English
Related papers

Related papers: AC-LGADs Fermilab Front-End Electronics Characteri…

200 papers

A readout electronic with high time and energy resolution performance is designed for the SDD (Silicon Drift Detector) signals readout, which is aimed for X-ray pulsar based navigation (XNAV). For time measurement, the input signal is fed…

Instrumentation and Detectors · Physics 2016-03-10 Er-Lei Chen , Chang-Qing Feng , Chun-Feng Ye , Shu-Bin Liu , Dong-Dong Jin , Jian Lian , Hui-Jun Hu

This paper summarizes the beam test results obtained with a Resistive Silicon Detector (RSD) (also called AC-Low Gain Avalanche Diode, AC-LGAD) pixel array tested at the DESY beam test facility with a 5 GeV/c electron beam. Furthermore, it…

Precision timing has played a critical role in high-energy physics experiments, particularly for particle identification and the suppression of pileup under the challenging conditions expected at future colliders like the High-Luminosity…

Instrumentation and Detectors · Physics 2026-03-31 Martina Malberti , Xiaohu Sun

The multi-pad PICOSEC-Micromegas is an improved detector prototype with a segmented anode, consisting of 19 hexagonal pads. Detailed studies are performed with data collected in a muon beam over four representative pads. We demonstrate that…

Three Gas-Electron-Multiplier tracking detectors with an active area of 10 cm x 10 cm and a two-dimensional, laser-etched orthogonal strip readout have been tested extensively in particle beams at the Meson Test Beam Facility at Fermilab.…

A backside-illuminated (BSI) near-infrared enhanced silicon single-photon avalanche diode (SPAD) for time-of-flight (ToF) light detection and ranging applications is presented. The detector contains a 2 $\mu$m wide multiplication region…

Instrumentation and Detectors · Physics 2022-03-04 Edward Van Sieleghem , Gauri Karve , Koen De Munck , Andrea Vinci , Celso Cavaco , Andreas Süss , Chris Van Hoof , Jiwon Lee

High-resolution 3D tracking with sub-nanosecond timing is required for the detection of elementary particles, such as neutrinos. Conventional detectors, which utilize analog silicon photomultipliers, face challenges in balancing spatial…

Instrumentation and Detectors · Physics 2025-11-24 Kodai Kaneyasu , Till Dieminger , Matthew Franks , Davide Sgalaberna , Claudio Bruschini , Edoardo Charbon

A new generation of high-resolution hypernuclear gamma$-spectroscopy experiments with high-purity germanium detectors (HPGe) are presently designed at the FINUDA spectrometer at DAPhiNE, the Frascati phi-factory, and at PANDA, the…

To probe physics of interest a decade after the LHC begins to take data, the Linear Collider will need to have the capability of performing precision measurements of masses and couplings. We discuss the demands that this places on its…

Instrumentation and Detectors · Physics 2007-05-23 Bruce A. Schumm

The ATLAS Forward Physics (AFP) project plans to install 3D silicon pixel detectors about 210 m away from the interaction point and very close to the beamline (2-3 mm). This implies the need of slim edges of about 100-200 $\mu$m width for…

Instrumentation and Detectors · Physics 2015-11-09 Jörn Lange , Emanuele Cavallaro , Sebastian Grinstein , Ivan Lopez Paz

Novel electronic devices can often be operated in a plethora of ways, which makes testing circuits comprised of them difficult. Often, no single tool can simultaneously analyze the operating margins, maximum speed, and failure modes of a…

Instrumentation and Detectors · Physics 2025-09-11 Reed A. Foster , Stephen Kandeh , Owen Medeiros , Alejandro Simon , Matteo Castellani , Karl K. Berggren

The CALICE collaboration is involved in the design of compact calorimeters featuring a high granularity. The technical developments have to overcome various design issues such as the power dissipation, the integration of the front-end…

Instrumentation and Detectors · Physics 2009-02-02 Remi Cornat

We are developing position sensitive silicon detectors (PSDs) which have an electrode at each of four corners so that incident position of a charged particle can be obtained with signal from the electrodes. It is expected that the position…

Instrumentation and Detectors · Physics 2020-05-28 Y. Uesugi , R. Mori , H. Yamashiro , T. Suehara , T. Yoshioka , K. Kawagoe

The current state of the art in fast timing resolution for existing experiments is of the order of 100 ps on the time of arrival of both charged particles and electromagnetic showers. Current R&D on charged particle timing is approaching…

The reconstruction software for ILD is currently subject to a major revision, aiming at improving its accuracy, speed, efficiency and maintainability in time for the upcoming DBD Report. This requires replacing old code by novel methods for…

Data Analysis, Statistics and Probability · Physics 2012-02-14 Robin Glattauer , Rudolf Frühwirth , Jakob Lettenbichler , Winfried Mitaroff

A MHz frame rate X-ray area detector (LPD - Large Pixel Detector) is under development by the Rutherford Appleton Laboratory for the European XFEL. The detector will have 1 million pixels and allows analogue storage of 512 images taken at…

We demonstrate the imaging capability of a frequency modulated continuous wave lidar based on a fiber bundle. The lidar constructs velocity and range images for hard targets at a rate of 60 Hz. The sensing range is up to 30 m with 20 mW of…

Instrumentation and Detectors · Physics 2024-10-28 Iskander Gazizov , Sergei Zenevich , Alexander Rodin

Radiation hard helium gas ionization chambers capable of operating in vacuum at temperatures ranging from 5K to 350K have been designed, fabricated and tested and will be used inside the cryostats at Fermilab's Superconducting…

Accelerator Physics · Physics 2012-10-01 A. Warner , J. Wu

The agreement between calculations inspired by the resummation of energy logarithms, known as BFKL approach, and experimental data in the semi-hard sector of QCD has become manifest after a wealthy series of phenomenological analyses.…

High Energy Physics - Phenomenology · Physics 2021-09-09 Francesco Giovanni Celiberto

The High-Acceptance DiElectron Spectrometer (HADES) at GSI Darmstadt consists of a 6-coil toroidal magnet centered on the beam axis and six identical detection sections located between the coils and covering polar angles between $18^\circ$…

Instrumentation and Detectors · Physics 2023-04-05 A. Blanco , P. Fonte , L. Lopes , J. Saraiva
‹ Prev 1 8 9 10 Next ›