , L. Wang , M. Weber , H. Wei , A. J. White , S. Wolbers , T. Wongjirad , K. Wresilo , W. Wu , E. Yandel , T. Yang , L. E. Yates , H. W. Yu , G. P. Zeller , J. Zennamo , C. Zhang , Y. Zhang

We report on a measurement of the attenuation length for the scintillation light in the tonne size liquid argon target of the ArDM dark matter experiment. The data was recorded in the first underground operation of the experiment in…

We measure the liquid argon scintillation response to electronic recoils in the energy range of $2.82$ to $1274.6~{\rm keV}$ at null electric field. The single-phase detector with a large optical coverage used in this measurement yields…

Instrumentation and Detectors · Physics 2020-11-25 M. Kimura , K. Aoyama , M. Tanaka , K. Yorita

For the future neutrino oscillation experiment DUNE, liquid argon time projections chambers with a fiducial mass of 10 kton each are foreseen. The dual phase concept is one of the two implementations considered, wherein electrons produced…

Instrumentation and Detectors · Physics 2019-05-22 T. Lux

Understanding liquid xenon scintillation and ionization processes is of great interest to improve analysis methods in current and future detectors. In this paper, we investigate the dynamics of the scintillation process for excitation by…

Instrumentation and Detectors · Physics 2022-11-08 Dominick Cichon , Guillaume Eurin , Florian Jörg , Teresa Marrodán Undagoitia , Natascha Rupp

Experiments searching for weak interacting massive particles with noble gases such as liquid argon require very low detection thresholds for nuclear recoils. A determination of the scintillation efficiency is crucial to quantify the…

Instrumentation and Detectors · Physics 2015-09-02 W. Creus , Y. Allkofer , C. Amsler , A. D. Ferella , J. Rochet , L. Scotto-Lavina , M. Walter

The scintillation light of liquid argon has been recorded wavelength and time resolved with very good statistics in a wavelength interval ranging from 118 nm through 970 nm. Three different ion beams, protons, sulfur ions and gold ions,…

Instrumentation and Detectors · Physics 2015-11-25 M. Hofmann , T. Dandl , T. Heindl , A. Neumeier , L. Oberauer , W. Potzel , S. Roth , S. Schönert , J. Wieser , A. Ulrich

A small-scale, two-phase (liquid/gas) xenon time projection chamber (Xurich II) was designed, constructed and is under operation at the University of Zurich. Its main purpose is to investigate the microphysics of particle interactions in…

Instrumentation and Methods for Astrophysics · Physics 2018-05-23 Laura Baudis , Yanina Biondi , Chiara Capelli , Michelle Galloway , Shingo Kazama , Alexander Kish , Payam Pakarha , Francesco Piastra , Julien Wulf

A spectroscopic study of liquid argon from the vacuum ultraviolet at 110 nm to 1000 nm is presented. Excitation was performed using continuous and pulsed 12 keV electron beams. The emission is dominated by the analogue of the so called 2nd…

Instrumentation and Detectors · Physics 2015-11-25 T. Heindl , T. Dandl , M. Hofmann , R. Krücken , L. Oberauer , W. Potzel , J. Wieser , A. Ulrich

In order to assess the performance of liquid xenon detectors for use in positron emission tomography we studied the scintillation light and ionization charge produced by 511 keV photons in a small prototype detector. Scintillation light was…

Instrumentation and Detectors · Physics 2009-09-24 P. Amaudruz , D. Bryman , L. Kurchaninov , P. Lu , C. Marshal , J. P. Martin , A. Muennich , F. Retiere , A. Sher

ArDM is a new-generation WIMP detector which will measure simultaneously light and charge from scintillation and ionization of liquid argon. Our goal is to construct, characterize and operate a 1 ton liquid argon underground detector. The…

Instrumentation and Detectors · Physics 2015-05-13 Vittorio Boccone

Scintillation light is used in liquid argon (LAr) neutrino detectors to provide a trigger signal, veto information against cosmic rays, and absolute event timing. In this work, we discuss additional opportunities offered by detectors with…

Instrumentation and Detectors · Physics 2015-01-27 M. Sorel
‹ Prev 1 2 3 10 Next ›