Ring artifacts in computed tomography images, arising from the undesirable responses of detector units, significantly degrade image quality and diagnostic reliability. To address this challenge, we propose a dual-domain regularization model…
Inconsistent responses of X-ray detector elements lead to stripe artifacts in the sinogram data, which manifest as ring artifacts in the reconstructed CT images, severely degrading image quality. This paper proposes a method for correcting…
Defective and inconsistent responses in CT detectors can cause ring and streak artifacts in the reconstructed images, making them unusable for clinical purposes. In recent years, several ring artifact reduction solutions have been proposed…
X-ray computed tomography (CT) is widely utilized in the medical, industrial, and other fields to nondestructively generate three-dimensional structural images of objects. However, CT images are often affected by various artifacts, with…
We present a pixel-specific, measurement-driven correction that effectively minimizes errors in detector response that give rise to the ring artifacts commonly seen in X-ray computed tomography (CT) scans. This correction is easy to…
Ring artifacts in X-ray micro-CT images are one of the primary causes of concern in their accurate visual interpretation and quantitative analysis. The geometry of X-ray micro-CT scanners is similar to the medical CT machines, except the…
Photon-counting spectral computed tomography is now clinically available. These new detectors come with the promise of higher contrast-to-noise ratio and spatial resolution and improved low-dose imaging. However, one important design…
Spectral computed tomography has received considerable interest in recent years since spectral measurements contain much richer information about the object of interest. In spectral computed tomography, we are interested in the energy…
High density implants such as metals often lead to serious artifacts in the reconstructed CT images which hampers the accuracy of image based diagnosis and treatment planning. In this paper, we propose a novel wavelet frame based CT image…
Artifacts on magnetic resonance scans are a serious challenge for both radiologists and computer-aided diagnosis systems. Most commonly, artifacts are caused by motion of the patients, but can also arise from device-specific abnormalities…
Gibbs-ringing is a well known artifact which manifests itself as spurious oscillations in the vicinity of sharp image transients, e.g. at tissue boundaries. The origin can be seen in the truncation of k-space during MRI data-acquisition.…
Classical methods for X-ray computed tomography are based on the assumption that the X-ray source intensity is known, but in practice, the intensity is measured and hence uncertain. Under normal operating conditions, when the exposure time…
Metal streak artifacts in X-ray computerized tomography (CT) are rigorously characterized here using the notion of the wavefront set from microlocal analysis. The metal artifacts are caused mainly from the mismatch of the forward model of…
The purpose of this work is to provide a fast and accurate scatter artifacts correction algorithm for cone beam CT (CBCT) imaging. The method starts with an estimation of coarse scatter profiles for a set of CBCT data in either image domain…
In Cone-Beam CT (CBCT) imaging systems, the scattering phenomenon has a significant impact on the reconstructed image and is a long-lasting research topic on CBCT. In this paper, we propose a simple, novel and fast approach for mitigating…
Metal objects pose a significant challenge in cone-beam computed tomography, as their strong and energy-dependent X-ray attenuation leads to inconsistent projections and severe streaking and shading artifacts in reconstructed images. These…
Purpose: To develop a simple and robust tool for the estimation of gradient delays from highly undersampled radial k-space data. Theory: In radial imaging gradient delays induce parallel and orthogonal trajectory shifts, which can be…
With the emergence of CNT (Carbon nanotube), static and instant CT scanning becomes possible. By transforming the traditionally rotated thermal source into a static ring array source composed of multiple CNTs, the imaging system can achieve…
A conventional approach to computed tomography (CT) or cone beam CT (CBCT) metal artifact reduction is to replace the X-ray projection data within the metal trace with synthesized data. However, existing projection or sinogram completion…
Ring artifacts are prevalent in 3D cone-beam computed tomography (CBCT) due to non-ideal responses of X-ray detectors, substantially affecting image quality and diagnostic reliability. Existing state-of-the-art (SOTA) ring artifact…